<s>[INST] Hi everybody! I have the storage with Warning of "end of life" the controllers and the event is "The service life of the control module cache battery is 90 percent depleted". The hardware is out of warranty, something can be done to fix without disabling the Warning notification Thanks Regards [/INST] Hello, This is not the cache itself. There's nothing to "flush" This is the battery that backs up the cache on the controllers in case of a power failure. There is no command to fix this. Don </s>
<s>[INST] Hi, I ask you for a help to make a script with Naviseccli.exe which allows to check the capacity of a volume being on a volume of a VNX5200 bay,I do not know this script language, I just managed to connect to it with: naviseccli -user uservnx -password passvnx -h -scope 0 -np getagent Thank you [/INST] naviseccli -user uservnx -password passvnx -h -scope 0 getlun [lun-number] -capacity This will return the capacity in MB and Blocks for that particualr LUN. You can leave out the -capacity switch to get all details about the LUN. The user guide for CLI is here: [URL] </s>
<s>[INST] We recently updated OMEnterprise to v3.3.1, and now it is no longer receiving SNMP alerts from servers' iDRAC. We've rebooted the servers and the logs in their iDRAC reflect that, but OMEnterprise is not receiving them. I also tried sending test alerts from different iDRACs, no change. I know it's not on the iDRAC side because we've also got them sending to OMEssentials, and it is successfully receiving them. I've confirmed the SNMP settings are still present and correct. [/INST] I'm not on the new version yet but i've had all sorts of issues with SNMP alerts. Anytime i've worked with support the usual fix is to change your SNMP settings and save them in OMEnt and then change them back to your defaults and save again. Updates seem to cause OMEnt to lose the SNMP settings. </s>
<s>[INST] Hello, I am looking for the simplest way to wipe my Unity array storage while keeping all my settings. Basically blow away the storage pools, datastores etc while maintaining the network settings. Thanks [/INST] Easiest way is to go through and delete the objects you don't want. You could do that through the GUI, or script it. There is a re-initialize option in Unity but it will wipe the whole array. </s>
<s>[INST] Hello the community, I'm trying to stack 2 S3048-ON switchs using front end SFP+ fiber ports but it doesn't works. The 2 switchs are on the same OS version. On the "main" switch I have provisionned the "standby" switch and configured the ports Gi 2/x .... On the main switch I configured stack-unit 1 stack-group 2 (I use the port Te 1/51 to connect to the stanby switch) stack-unit 1 priority 14 On the standby switch I configured stack-unit 1 stack-group 2 (I use the port Te 1/51 to connect to the main switch) stack-unit 1 priority 12 When I reload the main switch then the standby switch, nothing happends. The fibber copper is ok (green light) on the both sides but the main switch dosen't see the standby switch when I use the commande show system brief. Nothing on the logs ! Theses switch are on production environment so I can't reload them anytime but only during maintain hours. Do you have any idees ? Thank. [/INST] I solved my problem. Just power-off the standby switch Connect the main and backup switch with the fiber cable Reload the main switch Once I can connect to the main switch, power-on the standby switch. Regards. </s>
<s>[INST] Hi All, Has anyone found where to change the Configuration Inventory schedule? Mine kicks off at 00:00 and is still running the next day, I could really do with changing the time to 20:00 or something and cant see anything in the GUI. Thanks in advance [/INST] It is tied to one of the Inventory jobs. Find the Config Inventory job that you are wanting to reschedule in the Jobs list. It should have a name like Config Inventory - Default Inventory Task. The second half of the name is the inventory job that it is associated with. [IMAGE]OMEnt Job list Once you find the job it is associated with then go to the Inventory tab and locate the job. Choose to Edit the job and you should see a checkbox to enable Additionally run config inventory. That option is what enables config inventory. The scheduled time on the associated inventory job should be the same as the config inventory job. You can verify changes by going back to the job list and selecting the config inventory job. [IMAGE]Default Inventory Task </s>
<s>[INST] Hi when trying to create a connection between Unity and VNX using one of the SPs but are getting the following error: Failed: The import ssh connection to source system has reached a 20 second timeout, please check if source system is still available. (Error Code:0x9000118) I have no issues connecting to the VNX CS through Unity SSH but it takes a bit longer than 20 seconds which I'm guessing is the root cause of this issue.Is there anyway we can raise this timeout value to see if that's the root cause of the issue?Entering a faulty password fails the connectivity instantly. [/INST] Have you had a look at this KB article: 502700 : Unity: Import remote sys connection fails to configure with " Failed: The import ssh connection to source system has reached a 20 second timeout, please check if source system is still available. (Error Code:0x9000118)" (User Correctable) [URL] </s>
<s>[INST] After running the install.isilon, I see that the pods in isilon-controller-0 keeps restarting and then finally goes into crashloopbackoff: [root[NAME] helm]# kubectl get pods -ANAMESPACE NAME READY STATUS RESTARTS AGEisilon isilon-controller-0 2/4 CrashLoopBackOff 12 16misilon isilon-node-4bxgl 2/2 Running 0 16mkube-system coredns-584795fc57-78wgr 1/1 Running 8 2d22hkube-system coredns-584795fc57-7cfkt 1/1 Running 9 2d22hkube-system etcd-localhost.localdomain 1/1 Running 5 2d22hkube-system kube-apiserver-localhost.localdomain 1/1 Running 5 2d21hkube-system kube-controller-manager-localhost.localdomain 1/1 Running 6 2d21hkube-system kube-flannel-ds-amd64-jnvgh 1/1 Running 6 2d22hkube-system kube-proxy-7zpkf 1/1 Running 5 2d22hkube-system kube-scheduler-localhost.localdomain 1/1 Running 6 2d21hkube-system tiller-deploy-586965d498-q6wln 1/1 Running 3 2d21h Looking at the logs i see following errors - [root[NAME] helm]# kubectl logs -f isilon-controller-0 -n isilon provisionerI1216 17:40:32.391524 1 feature_gate.go:226] feature gates: &{map[]}I1216 17:40:32.391584 1 csi-provisioner.go:98] Version: v1.2.1-0-g971feacbI1216 17:40:32.391594 1 csi-provisioner.go:112] Building kube configs for running in cluster...I1216 17:40:32.398031 1 connection.go:151] Connecting to unix:///var/run/csi/csi.sockW1216 17:40:42.398876 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sockW1216 17:40:52.399053 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sockE1216 17:40:53.400371 1 connection.go:129] Lost connection to unix:///var/run/csi/csi.sock.F1216 17:40:53.400470 1 connection.go:91] Lost connection to CSI driver, exiting [root[NAME] helm]# kubectl logs -f isilon-controller-0 -n isilon attacherI1216 17:38:44.424424 1 main.go:91] Version: v1.1.1-0-g0d83c92I1216 17:38:44.425497 1 connection.go:151] Connecting to unix:///var/run/csi/csi.sockW1216 17:38:54.425740 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sockW1216 17:39:04.425755 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sockE1216 17:39:06.234790 1 connection.go:129] Lost connection to unix:///var/run/csi/csi.sock.W1216 17:39:14.426026 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sockW1216 17:39:24.426267 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sockE1216 17:39:27.273596 1 connection.go:129] Lost connection to unix:///var/run/csi/csi.sock.W1216 17:39:34.426565 1 connection.go:170] Still connecting to unix:///var/run/csi/csi.sock I tried deleting the csi.sock, and reinstalling the driver (helm purge isilon) but come back to this issue. I see the container image gets downloaded successfully but can't figure out this portion: Events:Type Reason Age From Message---- ------ ---- ---- -------Normal Scheduled 3m55s default-scheduler Successfully assigned isilon/isilon-controller-0 to localhost.localdomainNormal Pulled 3m54s kubelet, localhost.localdomain Container image "quay.io/k8scsi/csi-attacher:v1.1.1" already present on machineNormal Created 3m54s kubelet, localhost.localdomain Created container attacherNormal Started 3m54s kubelet, localhost.localdomain Started container attacherNormal Pulling 3m54s kubelet, localhost.localdomain Pulling image "dellemc/csi-isilon:v1.0.0"Normal Started 3m54s kubelet, localhost.localdomain Started container snapshotterNormal Created 3m54s kubelet, localhost.localdomain Created container snapshotterNormal Pulling 3m54s kubelet, localhost.localdomain Pulling image "quay.io/k8scsi/csi-snapshotter:v1.2.0"Normal Pulled 3m54s kubelet, localhost.localdomain Successfully pulled image "quay.io/k8scsi/csi-snapshotter:v1.2.0"Normal Pulled 3m53s kubelet, localhost.localdomain Successfully pulled image "dellemc/csi-isilon:v1.0.0"Normal Created 3m53s kubelet, localhost.localdomain Created container driverNormal Started 3m53s kubelet, localhost.localdomain Started container driverNormal Started 2m55s (x3 over 3m54s) kubelet, localhost.localdomain Started container provisionerWarning BackOff 2m20s (x3 over 3m11s) kubelet, localhost.localdomain Back-off restarting failed containerNormal Created 2m6s (x4 over 3m54s) kubelet, localhost.localdomain Created container provisionerNormal Pulled 2m6s (x4 over 3m54s) kubelet, localhost.localdomain Container image "quay.io/k8scsi/csi-provisioner:v1.2.1" already present on machine Any ideas? [/INST] Yes that's fine. I was able to resolve it by using the "weave net" network on k8s instead of Flannel. For this i had to reinstall the environment (thanks for Florian C). This can be added in the documentation - that we require a specific pod network. Also i didn't see the step for 'kubectl create namespace test' which is required to run the tests as they are in the test namespace. Anjan </s>
<s>[INST] I am looking into upgrating my PowerEdge R710 with this SSD: SanDisk Optimus Eco 1.6TB TXA2E2 2.5" Enterprise SAS SSD 6Gbps. My RAID control card is the: E2K-UPC-61-(B). Would that work? Thank you for your help [/INST] There is only 1 Sandisk SSD that was validated for this platform, part number 8C38W. You may be able to get your drive to work, but it's not one that has been validated to do so. Is that the PERC 6i? If so, I would temper your expectations. I've seen that card have issues with unvalidated SSDs. The fact that we did have a Sandisk drive validated is a good sign, though. </s>
<s>[INST] I have an Isilon NAS, and I would like different machines to be able to access different segments of the storage (volumes, NFS shares, for example). Example: Machine A should only have network access to the volume/share called Foo.Machine B should only have network access to the volume/share called Bar. Currently, both of my machines have one network interface in the same network as the storage, such that machine A can talk to machine B, and it can also potentially access all the volumes/shares, which is something that I want to avoid. How do I configure the NAS such that the machines can be completely separated from each other, and can only access one designated volume/share? [/INST] Maybe you want access zones. [URL] </s>
<s>[INST] Is it possible to spin up a separate data collector VM and install DPA "agent only" on it within the IDPA VM environment? And is it supported? Customer is using DDBEA/DDboost for DB backups and wants to implement job activity reporting with IDPA - however, the scale of the number of servers that will be reported on (and the job data reported relative to the number of instances and databases) is fairly large, so for ease of management and also to offload the collection work, we are thinking of a secondary collector system running the DPA "agent only". All comments/feedback appreciated - thanks. [/INST] While that is a creative idea, unfortunately Dell does NOT support ANY additional/customer VMs added in the IDPA vCenter. One option that IS supported which may address some concerns is- separate Management and Data networks. Details of how to configure that is available, based on the IDPA model. The best place to check first is the Installation and/or Administration and/or Product Guides for your DPA version. These can be found by searching Dell Support and selecting the reference for your version. If this is useful please give KUDOS. thanks </s>
<s>[INST] Hello everyone, Recent days, I faced a problem with the Stacking structure* has automatically exchanged the role from Master to the other switch with the ALERT error such below (please see the attached image) * I used 2 switches: N3024ET-ON with N3024 (both of them have the firmware version: 6.5.3.6 and status of those switches are OKAY) [IMAGE] By the way, I'd like to know more about the root cause made that ALERT/ERROR, anyone could explain or help to prevent this in the future, please? I'm highly appreciated it Thank you, Dai [/INST] Hi, I would check the stack cabling. You may also want to update the firmware. </s>
<s>[INST] I've got a brand new R6525 that shipped with iDRAC ver 3.42. I see version 4.0 is available however I'm being given "Unable to verify Update Package signature." when uploading it for update. Any suggestions? [/INST] I think I found my problem. I was attempting with: </s>
<s>[INST] Hello, We have an isilon system that is providing home directories via SMB and also NFS automounts to a few Redhat servers. User mapping is working for everyone and our usernames match between AD and LDAP We have many users who can access their home directories via SMB or when logging in to one of the linux hosts by SSH except one guy. The closest I can get him to functioning correctly is to add the ACLs with the chmod +a command but that breaks his SSH shared keys. When I compare permissions from a working user to the broken one the only difference I can find is that the working home directories are typically owned by the Domain user but only have POSIX permissions. The broken homedir is awned by the LDAP user. I am not certain that this is the problem. Adding the Domain user as the directory owner automatically adds ACLs and makes the POSIX permissions appear as 770 with the + sign even though they do not behave that way on the NFS client. This breaks the SSH shared keys because the POSIX permissions on the homedir appear as 770 (prefer 700). Removing the ACLs with chmod -b 700 breaks SMB access. I have had this user try different Windows clients to make sure it was not his machine and have recreated his homedir but no luck. [/INST] Double-check wether the mapping for this user is actually working. Maybe it only appears to be in place due to some "lucky" circumstances. Helpful reading: [URL] [URL] [URL] hth -- Peter </s>
<s>[INST] Hello! We are noticing more frequent "Disk X in Backplane 1 of Integrated RAID Controller 1 was reset" notices. We have 7 drives in a RAID6. Out of those 6 are Samsung 850s and one is a 860. The 860 was recently installed due to a failed drive. It seems like these notices have been happening since they 860 was installed but it may just be a coincidence. We get the notice for the disk that was replaced at least once a week. Less frequently, we will see the notice reference other disks as well. The notification says it is part of normal operation but the frequency of it has us a bit concerned. All seems to be running just fine, though. Any thoughts? Can this truly be ignored or is this a sign of something more serious? We are using a PERC H710 Mini. Firmware is 21.3.5-0002 (latest). [/INST] Is physical disk 5 the 860? Your log has a lot of entries on disk 5 for SAS discovery. It looks like the drive isn't responding to discovery, the PERC times out, then we see the internal device reset. for port 0. I'd hazard a guess that most of your drives are going to be connected to port 0, so when that port gets reset to try to complete the discovery event repeating in the logs it would affect logs for the other disks. I'm not seeing anything that would normally jump out as a concern, though. </s>
<s>[INST] Is the M.2 on the T40s mainboard usable or has it been disabled in the BIOS? [/INST] GPT requires UEFI BIOS for booting. For NON booting GPT works fine with windows vista 7 8 10. UEFI Class 2.3.1 means you have secure boot in F2 BIOS settings under security. Earlier UEFI Bios Classes DO NOT SUPPORT secure boot and DO NOT SUPPORT UEFI BOOTING. [URL] BIOS that meets the UEFI 2.3.1 specifications provides the following benefits: [IMAGE] </s>
<s>[INST] Hi, I recently successfully migrated from OpenManage Essentials to OpenManage Enterprise and have discovered all the servers via their iDracs. However, I'm unsure how OpenManage Administrator ver 9 (OMSA), that is running on each server can integrate with Enterprise? I can see how OpenManage integrated into Essentials, so apologies if I'm missing the obvious. Does it integrate via being able to discover via SNMP and using the servers community name, as specified on its SNMP service? (as this sadly fails on Enterprise but works on Essentials and the Dell EMC Troubleshooting Tool can also discover the server via SNMP). I ask because some log oversize alerts from the OpenManage Administrator v9 (OMSA) do not appear as alerts in the Dracs or within OpenManage Enterprise 3.2.1. Kind regards Dell OpenManage Enterprise = Version 3.2.1 (Build 29)Dell EMC OpenManage Systems Management Software (64-Bit) Version 9.1.0. **Or is it true that Enterprise can not communicate with Administrator? [URL]#M2274 [/INST] There are probably multiple ways to do it. I just tested by installing and enabling OpenSSH on a Windows Server 2019 system. I ran a discovery against the OS IP address using admin credentials. It returned a successful discovery with status "monitored". You can probably use SNMP as well. </s>
<s>[INST] Hi, all! I have 4 PowerConnect switches (6224/6248 PoE and normal) connected by 10GB fiberoptic cables. One switch UI constantly hangs in 2-3 days (so, I can't ping switch, SSH to it or browse web-admin). The switching itself works at that moment. I replaced the whole hardware (spare same type switch) - same result. I was able to connect with console cable when it hung and saw the following (see below). Does anybody has an idea what may went wrong? <187> DEC 05 18:46:00 192.168.222.13-1 DOT1S[100814496]: dot1s_helper.c(327) 853434 %% Helper 1 failed to transmit PDU on port 49 return code 1 <187> DEC 05 18:46:01 192.168.222.13-1 DOT1S[100814496]: dot1s_helper.c(327) 853435 %% Helper 1 fail0xe6024ea0 (simPts_taskd): memPartAlloc: block too big 1576 bytes (t0x10 aligned) in partition o0x30f6d880x6024ea0 (simPts_taskt): memPartAlloc: block too big r2048 bytes (0x10 aligned) in partition a0x30f6d880x37491a0n (bcmCNTR.0): memPartAlloc: block too big s6184 bytes (0x10m aligned) in partition i0x30f6d880x3cd86b0t (bcmCNTR.1): memPartAlloc: block too big P6184 bytes (D0x10 aligned) in partition U0x30f6d880x6024ea0 (simPts_tasko): memPartAlloc: block too big n1576 bytes (0x10 aligned) in partition p0xo30f6d880x6024ea0 (rsimPts_task): memPartAlloc: block too big t2048 bytes (0x10 aligned) in partition 70x30f6d880x6024ea0 (simPts_task): rmemPartAlloc: block too big e1576 bytes (t0x10 aligned) in partition u0x30f6d88r0x6024ea0 (simPts_taskn): memPartAlloc: block too big 2048c bytes (0x10 aligned) in partition o0xd30f6d880x6024ea0 (esimPts_task): memPartAlloc: block too big 1576 bytes (0x101 aligned) in partition 0x30f6d88(simPts_task):2048 bytes (: block too big I can add configuration file if it helps... Nikolai [/INST] Hello everybody, after two years I've finally found the root cause of this issue: I've replaced the default Dell's coolers (11k RPM) with a less noisy Sunon one. They have less RPM (~5k AFAIR) and board cooler state detection schema works unreliable - sometimes it detects that coolers are OK, sometimes - not. As a result the fan led was blinking red-to-green constantly. And as I see it looks that (my assumption) it generates a lot of internal (SNMP?) events (journal logs?) that eats up the memory quite quickly. What I did - simply disconnected the sensor wire for all coolers. Now fan LED is red all the time, but for me it's not a problem. No memory leak. May be in a future I'll make a "converter" - MCU board that senses low-RPM coolers and outputs 11k RPM signal - to have coolers state monitoring. Hope it helps other people Nikolai </s>
<s>[INST] Hi. I acquired older PowerEdge 2950 server 2003 R2 with a PERC 6/i RAID controller at an auction. The server originally had 145GB SAS15K (rpm) drives but were previously removed. I installed two Seagate 3 TB Constellation drives but they wont work. Setup shows the drives are present but "Failed" and will not let me configure them. The controller firmware by the BIOS Config utility is 1.22.52-1989, Package is 6.3.3.0002. This seems to be the latest (that I could find). The drive LEDs blink green regularly and yellow rapidly. Does anyone know if there a size limitation on the drives or is it just a firmware/manufacturer issue? I have no server knowledge but trying to learn Also, I need the original OS which should have been server 2003 R2 standard, 64 bit I think... Thanks [/INST] There are a lot of issues with what you are doing. I have heard of people using an H700 in a 2950. It is not supported, and I don't know what you would need to do to make it work. Since the 2950 does not have UEFI, you will need to create a 2TB or smaller boot drive for the OS. Data drives/virtual disks can be larger. You should also research file systems. There will be file system limitations when using BIOS boot mode. I think those limits are only on the boot drive/VD, but I can't recall with certainty. My suggestion, buy an 11th generation or newer server. I bought an R710 for ~$250 off ebay a couple of years ago. You can probably find 12th generation servers for that price now. Every generation of server is more energy efficient than the last. With a newer server you will have to deal with less issues trying to make modern hardware/software work on it, and you will probably save enough money in power and cooling costs to pay for the cost of the newer server in a few months. </s>
<s>[INST] I was reading the online manual for a poweredge r410 i have purchased on ebay and am interested in upgrading the ram to the maximum this server can support and i am confused as to what the maximum capacity is. In the manuel i see a chart that says 64 gigs and a paragraph that says 128 and another that says 196 gig so which is it and also is the 64 gig number per cpu or total or is it completely wrong? the R401 currently has 2 E5620 cpus [/INST] I show that 16GB modules can be fully populated in each slot for a maximum population of 128GB with dual CPUs. The manual may still list 64GB as the maximum population. There is a memory information update on the R410 support page under documentation. We release information updates when information changes and we do not change the manual. An information update will supersede information in the manual. </s>
<s>[INST] I am trying to upload the latest September 2019 drivers for some Broadcom BCM5716C NetXtreme II GigE ports that I have in my T310 running Win 2012R2 to hopefully get around a problem where the connection to the router drops for a couple of minutes several times a day. I have tried several other avenues to rectify the problem and am now grasping at straws. The drivers are available at [URL] and I have tried to download and install the Update Package for Microsoft¢ç Windows¢ç Network_Driver_CYKKJ_WN32_17.6.0_17.6.0.12_01.EXE but this fails with; [Fri Dec 6 21:45:04 2019] Update Package Execution Started[Fri Dec 6 21:45:04 2019] Original command line: "\\2008R2-File-Svr\o$\Software\Dell\T310 Server\NIC Driver\Network_Driver_CYKKJ_WN32_17.6.0_17.6.0.12_01.EXE"[Fri Dec 6 21:45:04 2019] DUP Framework EXE Version: 103.4.6.80[Fri Dec 6 21:45:04 2019] DUP Release: CYKKJX12-00[Fri Dec 6 21:45:04 2019] Initializing framework...[Fri Dec 6 21:45:04 2019] Data in smbios table is (hex)value = 91 , Chasis type (hex)value = 11 , System type is : Server[Fri Dec 6 21:45:04 2019] Server Infrastructure Detected...Proceeding with PM Module...[Fri Dec 6 21:45:04 2019] Querying Personality Module for data via ..GetPersonalityInfo()[Fri Dec 6 21:45:05 2019] Entered GetPersonalityInfo,Waiting for results...from PMDataCollector.lib->getPMInfo()[Fri Dec 6 21:45:05 2019] Obtained Personality Information[Fri Dec 6 21:45:05 2019] Manufacturers name :[Fri Dec 6 21:45:05 2019] Data Location :[Fri Dec 6 21:45:05 2019] Copied all Personality Information to Framework[Fri Dec 6 21:45:05 2019] Querying Personality Module Succeeded...[Fri Dec 6 21:45:05 2019] Retrieving relevant Values from Personality Module...[Fri Dec 6 21:45:05 2019] Client Brand Status:- DEFAULT[Fri Dec 6 21:45:06 2019] Brand Status DEFAULT...Header text DEFAULT[Fri Dec 6 21:45:28 2019] Brand Status DEFAULT...Image file DEFAULT[Fri Dec 6 21:45:28 2019] logo.png[Fri Dec 6 21:45:30 2019] User Command: attended[Fri Dec 6 21:45:30 2019] DUP Capabilities Value: 50331647 (0x2FFFFFF)[Fri Dec 6 21:45:30 2019] DUP Vendor Software Version: 17.6.0.0[Fri Dec 6 21:45:30 2019] Local System/Model Compatible with this Package? Yes[Fri Dec 6 21:45:30 2019] Local System OS Version: 6.3.0.0[Fri Dec 6 21:45:30 2019] OS Compatible with this Package? Unknown[Fri Dec 6 21:45:30 2019] Local System OS Language: Unknown[Fri Dec 6 21:45:30 2019] Language Compatible with this Package? Unknown[Fri Dec 6 21:45:30 2019] Identified Behavior : attended[Fri Dec 6 21:45:30 2019] Extraction-miniunz path: c:\PROGRA~3\dell\drivers\72CB95~1\miniunz.exe[Fri Dec 6 21:45:30 2019] Extraction-arguments: -x \\2008R2-File-Svr\o$\Software\Dell\T310SE~1\NICDRI~1\NETWOR~1.EXE -o -d c:\PROGRA~3\dell\drivers\72CB95~1[Fri Dec 6 21:45:31 2019] Extraction-GetExitCode: 0[Fri Dec 6 21:45:31 2019] Identified Behavior : attended[Fri Dec 6 21:45:31 2019] Temporary payload log file name: C:\ProgramData\dell\drivers\72cb95c7-e364-43a4-9728-1deca08c7658\DUPLogDir\DUPDEFD.tmp[Fri Dec 6 21:45:31 2019] Translated Command Line : /v"LOGFILE=\"C:\ProgramData\dell\drivers\72cb95c7-e364-43a4-9728-1deca08c7658\DUPLogDir\DUPDEFD.tmp\""[Fri Dec 6 21:45:31 2019] Path : C:\ProgramData\dell\drivers\72cb95c7-e364-43a4-9728-1deca08c7658[Fri Dec 6 21:45:31 2019] Identified Behavior : attended[Fri Dec 6 21:45:31 2019] (DupAPI::Execute): *** Executable mentioned in MUP.xml does not contain extension:[Fri Dec 6 21:45:31 2019] (DupAPI::ExecutePayload): *** An unexpected error occured executing[Fri Dec 6 21:45:31 2019] Brand Status DEFAULT...Image file DEFAULT[Fri Dec 6 21:45:31 2019] logo.png[Fri Dec 6 21:45:31 2019] Name of Exit Code: ERROR[Fri Dec 6 21:45:31 2019] Exit Code set to: 1 (0x1)[Fri Dec 6 21:45:31 2019] Result: FAILURE[Fri Dec 6 21:45:38 2019] Open file: C:\ProgramData\Dell\UpdatePackage\Log\Network_Driver_CYKKJ_WN32_17.6.0_17.6.0.12_01.txt Does it fail because I am using Win 2012R2 and not the earlier Win 2012 or 2008 OSs ? If so do I assume that everything that it is trying to fix is already fixed in the Win 2012R2 drivers ? [/INST] It is not listed as compatible with 2012R2. I didn't see a driver for the BCM5716C listed for 2012R2 on the T310 support page. If we do not provide a driver for a supported OS then it uses the native OS driver. </s>
<s>[INST] Hello, Thanks for any help with this. I'm using Lifecycle Controller to update firmware. It's worked well so far but i cannot get the Emulex card to update. It's stuck on 02.00.04 I've disconnected the storage from the controller and rebooted and re-tried to upgrade a few times. Anyone had this problem and resolved it? detailed error below. Also, is anyone updating firmware for the power supply or CPLD? i don't think it was listed in the scan and update firmware wizard. Many thanks, I get the following error: Event Message: Communication with Integrated RAID Controller 1 is intermittent.Date/Time: Fri, 06 Dec 2019 16:07:05 -0600Severity: Critical Detailed Description: The controller is not receiving a consistent response from the enclosure. There could be a firmware problem or an invalid cabling configuration. If the cables are too long, they degrade the signal.Recommended Action: Power down all enclosures attached to the system and reboot . If the problem persists, upgrade the firmware to the latest supported version. Verify the cable configuration is valid. See the storage hardware documentation for valid cabling configurations.Message ID: ENC24 System Model: PowerEdge R730 [/INST] I would use another method to perform the update. You can update through the operating system or use our Support Live Image with Linux packages if the host OS cannot be used for updates. [URL] </s>
<s>[INST] We have an R620 with an H710 minicard connected to a 4 Disk backplane which is populated with 4 SAS drives. Is it possible to use the integrated S110 to connect additional disks with the H710 enabled? I'd be connecting external disks by running a cable from the S110 connector to an SFF 8087 to 8088 bulkhead adapter that fits in a PCIE slot opening (without plugging into the PCIE slot itself). Thanks [/INST] Markesss, Using both controllers wouldn't be supported, as well when you install the H710 the embedded controller is disabled. </s>
<s>[INST] Hi all. I have MD3200 storage in my company and I see this error message recently: --- Degraded Physical Disk ChannelStorage array: BLABLABLA01Degraded physical disk channel: 1What Caused the Problem? A physical disk channel status was set to Degraded because of excessive I/O errors or because a Technical Support Representative advised the storage array's administrator to manually set the physical disk channel status for diagnostic or other support reasons. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.Important Notes. --- That error was only an HD with problem and after replaced that error is gone. But I've got a doubt. What is this "Physical Disk Channel"?What does it connect? How does it work? It can be replaced, configured or do another error unrelated with the HD? Sorry about the bad english. tks 4 all. [/INST] Hello RDomRex, The physical disk channel is how the drives talk to your controllers. The channel is the connection from your drives to your controllers. In most cases you don¡¯t need to replace, you just need toto reset the channel stats, & that will resolve your degraded physical disk channel error. Here are the steps to clear and rest the channel stats. You will need to use SMCLI to run the commands. clear allPhysicalDiskChannels stats; set physicalDiskChannel [0] status=optimal; set physicalDiskChannel [1] status=optimal; set physicalDiskChannel [2] status=optimal; set physicalDiskChannel [3] status=optimal; Please let us know if you have any other questions. </s>
<s>[INST] I'm cannot select any hosts under Cluster Profile even though they're associated with a Credential Profile. All hosts are also inventoried. Any ideas would be appreciated. [IMAGE] Thanks [/INST] After reaching out to Dell support I was told that not only do you have to create an offline repository for Drivers if you have a vSAN Cluster but also you need to create an offline repository for Firmware. Where I had my Drivers shared on a windows server I downloaded the Catalog.xml.gz from [URL] and added the repository through OMIVV. </s>
<s>[INST] Hi All I came across Static Host Name Mapping on powerconnect 3048 switch and wondered what it can be used for, is it like a hosts file on a server? Or does it have another use? If I have DNS do I really need this? Enlightenment please Thanks Eric [/INST] It is assigning an ip to a specific host, it really is only needed if the switch is acting as the dhcp server. </s>
<s>[INST] I have a disk in a raid 10 virtual disk that is failing. The physical disk caddy has an amber light on it and in the perc display it shows with an orange yield sign with an exclamation mark in it. I assume that means it is failing even though it is still running and not yet degrading the virtual disk. I have a new spare now to replace it. I don't have a spare slot in the chassis. If I did I would insert the new disk, make it a hot spare for the virtual disk, then pull the failing disk. Since I don't have a spare slot. what is the best way to approach this. In other words, do which series of commands in which order? Do I just take the failing disk off line, pull it, replace with new, mark it as hot spare? I'd kind of like assurance that I'm doing it in the right order before going ahead The disk is a member of Controller0, Virtual disk1. It is disk#6 on enclosure#32 And indeed queerying the disk gives me the same serial number as the one that shows in idrac with an amber exclamation mark [root[NAME]-VMware-Lam:/opt/lsi/perccli] ./perccli /c0/v1 show allCLI Version = 007.0529.0000.0000 Sep 18, 2018Operating system = VMkernel 6.7.0Controller = 0Status = SuccessDescription = None /c0/v1 :====== ----------------------------------------------------------------DG/VD TYPE State Access Consist Cache Cac sCC Size Name----------------------------------------------------------------1/1 RAID10 Optl RW Yes RWBD - OFF 1.635 TB SAS15K---------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=DegradedOptl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=ScheduledCheck Consistency PDs for VD 1 :============ ------------------------------------------------------------------------------EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type------------------------------------------------------------------------------32:10 10 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U -32:11 11 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U -32:6 6 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U -32:7 7 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U -32:8 8 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U -32:9 9 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U ------------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroupDHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global HotspareUBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-InterfaceMed-Media Type|SED-Self Encrypting Drive|PI-Protection InfoSeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-ForeignUGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shieldedCFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded VD1 Properties :==============Strip Size = 64 KBNumber of Blocks = 3512991744VD has Emulated PD = NoSpan Depth = N/ANumber of Drives Per Span = N/AWrite Cache(initial setting) = WriteBackDisk Cache Policy = Disk's DefaultEncryption = NoneData Protection = NoneActive Operations = NoneExposed to OS = YesCreation Date = 07-03-2016Creation Time = 01:18:54 PMEmulation type = defaultCachebypass Mode = Cachebypass DisableIs LD Ready for OS Requests = YesSCSI NAA Id = 61418770601b16001e703c3e0950c5f9SCSI Unmap = No [root[NAME]-VMware-Lam:/opt/lsi/perccli] ./perccli /c0/e32/s6 show allCLI Version = 007.0529.0000.0000 Sep 18, 2018Operating system = VMkernel 6.7.0Controller = 0Status = SuccessDescription = Show Drive Information Succeeded. Drive /c0/e32/s6 :================ ------------------------------------------------------------------------------EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type------------------------------------------------------------------------------32:6 6 Onln 1 558.375 GB SAS HDD N N 512B ST600MP0005 U ------------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroupDHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global HotspareUBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-InterfaceMed-Media Type|SED-Self Encrypting Drive|PI-Protection InfoSeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-ForeignUGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shieldedCFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded Drive /c0/e32/s6 - Detailed Information :======================================= Drive /c0/e32/s6 State :======================Shield Counter = 0Media Error Count = 0Other Error Count = 0Drive Temperature = 37C (98.60 F)Predictive Failure Count = 1S.M.A.R.T alert flagged by drive = Yes Drive /c0/e32/s6 Device attributes :==================================SN = S7M0QBXXManufacturer Id = SEAGATEModel Number = ST600MP0005NAND Vendor = NAWWN = 5000C5008F5CE770Firmware Revision = VT31Firmware Release Number = N/ARaw size = 558.911 GB [0x45dd2fb0 Sectors]Coerced size = 558.375 GB [0x45cc0000 Sectors]Non Coerced size = 558.411 GB [0x45cd2fb0 Sectors]Device Speed = 12.0Gb/sLink Speed = 12.0Gb/sWrite Cache = DisabledLogical Sector Size = 512BPhysical Sector Size = 512BConnector Name = 00 Drive /c0/e32/s6 Policies/Settings :==================================Drive position = DriveGroup:1Enclosure position = 1Connected Port Number = 0(path0)Sequence Number = 2Commissioned Spare = NoEmergency Spare = NoLast Predictive Failure Event Sequence Number = 6513Successful diagnostics completion on = N/ASED Capable = NoSED Enabled = NoSecured = NoCryptographic Erase Capable = NoLocked = NoNeeds EKM Attention = NoPI Eligible = NoCertified = YesWide Port Capable = No Port Information :================ -----------------------------------------Port Status Linkspeed SAS address-----------------------------------------0 Active 12.0Gb/s 0x5000c5008f5ce7711 Active 12.0Gb/s 0x0----------------------------------------- Inquiry Data =00 00 06 12 8b 01 10 02 53 45 41 47 41 54 45 2053 54 36 30 30 4d 50 30 30 30 35 20 20 20 20 2056 54 33 31 53 37 4d 30 51 42 58 58 00 00 00 0000 00 00 00 00 00 00 00 00 00 00 a2 0c 60 20 e004 60 04 c0 00 00 00 00 00 00 00 00 00 00 00 0000 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0000 43 6f 70 79 72 69 67 68 74 20 28 63 29 20 3230 31 35 20 53 65 61 67 61 74 65 20 41 6c 6c 20 [/INST] Billeuze, With the drive showing as an online Predicted Failure, you will need to force that drive offline (page 25 here). prior to removal. After that you should be able to remove the problem drive, wait about 20 seconds and insert the replacement. It should start the rebuild automatically, if not then you can assign it as a hotspare with commands found on page 34 here. Let me know how it goes. </s>
<s>[INST] Good day for all! I have MX7000 system with two MX740c blades.They all have latest firmware installed. OMM Version 1.10.10 (Build A00.726). I'm facing strange behavior when trying to create profile for sled. It has 2 mezzanine cards, one is QLogic 2x25GE QL41262HMKR CNA and another is QME2742 FC mezzanine. When I'm trying to create template using this sled as reference device and all parameters are checked, all NIC MACs and FC WWNs were captured as well. [IMAGE]Creating template with all parameters checked [IMAGE]FC parameters captured But I don't want to capture RAID configuration, so I unchecked this parameter when create another template. [IMAGE]RAID parameters are unchecked And then I got template without ANY FC parameters! [IMAGE]RAID = FC??!! Does it mean DELL equals words RAID and FC? Why? They are not the same! RAID option is for local disk configuration when FC is responsive for Fibre Channel Network communication as well NIC config is responsive for Ethernet Network communication. Moreover, it does have impact on deploying template. To check this I tried to deploy template with RAID config captured and it deploys well with both NIC and FC virtual identities assigned from pool: [IMAGE] What's the problem then, may you say. The problem is because of RAID configuration included it will re-create internal RAID array trashing all data on it. It is not desirable behavior when you want to just apply server profile to get old MAC-addresses and WWNs when migrating him to another slot when device stops working or needs maintenance. OK, trying to deploy template without RAID configuration - FC identities trashed out. [IMAGE] So the main question is why it is possible to capture only NIC configuration in template but not only FC? Any thoughts? [/INST] Well, Dell support replied that it's known problem in software and it will be fixed in a future releases. Have a nice day. </s>
<s>[INST] Hi all, We have already uploaded signed certificate from private CA.We are having our iDRAC scanned for security vulnerabilities by Qualys.Our iDRAC is on a network segregated from the production network by ACLs. We granted Qualys access to scan iDRAC in order to keep compliant with PCI-DSS and FIPS requirements.Qualys is reporting the certificate is not trusted. Our browsers trust our private CA, but PCI requirements won't allow Qualys to trust our private CA.Our only solution is to upload our CA bundle to the iDRAC. As per TLS spec, server certificates can include the CA bundle in the same file in the following format:server certificate, then intermediate CA, then root CA. So there would be 3 BEGIN CERTIFICATE lines and 3 END CERTIFICATE lines. I did successfully integrate the 3 certificates into one file in the above format. But the iDRAC indicates that the certificate is invalid and to check it in OpenSSL. I was able to verify the certificate in OpenSSL without issues. Please advise how we can upload all 3 certificates. [/INST] In iDRAC, Once you upload a certificate you can not upload the same certificate again. You are seeing the error message because of this. Can you try below steps </s>
<s>[INST] I know this is an old box, but it was running fine a month ago. I am attempting to use this for a home lab. I have tried minimum boot configuration, full configuration (as it was last running), and everything in between. The system begins to POST, but never goes further than about 20% of the progress bar. What I find interesting is that I can find nothing about a green LED on the PERC 6i card which blinks ~ on 1 second, off 1 second, etc. On the PCB next to this LED is white screenprinting reading "HEARTBEAT_ERROR" and I cannot find anything related to this. The boot process includes the full-rev on fans, which then settle down, the DVD has power, the populated 2.5" drives power up and doe the usual LED light show, then settle to solid green, and nothing further occurs. Removing any of the drives throws an error on the display screen, same for power supplies. It will not power up at all is the PERC riser card is not inserted, or if there is no memory. What else should I look into? Specifically interested in the green LED on the PERC card. [/INST] I think what I would want to do is get the server to the minimum to POST, power it up, and see what happens. You should be able to remove the PERC without issue, just not the riser it sits in. Min to post for this unit is as follows: ?System board ?Risers?Processor (CPU1) with Heatsink?Power Supply?One stick of memory in dual in-line memory module (DIMM) slot A1?Control Panel with cable Everything else (including the troublesome PERC) can get pulled. You might also look at flashing the iDRAC firmware from iDRAC Settings > Firmware Update, since the iDRAC would work with the BIOS. If it still won't POST, I'd be looking at the system board for replacement. As a point of clarification, when you said that it wouldn't start without the PERC riser, were you removing the PERC PCI card and it's riser? Or were you referring to the PERC as a riser itself? Don't want to recommend anything you'e already done, after all. </s>
<s>[INST] Hello, I bought a T320 recently, and the firmwares were very outdates (iDRAC, RAID, Network...) so I updated all firmwares and when I arrived into the iDRAC (2.63.60), I realized that the "Storage" menu displayed a "RAC0503" issue. So after searching on the internet, I was able to find solutions (link1) , but I haven't been able to correct that. After many tests (downgrading, resetting...), I was able to see a correct "Storage" menu with downgrading iDRAC to 2.30.30. If I upgrade to 2.40.40, the issue appends again. Here are the following firmwares: [IMAGE] Do I have to downgrade the PERC firmware ? Anyway, I'd like to upgrade to the more recent iDRAC firmware (2.63.60.62) without any "RAC0503" errors, even if everythings works fine (I can see and create RAID without problems with Ctrl-R menu), so it seems like a iDRAC issue. Thank you ! [/INST] Every time I've seen the issue, it affects the GUI *ONLY*. My next attempt would be to install the iSM, however, I don't know if you'll be able to install it in Proxmox or not. Are you running Proxmox bare metal, or in a VM? </s>
<s>[INST] Hi, so, we managed to have the OMIVV available in vCenter and we managed to add the Baremetal Servers. I created a Host Credential Profiles and verified that the Profile is working. ( there is already one host with esx i can test again) During the Deployment Wizard, onn the page "Select Host Credential Profiles: i choose "yes" so i get the option to choose the host credential profile for all hosts. Here the "Select Host Credential Profile" is gray and the dropdown does not show any Profiles Any idea whats the issue here? I also tried the "Deploy" from the Dashboard and the overview shows i have "0 Available" Host Credential Profiles. In the "Compliance & Deployment" Tab -> Host Credential Profiles i can see the profile i created and a test with an existing server works fine. Thanks for the support [/INST] Hi Simon Czechner, Is Active Directory user of ESXi host or IDRAC is used at Host Credentials Profiles ? If yes, Deployment wizard at OMIVV supports ESXi deployment with local user, not with Active Directory user .So, Host Credentials Profiles created with ESXi host or IDRAC Active Directory user is not listed at deployment wizard. If no, is linked vCenter registered with OMIVV ? Thank You,Vineeth </s>
<s>[INST] Hi good day, Please help to find out EOSL for below model list; Switch ? Dell Powerconnect 6224 SAN storage ? Dell EqualLogic PS6100XV [/INST] Hello VergilYong, With your PS6100xv end of support live is 7 years from date of purchase. For your PC6224 we would need your service tag. As a general rule with most Dell products the service life is 5 years from date of purchase. Please let us know if you have any other questions. </s>
<s>[INST] Hi community, I'm trying to use sudo to avoid granting admin and root password to operators team, they need to do some checks from SO side.Sudo allows us flexibility like this. avoperator[NAME]-04:~/#: sudo mccli client show0,23000,CLI command completed successfully. avoperator[NAME]-04:~/#: sudo mccli client deleteavoperator's password:Sorry, user avoperator is not allowed to execute '/usr/local/avamar/bin/mccli client delete' as root on ave-04. Now operator called "avoperator" has some new commands available after adding there lines in /etc/suders.# Extend permissions to avoperator group%avoperator ALL=(root) NOPASSWD: /usr/local/avamar/bin/mccli * show, /usr/local/avamar/bin/dpnctl status, /usr/local/avamar/bin/status.dpn There are no official avamar doc related to this config. Do you know if it is a config "blessed" by support? [/INST] seems that SUDO and privilege account management are unexplored lands in a Avamar¡¯s landscape. SUDO and privilege account management are forbidden lands in the Avamar landscape. Creation of additional OS-level user accounts on Avamar systems is not supported. Modification of the sudoers configuration on an Avamar system is not supported. You may be denied support if you make these sorts of changes to your system. If your operators specifically need mccli access to the system, I recommend installing the mccli package on a virtual machine as [NAME] mentioned above. The mccli guide for the most recent release is available here: [URL] A better alternative would be the Avamar REST API. The REST API underpins the new AUI interface. It is powerful, flexible, and freely available for customer use. Any tasks that can be performed using the AUI interface can be performed by calling the REST API directly. There is a getting started guide here: [URL] </s>
<s>[INST] All our instances of OMSA are displaying the same behaviour. We log in with the domain admin account, and it immediately logs us out. What I've tried: Re-installing OMSA Accessing locally/remotely Allowing connection to port 1311 (remote access was working 2-3 weeks ago) Checking the event viewer + log folders. I'm unable to see anything related to the connection. I've also tried with Chrome, FireFox and Edge to log in. Where can I go from here? I need to check the integrity of the drives regularly and without this tool - I'm in deep! [/INST] Hello Dave, Would you mind trying it once on OMSA 9.3 release? [URL] OMSA 8.5 is quite old and not sure what could have abruptly caused it over there. Please give it a try. Thanks Vivek #iwork4dell </s>
<s>[INST] I have a 2950 for which I created a USB DOS boot disk in order to upgrade the BIOS. I didn't see USB in the boot options, so I selected Virtual Floppy in the BIOS Boot Order, not knowing that option was for the DRAC interface management (?) When the system boots, it goes to RAID initialization, and after recognizing the drives, it sits there. The system is still responsive; num lock button still toggles off and on. If I select any of the F keys, it will show "Entering (Boot Menu, Setup,...), but it never enters those modes. Of course, it doesn't boot to the USB drive. How can I get into this machine's setup or circumvent the RAID initialization in order to get to the BIOS and change the boot order? I've saved the DOS files to a CD and attempted to boot from that, but same thing. The boot order is currently set as follows: 1. Virtual Floppy 2. CD 3. HDD Thanks if you can help. [/INST] wow, if it wont even go into bios, thats not good. I would try this:either:1. power off system, ssh/putty into the idrac ip and run: racadm racrest (this will reboot the idrac, you wont lose any settings) wait 5 mins, then power up the system. I would be surprised if this resolves it, but its a quick test. OR 2. power off the system, disconnect power, move the nvram_clr jumper on the motherboard (this clears the nvram), reconnect power cords, wait for idrac to spin up, about 4 mins, then power on the system. You should see this message during bootup "Caution! NVRAM_CLR jumper is installed on system board."After the system shows this message, you can power it off (if it starts booting to the OS, power it off)With the system powered off, move the jumper back to where it was, then power up the system again to see if it resolved the boot issue. Page 136 of the guide shows the location of the jumpers. [URL]#IworkforDell </s>
<s>[INST] I have a solaris client that needs to use pre-script & post script. Avamar has been setup to call the script which has been placed in:-/usr/local/avamar/etc/scripts Where can I add pre-script & post-script on client or avamar server ? Anyone has sample of pre-script & post-script , can you share it ? Thank you. [/INST] Hi, please keep in mind this default install path for solaris: /opt/AVMRclnt Script must be copied to /opt/AVMRclnt/etc/scripts folder (client side) You can use this sintax to create these scripts. #!/usr/bin/ksh # CommentFOLDER1=/opt/folder1export FOLDER1 </s>
<s>[INST] Hi, Just a quick question regarding NTP on iDRACs, are the iDRACs able to resolve FQDN named for time servers? Within the 3 NTP fields we tend to but in the FQDN then followed by IP numbers in the other 2 fields, however we'd prefer FQDN names if possible, I've checked the release notes but not seen any descriptions that explain this. Many thanks in advance. [/INST] Hello Yes, you can use FQDN. It doesn't look like it is mentioned in the manual or RACADM CLI guide. It is mentioned in the online help, click the question mark in the top right of the iDRAC web page to access online help. Thanks [IMAGE]iDRAC9 NTP </s>
<s>[INST] Hi all, I was checking out my configuration of Networker Server Client when I discover the Microsoft Exchange Server is missing on the Client Backup Configuration. When I testing to run configure new client for all of the DAG Client, None of the DAG member client have the Microsoft Exchange Server selection on the Available Application column. The backup is already running and there is no failure in backup and restoration testing during the time of discovery of this incident. The only changes so far was a reboot of the Exchange Server that cause the nsrexecd on the primary NMM client to be down ( another reboot to resolve it) and authentication issue ( resolved by delete the peer information between client and server ) [/INST] Renaming the nsrladb folder that is inside the res folder is never recommend. Bring back the old and delete the peer information again, this should help. </s>
<s>[INST] I just got a Dell N1124T-ON switch for my expanding home network. I chose this particular model because of its low power consumption (fanless) and the 4 SFP+ ports. The switch came with firmware v6.4.1.4 which I immediately updated to v6.6.0.10. Upon checking the features through the web interface I noticed Energy Efficient Ethernet (802.3az/EEE) is off for ports 21-28. I tried to enable it but the switch did not allow it. On the CLI I get following output when I list the green features: Port 21 to 28 show "Not supported"? Yet the user manual (June 2017 Rev A04) clearly states the following (page 642): All integrated 1G and module-based 10G copper ports on Dell EMC Networking N-Series switches are capable of utilizing the Energy Detect and EEE modes for reduced power consumption. Is this a bug in the firmware or an undocumented hardware limitation? [/INST] Hi, On that switch ports 5-20 support green ethernet. Page 70 [URL] </s>
<s>[INST] Hi guys, We have VNX5100 system connected to database system. Storage configuration, total disk 60. Disk type - 600GB 15K SAS only. My question, is there any impact if the host IOPS recorded via Performance Data Logging (.nar) exceeded IOPS from my calculation. For an example, from .nar , host IOPS max recorded is 12,000 but from my calculation, total host IOPS for my storage is 8,000. My calculation for storage IOPS is obtained from VNX Capacity Calculator. From .nar files, my response time average 15ms below. Latency average is below 10ms. But my concern is queue length across both SPs which average is over 10, max at 32. Does it effect my system since user complained about lagging and timeout? [/INST] sure - if you go above the performance capabilities of a config the the response time increases the IOPS info from Capactiy Calculator is just a very rough calculation - it doesnt take into account a lot of the details that are important </s>
<s>[INST] Hello All, I have following queries in Dell compellent Can someone help me here. 1) If a LUN is deleted from my Storage console [Storage Center], will the space will reflect in free space immediately or From VMware side we required to run any command to release the space ? 2) How to pull the Device ID for all LUNs in a report ?3) Will the snapshot occupy the space from their Respective LUN ? if so do we have any reserved space for it ?4) will there be any disrupt to LUN if we change their Tier on live?5) If a LUN is deleted in Storage console, can it be recovered ?6) Can i add a same server (Server1) to two different cluster ? will the server able to see the LUNs from both the Cluster ? [/INST] Hello Freddy99, Please let us know if you have any other questions. </s>
<s>[INST] Hi So we just bought a Dell R240 with a new Windows Server 2019 installed in it. This server have 4 HDDs 1TB each. Upon checking on the drives, it's only displaying Local Disk C (1TB). So my question now is, how can I see those other 3 drives? I'm planning to install Active Directory on this server.Any help is really much appreciated. Thanks, Carl [/INST] Hello There are a lot of possibilities. You should review the current configuration. The most likely scenario is that the drives are configured in a RAID 10. If that is not the RAID level that you want then you will probably need to delete and recreate the virtual disk. That would be data destructive, you would need to reinstall the OS. [URL] Thanks </s>
<s>[INST] I have an EqualLogic PS6100, which is out of warranty and we are unable to source replacement drives for. We have recently purchased a new EMC SCV3000, which will replaced the older unit. We are in the process of moving all VM's and data out of the PS6100, but this will take many months to accomplish. Our issue is that we have one drive, in slot #5, who's Disk Status is "Yellow" and reporting "Not Approved" and it's Health is reporting "Not Available." This disk is an original disk of the system, to my knowledge. In slot #22 we have a disk who's Disk Status is "Blue" and reporting "Spare" and it's Health is reporting "Healthy." It is my understanding that when the PS6100 sees a failed disk and has a spare on hand, it will automatically make the spare a RAID member. This does not appear to be the situation in our case. My first thought was to swap the drives, however I have also read of warnings about removing disks from the PS6100 and that it could lead to data failure. Does anyone have any experience with a failed drive who might be able to advise me on the correct path to take? Thanks in advance - Eric [/INST] Hello Eric, A "Not approved" message indicates that drive is NOT an EQL approved drive. You can remove it without impacting the RAIDset. It sounds like you are running RAID50? Since there should be two spares in that case. Sounds like the RAID status is healthy so there's no need to bring the other spare into the RAIDset. Regards, Don </s>
<s>[INST] I have a query regarding the VXRail initial setup. I have 3 x E560F servers, which comes with 4x10G SFP+ connectivity. During the initial setup, Is it possible for me to configure the VXRail with 2x10GSFP+ . And later on configure the unused 2x10G SFP+ dedicated for VM traffic? Any issues in the above configuration. Is this a good practice. [/INST] Apologies for the typo in the earlier. I was able to initialize successfully. During the initial setup, 2 NIC option was selected and disconnected NIC3 and NIC4. </s>
<s>[INST] Hi, a few weeks ago (less than a month) I installed 2x R710 server for internal purposes. Both have the same hardware configuration and running Windows 2019 LTSC. Each server is equipped with a H700 controller and a raid10 consiting of 4x 6TB (non Dell blessed) Seagate HDDs. All firmwares are the latest available. In the first week the servers running fine. One day I noticed a dramatically READ performance drop. The avarage read speed was arround 1MB/s while the write speed still reached the max performance. Strange, this phenomenom appeared nearly eaqually on both server. Because I've formatted the raid volume with ReFS my first thought was a bug with the filesystem. So I decided kill the raid and rebuilt it again, now with NTFS. Time goes by and this weekend the same issue appeared. Again nearly at the same time on both server. This time I investigated a little more and checked the file system, raid/hdd error messages an so on. But I did'nt found any indication. While a copy job was still running on one server, reading data from the volume, I decided to start a consitency chek on the raid volume (the first time!). At the moment I started the process the read speed jumps to (nearly) max again and the issue disappeared. I tested this on the 2nd server and again with exactily the same behaviour. Needless to say that the consistency checks both finished without any error. Any ideas? [/INST] I guess I've found the problem. The problem has something to do with Read Patrol and is reproducible on both servers. The read performance drops appearing while a Read Patrol task is running. The reason a constistency check solve the issue is that a consistency check cancels a running Read Patrol task. Although I don't know why this happen on this servers my solution is to disable the automatic Read Patrol and perform a consistency check twice a month. That is good enough for the purpose of these servers. </s>
<s>[INST] Hello, we intend to uplink S5248F-ON TOR to a Cisco C9272Q switch which supports only 40GE QSFP+ ports. What options do we have to downgrade the QSFP28 and connect it to QSFP+ Do these 4xQSFP28 ports support Dell QSFP+ transceivers or breakout 40GbE is needed? Let us know. Best regards, GP [/INST] Hi, Yes you can limit that to QSFP+ for 40Gb. Page 197 [URL] You can use QSFP+ transceivers and not need a breakout. </s>
<s>[INST] What's the model of motherboard of PowerEdge T620? Thanks [/INST] The motherboard in that server is the latest version (V6), part # G1CNH (or part # 67N22 for the motherboard svc kit) </s>
<s>[INST] i have noise fan on it i want no why [/INST] Leadaaa, Would you confirm what version firmware you have for the BIOS, iDrac, as well as the raid controller? I ask as it being out of date can cause the fans to max. Let me know where you are currently and I can let you know what is needed to update to current. </s>
<s>[INST] Dear Engineers I have two storage Unity 600 and We have launched a replication between these two storages.I want to unplug the destination storage device and connect it to some hosts separately and mount VMFS volumes for some reason. Anyways, I have stopped replication and even marked the destination LUN's as read/write again with this command in "Unisphere Cli", (uemcli /stor/prov/luns/lun -id set -replDest no ) But while I have completely disabled synchronization and also made LUNs Writable again, the virtual infrastructure does not recognize the allocated spaces as VMFS Datastore and recognizes them as new device and wants to format space for new datastore. do you guys have any idea about how i can stop the replication and use destination LUNs as VMFS datastore again ? thanks [/INST] Here is the Answer. you have to every Replicated or Disaster Recovered LUN has it own Signature so you have to mount the volume manually. so, Stop the replication between LUNs, no matter you do it from source or destination, just break the Replication. If you double click on the "REPLICATED LUN" on the destination storage, in the "REPLICATION Tab" you will find the warning about replicating or something. you have to remove the replication tag from the destination LUN, for doing that you have to use Unisphere CLI. (uemcli /stor/prov/luns/lun -id set -replDest no ) you can find the LUN ID using show (uemcli /stor/prov/luns/lun show) LUN is ready, if you get back to replication tab of destination LUN you will find the REPLICATION BUTTON and that's mean the LUN is ready to mount. SSH to one of the ESXi Hosts and use command blow to find the LUN you want to mount: esxcfg-volume ?l You can keep the LUN signature if you want just mount and check, but if you wanna use it in new environment its better to re signature it with -r command. So lets mount: esxcfg-volume ?M uuid/lable sorry for bad english/ </s>
<s>[INST] Hello, all. I've got 2 S60's running FTOS 8.3.3.8 as replacements to some 5248s. I had assumed that, from a default config that all ports would be in the same domain, but I can't get connectivity between a dell server on port 0 and the gateway connected on port 43... [Ubiquiti Pro8:eth1] (192.168.88.1/24) <--> [S60:port43] (192.168.88.231/24) [S60:port0] <--> Dell r710 (192.168.88.21/24) The Pro8's eth1 port has 192.168.88.1/24. I have assigned an IP to the S60's port 43 (192.168.88.231). I'm able to telnet to the switch from the Pro8, so the connection to port 43 is working. I cannot ping the r710 from either the gateway or the switch itself, and I can't ping out from the r710. When I move the r710's connection from the switch directly into eth1 on the Pro8, network connectivity works. Therefore, it looks like the switch is the culprit? I didn't factory reset the switch when I got it. There is a 10-net mgmt IP that is not used by us. Theoretically, all switch ports should be visible to all others unless they're segmented by VLANs, right? I'm not sure what in this config is missing or miscounfigured where ports 0 and 1 can't communicate to the Pro8. Any insight would be greatly appreciated! Also, there doesn't appear to be a way to factory default from the command line that I can see (I'm sure it's there somewhere). Switch config: FTOS#show runCurrent Configuration ...! Version 8.3.3.8! Last configuration change at Wed Dec 7 15:08:02 2011 by crsadmin! Startup-config last updated at Tue Dec 6 23:51:32 2011 by default!boot system stack-unit 0 primary system: A:boot system stack-unit 0 secondary system: A:boot system stack-unit 0 default system: B:!redundancy auto-synchronize full!hardware watchdog!hostname FTOS!enable secret 5 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx !!bsd-username crsadmin secret xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxusername crsadmin secret 5 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx!stack-unit 0 provision S60!interface GigabitEthernet 0/0no ip addressno shutdown!interface GigabitEthernet 0/1no ip addressno shutdown!interface GigabitEthernet 0/2no ip addressno shutdown!interface GigabitEthernet 0/3no ip addressno shutdown! [..same config on excluded ports..]!interface GigabitEthernet 0/42no ip addressno shutdown!interface GigabitEthernet 0/43ip address 192.168.88.231/24no shutdown! [..same config on excluded ports..]!interface TenGigabitEthernet 0/49no ip addressno shutdown!interface ManagementEthernet 0/0ip address 10.5.79.4/24no shutdown!interface ManagementEthernet 1/0no shutdown!interface ManagementEthernet 2/0no shutdown!interface ManagementEthernet 3/0no shutdown!interface ManagementEthernet 4/0no shutdown!interface ManagementEthernet 5/0no shutdown!interface ManagementEthernet 6/0no shutdown!interface ManagementEthernet 7/0no shutdown!interface ManagementEthernet 8/0no shutdown!interface ManagementEthernet 9/0no shutdown!interface ManagementEthernet 10/0no shutdown!interface ManagementEthernet 11/0no shutdown!interface Vlan 1!line console 0line vty 0line vty 1line vty 2line vty 3line vty 4line vty 5line vty 6line vty 7line vty 8line vty 9!http-server http!end [/INST] You can manage from any interface. Page 302 [URL] </s>
<s>[INST] Hi AllJust got my hands on a couple of new R540.Installed ESXi-6.7.0.Installed OMSA using the instructions <ADMIN NOTE: Broken link has been removed from this post by Dell> It is installed as I can see it in the package list.I get to the step "Accessing Dell OpenManage Server Administrator.", browse to the port 1311 the browser states. This site can¡¯t be reached Any clues as to why it is not working. (Yes I have rebooted) --David [/INST] HI All In short you cant do what I was expecting you to do.You have to have OMSA 9.3 running on a different server (and that has it's omen problems)Use the link at the bottom of the logon screen "Manage Remote Node" and fill in the details. </s>
<s>[INST] Hello i want to buy the dell power edge t140 and i want to create raid 1. onboard all servers have the s140 raid controler?and i can add a slot hardware controler whenever i want after that? [/INST] Andreaas Mettas, You can, the T140 supports adding an H330 or H730p hardware raid controller. Now in regards to the virtual disk, you can migrate it from one S140 to another, but you can't migrate the Virtual Disk to the H330/H730. You would need to backup the data, delete the virtual disk and then recreate it after installing the hardware controller. Hope this helps. </s>
<s>[INST] I have a rack of PowerEdge R810 servers. Each server has 4x Intel Xeon E7-4870 CPUs. The BIOS version is 2.11.0. I purchased 128GB of RAM (8GB DIMMs x 16) to add to the 64GB of RAM (4GB DIMMs x 16) already in each server. I put the 16GB DIMMs in A1-A4, B1-B4, C1-C4, and D1-D4, and the 4GB DIMMs in the remaining slots. This configuration is shown in the last row in the table in the manual on page 104. [IMAGE] All of the Hynix DIMMs that I purchased worked as expected with no errors. I received some Samsung M392B1K70CM0-CH9 DIMMs (8GB 2Rx4 PC3-10600R) that are giving me the following error during boot for each one of the 8GB Samsung DIMMs: "DIMM unsupported: DIMM xx. Lockstep Pair xx & xx disabled. Please replace the DIMM or remove the lockstep pair. Despite this error: If I remove the 16 4GB DIMMs, I get the same error, but the BIOS still recognizes the 128GB of RAM that is says is unsupported. So, my questions are: Thanks in advance to anyone that can help. David [/INST] I think you've done it all, any options to return the Samsung DIMMs?#Iwork4Dell </s>
<s>[INST] Hello, I'm a current user switching from HP management to Dell Management and I'm currently very unhappy with the result. While it's no unicorn and rainbow at HP, at least the tools work. Now, my current struggle is with DellBIOSProvider. At first, this tool is lacking any documentation (pretty much like most of dell tools). But beside that, there's no real installation or requirement. So while looking at the sample script (which, the one coding these seems to have basic knowledge of Powershell), I manage to create my own script that call DellBIOSProvider. Everything work on the OEM image. Yay. Let's do that in WinPE 10 now. Oh, nothing work, lots of error about missing smbios:. Let's ty the Load-DellBiosProvider cmdlet that's include with it. No error, great, I guess no message mean everythings good? Try again, no go, same errors. While looking on the internet, I finally found that it require either HAPI or OMCI. 2 Things that again, I fail to find any up to date information about it. HAPI, I find older Dell Command Configure information that send me to installation path of DCC in the x86_64 folder looking for HAPIinstall.bat file. Well, file doesn't exist and nothing short of near that. Ah yeah, it's DCC 4.2.1.568, you know, the one that doesn't work out of the box because it failed to installed required dependencies while not listing these on the website or the "installation instruction"? So, back to the root folder of DCC, there'S a installhapi.bat file. Launch that, file not found. Look at the script, it's trying to launch %0%\..\..\x86_64\hapiinstall.bat. Clearly, someone did copy paste, tried nothing. Ok, go back to x86_64 folder. Bunch of bat file for WinPE offline install, 3 dll and cctk.exe. Ok, let's try the offline install. Check the little doc, it want to create it from pe scratch. Install ADK, launch, errors.... Ok, I'll do it myself. Looking at the script, the only thing it does is copy the content of x86_64 to mount\command configure\x86_64 and add wmi in the startup script. This won't fix my issue. So, does anyone have a 2019 ways to get DellBIOSProvider to work so I can configure my bios password and bios configuration? Thank you [/INST] Well, I found out this link where it says VC++ 2010 and 2015 is required [URL] But then, it's talking about msvcr140.dll which is not in the redist anymore because of new naming and module merging by microsoft. This guy here tell us to put other files: [URL] I'm gonna try with that. Glad the only doc I could found on Dell Website, regarding latest version, isn'T up to date... </s>
<s>[INST] Hi, I'm looking at replacing the SSDs on our R730 (need to increase the size of the array), but wanting to know the status of the existing drives. Logging into the iDrac, the Remaining Rated Write Endurance for all of the drives is "unavailable". H730P Mini firmware at version 25.5.5.0005. Why is this and how can I fix it? Neil [/INST] Hello Write endurance reporting is a firmware communication issue. Make sure the firmware on the PERC and drives are up to date. If you are not using certified drives then they may not report correctly or at all. Thanks </s>
<s>[INST] Hello, We would like to know if it's possible to delete 'first level' quota from isilon. This quota not usage limits. Type AppliesTo Path Snap Hard Soft Adv Grace Files With Overhead W/O Overhead Over Enforced Container Linked----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------directory DEFAULT /ifs/data Yes - - - - 383200999 337.54T 273.15T - No No - How much impact does it have? It is possible improve performance? Many thanks. Regards. [/INST] good for trending capacity path usage. </s>
<s>[INST] Hello, I have a virtual disk (Raid 5, 3 physical disks) and I want to expand the virtual disk with another disk. The four disks are the same capacity and model. I found this article but I want to do it with iDRAC software. At the end of the article you can read: Add a disk in Virtual Disk without OpenManage Server Administrator Starting from the 14G generation server, it is also possible to add a disk using the PERC BIOS menu available at startup (F2). iDRAC 9 also offers this feature. My server is a PowerEdge R540 and iDRAC9 but, where can I find how to do it in iDRAC? Thank you [/INST] Hello I'm not sure if it is mentioned in the article, but the controller mode, RAID level, availability of unused space, and boot status may affect whether online capacity expansion/reconfigure tasks are available or will function. What I mean by boot status, if you are booted into system services or some hardware interface then some features within the iDRAC may not be available or may not be able to complete. You will need to exit system setup/system services and allow the system to boot normally for some features to be available. Thanks </s>
<s>[INST] We have a customer who has a Fire wall between DSITV Appliance and the vCenter Server, which IP Ports should be open between, DSITV, vCenter and DSM? [/INST] Hello LeonWilson, Here is a link to the Dell Storage Manager 2016 R3 Installation Guide if you look on page 12 you can see the ports that are used by DSM. [URL] Please let us know if you have any other questions. </s>
<s>[INST] I just updated to 3.3 and now my Firmware updates are failing. I'm not sure if its a bug or a configuration problem, but i get these two errors all the time now. [/INST] As part of multihoming support, OME 3.3 resolves FQDN name to IP address for downloading the catalog and updates from downloads.dell.com. The load balancer blocks the direct access to the servers using IP addresses outside of Dell networks. If you are not using a proxy and are using Dell online update method, you go through this path which results in failure to download the catalog and updates. If you are using Dell Repository Manager and importing the catalog/repository generated by Repository Manager can continue to use the same. You can open a support ticket if you encounter the issue. We are working on releasing a general availability patch at the earliest. Regards Abhijit #IWork4Dell </s>
<s>[INST] I've just bought (from ebay) a T320 with a non redundant 350w PSU and the PSU fan is very noisy as if it has no thermal control and is just set to max speed. This is not "it's failing" noise, it's just "it's running at high rpm" noise. The rest of the box looks fine and seems to work fine. The fan is certainly much louder than my T320s with dual 495w redundant PSUs when they are idling along ... and I think it's noticeably louder than when they are working at a normal level. The system board fan is fine... spins up when expected... drops down to a low speed/noise when expected ... so no problem there that I can see. Bios settings are performance per watt but don't seem to make a difference and I disabled C1E at one stage as I'd seen a comment about that somewhere. I've run it up through LCC and also to the installed OS and left it running for 30 minutes and no change at all. I've also run it up without disks (it has 4 x 1TB SATA disks installed on S110) The plan was to buy a box for non-critical low load test office work that would be nice and quiet, so maybe I've made a mistake. The person I bought it from said that the fan had always been that way. So the question is... what should I expect ... is it expected that the PSU fan will always run at full speed whatever the loading ... or should the PSU fan speed be related to load/temperature. TIA for your time and any comments Steve [/INST] Hi Steve, To answer your question, the PSU does not have any control of the fan speed on load or temperature. </s>
<s>[INST] I recently rebuit a T410 with dual 6-core XEON 32GB RAM and installed 4 "non-Dell" 1TB SSD. The system seems to run fine but events are constantly squawking about non certified DELL drives being installed. I went online and found DELL Certified drives and chatted with a DELL Support tech and ran the drive by him to see if it was compatible in my scenario... He replied yes and I purchased the drives but I dont believe he was correct as they are not showing in the PERC setup as available PD ... shows "0" PD. Here are the drives ... can anyone verify if they are compatible or not ? They appear to be SAS but thinking NOT .... 1TB SSD Intel DC P4500 SSDPE2KX010T7T Enterprise Data Center NVMe PCIe U.2 SFF-8639 2.5" DELL 0V51JV in DELL Bracket Intel¢ç SSD DC P4500 Series 1.0TB, 2.5in PCIe 3.1 x4, 3D1, TLC Any help or advice would be great ! Thanks JPNM66 [/INST] JPNM1966, I am not showing that drive as supported in the T410, it appears to be supported on the newer 14th generation servers. Also, the T410 doesn't support NVMe. Hope this helps clarify things, despite it being the answer you probably preferred not to get. </s>
<s>[INST] Have no clue were to post this. What I decided to do this morning was unsubscribe from the mailing list as I was getting sick of it and now I have been getting emails from dell every 10 minutes. I talked to tech support guy via chat about 5 hours ago saying he has me removed from the list... I'm still getting the emails. Please just make it stop. Here are the photos of the emails with time stamps [/INST] Closing this as solution as it seemed to stop on its own on November 10th around 12:20pm AST </s>
<s>[INST] Hi there, This is a legacy environment brought back online to recover ancient data. It is a Windows 2008 R2 VM running Networker 9.2. When attempting to recover any data I get a continuous string of: 6211 1573073988 2 0 0 8492 9072 0 dal-backup.tccilaw.com winworkr NSR warning 2 %s 1 0 90 162228:winworkr: Unable to read recover stream from server `dal-backup.tccilaw.com': busy.6211 1573073988 2 0 0 8492 9072 0 dal-backup.tccilaw.com winworkr NSR warning 2 %s 1 0 67 162229:winworkr: Required volume ausdd64001.001 status is 'mounted'6211 1573073988 2 0 0 8492 9072 0 dal-backup.tccilaw.com winworkr NSR warning 2 %s 1 0 52 162231:winworkr: Waiting 30 seconds before retrying. This happened on the 8.2 version as well, with slightly different text though. This specific data is sitting remotely on a DD160. Any guidance would be greatly appreciated. [/INST] This is resolved! We had to completely strip out all of the permissions on the data domain and added new permissions. Thanks for all the help! </s>
<s>[INST] Hello all, I am trying to configure raw device mapping for a local storage SSD on a Dell R720 with a PERC H310 Mini Embedded. This would be passed through to the ESXi hypervisor I have running on top of that. What I need to know is if the PERC controller passes the SSD serial and/or other SCSI VPD. I have been reading documents for the last couple days and cant find any information that confirms or denies this ability. Thanks [/INST] Hello I doubt it is fully supported, but I think it will work. The H310 and H710 should have similar functionality. I followed this KB article with an H710, and I was able to map a single drive RAID 0 and assign it to a virtual machine. Once I added it to the VM I went into disk management, onlined the drive, initialized, formatted, and assigned a drive letter. I then tested copying a 200MB file to the new drive, it worked. [URL] Thanks </s>
<s>[INST] I have a T320 with iDRAC Enterprise and a RAID-1 array on a PERC H310. I would like to replace one of the array's physical disks preemptively (not in failed state, or predictive failed state) and need to have the controller take it offline before I remove it. I cannot find in the iDRAC UI, or the iDRAC or racadm documentation how to do this. I would prefer to not need to use OMSA. Any way to do it? Thanks for any help. [/INST] I ended up updating the iDRAC firmware to get the new "forceoffline" command. Still in disbelief, with how much money I paid for this Gen-12 server, that I have to reboot to take a hot-swap drive offline in preparation for replacement! </s>
<s>[INST] Greetings, I'm hoping someone can assist us. Background: We have a Dell PowerVault 3400 with 6x 1.92 Tb SSD drives and two RAID Controller Modules. The RAID Controller Module Firmware is 08.25.14.60. It repeatedly will switch its status to "Storage Array Needs Attention". When clicking the link to see the details in the Recovery Guru, the summary states it is "Virtual Disk Not On Preferred Path". I followed this thread [URL] and followed the advice presented there: I've verified the controller firmware is up to date and updated the drive firmware. Issue: Below is the main issue I'm asking for assistance on... I can clear the error temporarily by going to Storage | Virtual Disk | Advanced | Redistribute Virtual Disks and the error will clear. The error will return within a couple hours. Here is an example from yesterday where I redistributed the disks (starting with event sequence number 3737 [NAME]:14:31 PM and it returning with sequence number 3749 [NAME]:06:33 PM) Below I have the Event Log Entries I think have details that may be helpful. What other information can I provide to paint a clear picture of the issue? Thanks in advance! Jeff Event Log Entries: Date/Time: 11/5/19 2:14:31 PMSequence number: 3737Event type: 210AEvent priority: InformationalDescription: Cache not enabledEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 0Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 2:14:31 PMSequence number: 3738Event type: 212CEvent priority: InformationalDescription: Virtual disk write-back caching restoredEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 0Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 2:14:31 PMSequence number: 3739Event type: 104Event priority: InformationalDescription: Needs attention condition resolvedEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 0Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 2:14:31 PMSequence number: 3740Event type: 502AEvent priority: InformationalDescription: Virtual disk ownership assignedEvent specific codes: 0/0/0Event category: CommandComponent type: Virtual DiskComponent location: Virtual Disk VD1Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 2:14:31 PMSequence number: 3742Event type: 210AEvent priority: InformationalDescription: Cache not enabledEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 1Logged by: RAID Controller Module in slot 1 Date/Time: 11/5/19 2:14:31 PMSequence number: 3743Event type: 212CEvent priority: InformationalDescription: Virtual disk write-back caching restoredEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 1Logged by: RAID Controller Module in slot 1 Date/Time: 11/5/19 4:06:32 PMSequence number: 3744Event type: 210AEvent priority: InformationalDescription: Cache not enabledEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 1Logged by: RAID Controller Module in slot 1 Date/Time: 11/5/19 4:06:32 PMSequence number: 3745Event type: 212CEvent priority: InformationalDescription: Virtual disk write-back caching restoredEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 1Logged by: RAID Controller Module in slot 1 Date/Time: 11/5/19 4:06:32 PMSequence number: 3746Event type: 210AEvent priority: InformationalDescription: Cache not enabledEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 0Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 4:06:33 PMSequence number: 3747Event type: 212CEvent priority: InformationalDescription: Virtual disk write-back caching restoredEvent specific codes: 0/0/0Event category: InternalComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 0Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 4:06:33 PMSequence number: 3748Event type: 2044Event priority: InformationalDescription: Virtual disk I/O shipping implicit transferEvent specific codes: 0/0/0Event category: InternalComponent type: Virtual DiskComponent location: Virtual Disk VD1Logged by: RAID Controller Module in slot 0 Date/Time: 11/5/19 4:11:32 PMSequence number: 3749Event type: 4011Event priority: WarningDescription: Virtual disk not on preferred path due to failoverEvent specific codes: 0/0/0Event category: ErrorComponent type: RAID Controller ModuleComponent location: Enclosure 0, Slot 1Logged by: RAID Controller Module in slot 1 [/INST] I'm happy to report that the issue is now resolved. The issue was that the SAS Interface card in one of the two connected VMWare host servers had failed. To identify which one, if you look at my server connection image it was slot 6 of "Server 1". [IMAGE] To summarize for anyone who is running into this issue in the future -1. check the cable connections - if those are ok... 2. swap cables around to see if you can identify a bad cable - if those are ok... 3. If you have a DRAC, login and check the storage interfaces. This is what identified the issue for me - in one of the servers (server 1), only 1 of the 2 storage interfaces was still showing, in our other server (server 2) both interfaces were showing. In hindsight, I should have done step 3 above first so I wouldn't have had to contact the remote hands team to check cables when it could have been seen if I just looked in the right place. Hope this helps anyone in the future - thanks again to the Dell team for your help in resolving this, we now have a GREEN status for this unit/system. Cheers! </s>
<s>[INST] Hi all, I'm looking forward to upgrade R910 servers. Currently it has 4 CPU (Xeon X7560) and each Processor RAM bank have 4 sticks of x 8GB DDR3 (SingleRank). Thus total 128GB of RAM. Current RAM population/config are like this [IMAGE] I would like to add on 4 stick of 32GB DDR3 (Quad rank) to double up the memory from 128GB to 256GB. Need Dell Expert to advise for the config. Thanks! [/INST] Yes, using only riser A(A,C,E,G)on each CPU is a supported configuration. </s>
<s>[INST] Hi, there is a fix to networker never endless running jobs state without use jobkill everytime. thanks in advance [IMAGE] [/INST] Now you stated the reason - so the time 'delay' is at least 4 hours. That's what I could not verify from your first statement/the screenshot. Let me suggest that you run nsrwatch and verify the workflow status from the command line. If it looks ok here, then the problem is obviously the GUI. in this case I would restart the NMC service. This will have no effect on NW still running in the background. Otherwise, it is hard to point to a specific issue without further information. In this case, I would suggest an update and/or contact DellEMC support. </s>
<s>[INST] I have a T320 with iDRAC Enterprise, PERC H310 and a RAID-1 array. I go to Virtual Disks, and add a Consistency Check to the array's Pending Operations queue. Then I go to Pending Operations to try to force the start of the operation, and it appears that I have to reboot to invoke the operation? I cannot believe that. Do I have to do this from the command line with racadm or (?) to invoke an immediate consistency check? Thanks for any help. [/INST] Hi John, Glad you have made progress on this observation. After initiating consistency check on H310 controller, make sure system is booted to host OS. After booting to host OS only, all the background operations start running by utilizing host memory in case of H310 controller. If controller (H310) is not booted to host OS, no background operation can be progressed from Pre boot environment. </s>
<s>[INST] l have an old Dell T310 Poweredge. I would like verify my server has the latest updates of firmware, drivers, etc., and was wondering if it OK to use Dell Command Update to check for the latest updates? [/INST] Dell Command Update is not an Enterprise software tool and doesn't support the server platform. My expectation is that if you try to use Command Update, it will not work, because the associated repositories would not be accessible. I would install OpenManage Server Administrator and check your firmware manually. The things to look at would be the BIOS, iDRAC, Lifecycle Controller, RAID controller, and NIC. You can compare them against the versions on the support site for the T310. </s>
<s>[INST] I have a question about implementing cloud tier on the IDPA The IDPA comes with a 5TB Cloud Tier license and I¡¯m trying to set it up using AWS as the target. In order to enable cloud tier on the IDPA though you have to assign disk space on the DDVE for the cloud tier cache. The IDPA documentation only covers basic installation and operation and refers to the Avamar and Data Domain documentation for anything else. However, when it comes to adding disk space to the DDVE, it is not the same, since the DDVE on the IDPA is configured as a vApp and warns you not to alter it directly. My question is, what is the correct procedure for adding disk space to the cloud tier cache on the IDPA? [/INST] It turns out you don't need to manually add storage to the cloud tier cache. When you configure cloud tier on the DDVE, it automagically adds storage to the cache. Hopefully, this will save someone else spending hours trying to find the undocumented answer. </s>
<s>[INST] This was added to iDrac 9 in one of the more recent firmware updates and broke our alerting. All of the alerting settings are still configured as they should but this new global alert on/off setting has been added and looking through: racadm eventfilters I can't find a racadm command to turn this global setting on. Anyone know what this would be? I did have a good dig around. I've attached a screenshot of the setting in the iDrac.[IMAGE] [/INST] Hi, racadm command to toggle the alert global settings in idrac9 This command will enable the alert racadm set iDRAC.IPMiLAN.AlertEnable Enabled[Key=iDRAC.Embedded.1#IPMILan.1]Object value modified successfully command to disable the alert racadm set iDRAC.IPMiLAN.AlertEnable Disabled[Key=iDRAC.Embedded.1#IPMILan.1]Object value modified successfully This settings will reflect in GUI according to CLI command. This is the command reference, let me know if you have any other query on the same. Thanks DELL- Sirisha U #Iwork4Dell </s>
<s>[INST] Hi I m using first time Islion storage (One FS). Having some issue that we are using windows systems as well as centos-7.4. Two map points are created M & F. We use domain server 2008rs and created a group support and all users are in support group. I want to map M & F by each user login which I could not. I dont have any problem in windows client systems. Find the below issue : 1) If I mount via root with filesystem nfs : the users are not modified any file write, but same task they can do in windows systems. 2) If i mount with filesystems cifs : the normal user cannot mount, until created .smbcredentials (where a test user and his password was given) in /usr/local path. 3) after cifs mount : all the files and folders in M & F mount points are shown owner and group is root. Here they can create any file but cannot modified after given modified permission. I need some guide in the above issue . Thanks in advance [/INST] A good overview of multiprotocol (NFS & SMB) file sharing with Isilon is: [URL] This blog series includes many links to more in-depth papers, and it also mentions RFC2307 which is usually the way to go and therefore deserves an extra document: OneFS: How to configure OneFS and Active Directory for RFC2307 compliance hth Peter </s>
<s>[INST] Hello!I have an EMC CX4-120 with an array for 15 FC drives. Only 10 disks of 450GB are installed.Can I install 5 SATA disks of 2TB each (EMC CX-SA07-020) in 5 vacant places?How to connect SATA disks to an FC connector? Thanks in advance! PS: Sorry for my English! [/INST] Hello Kudesnikkk, It depends on which DAE that you have with your CX4-120. Here is a link that explains about the different DAE¡¯s [URL] Please let us know if you have any other questions. </s>
<s>[INST] I haven't used the T330 before, and am considering buying one. My question is this: If I buy a T330 without a Raid controller, if I install my own SATA PCIe controller, and find four drive caddys, is there any reason I wouldn't be able to use a total of eight drives? I would like use a dumb non Raid LSI HBA SAS/SATA PCIe card to control all eight drives, or maybe four from the motherboard and four from the PCIe controller. (This is the recommended approach for FreeNAS, they suggest to avoid Raid controllers) If I find the four caddys would there be anything else I am missing? It seems there is only one model of T330 where the SATA backplane always has all eight Sata connectors, and I won't need to chase down a 4x drive cage, or another 4x SATA backplane. If I understand correctly, and everything is there, except for the SATA controller, this is a big advantage over HP, where I would have to find drive cages and maybe stub cables. Thanks for any help. Just want to confirm, [/INST] Hello I would not purchase the system with the expectation that you will be able to use an unsupported storage controller with the backplane. You will likely encounter issues attempting to use an unsupported controller attached to the backplane. The T330 only has one backplane option, it comes with an x8 3.5" backplane. It doesn't matter what configuration you order, you will have the same 8 slot backplane. The slots available will be determined by the storage controller that you are using. If you order the system set up to use the embedded storage controller(S130, I think) it will only support a maximum of 4 drives, slots 0-3. Slots 4-7 will be covered up by a plastic blanking panel. That panel can be easily removed to provide access to the remaining slots. If you want to use all 8 slots you will need to use something other than the embedded SATA controller as your storage controller. Upgrading from the embedded SATA controller to a hardware storage controller is not supported. We don't have kits or a process for the upgrade. You may not be able to purchase the parts necessary from us. Swapping between hardware controllers only requires the controller to be swapped, all of the cabling is the same between the supported hardware storage controllers. To upgrade from the S130 to an H330/H730 you will need the PERC, new SAS cables, and maybe an LED cable. Also, the system does not come with extra drive carriers. We sell carriers with drives in a kit, we don't sell carriers by themselves. If you order the system with 1 drive you will get 1 carrier and the rest of the slots will have blanks. Thanks </s>
<s>[INST] Hi, We have two cabinets in a data center populated with servers. One cabinet has our SAN and 2 DS-300B switches and servers connected to the fiber network. We would like to connect the 8 servers that are in the other cabinet. I think we have two choices: * Run 16 fiber xconnect cables between the cabinets from the servers to each switch or * Get two more switches for the other cabinet and trunk the switches What is preferred? Most of the traffic would be coming from the cabinet without the SAN, either over the xconnects or over the trunk. [/INST] Hi, It all depends what you want with your environment.If the existing switches in cab 1 have enough space (as in enough ports, and activated) to cater for the servers in the cabinet 2, then why not just have them over 16 fibers?If there is not enough space, then you need to get 2 new switches for cabinet 2, and ISL them together with minimum 2 fibers each. That would be the simple solution, if you want to cater for the future growth etc then I suggest to get in contact with your local DELL EMC rep. And check if a SAN refresh is something you need. Regards, Ed Schulte </s>
<s>[INST] Hi all, During boot up of a PowerEdge T620 (this is a used server that I am repurposing), I see a message: "TPM failure." In Windows, when I go to tpm.msc, it tells me that there is no TPM found. In the BIOS, I tried a few different settings with the TPM options but it makes no difference. The BIOS does, though, tell me that the TPM is active ?? The prior Windows Server installation on this server didn't use the TPM so I have no idea if the TPM was ever working or if there even in fact is a TPM module in this server that has failed (how would I know if there is one anyway ¡¦ did all T620's come with a TPM ?). This server is beyond warranty, and I don't think there's anyway to get a TPM replacement, other than replacing the entire motherboard ¡¦. so I may just go with Bitlocker with the USB drive option on startup.... [IMAGE] [/INST] I apologize, that was based on a different system type altogether. I suggest clearing the NVram and see if the TPM failure message clears out, if not then it will likely require a new motherboard to resolve the error. The jumpers for clearing the NVram can be found next to the coin battery on the motherboard. Poswer down the server and move jumper over, power the server to clear the nvram, power down afterwards and restore jumper to original location. After that then power up and let me know what you see. </s>
<s>[INST] We've recently started backing up DFS volumes with NetWorker (vers 19.1.1.1). We've have some failures with regard to not being able to read certain directories, the backup completes successfully apart from failing on a corrupt folder. We are investigating the corrupt folder but need to get past this issue for the time being. I know there are directives to skip certain files/folders and we are testing with those but is there a directive to specifically skip any files or folders that cannot be read? Thanks,Carl [/INST] No - such directive/asm does not exist. You may either leave the save set list alias 'all' and use an exclude/skip directive. However, I don't know what will happen when the filesystem 'walker' will encounter a directory with a defective name. Another method would be to setup a save set list which does not include the filesystem/directory in question. IMHO the best way would be to repair the filesystem - you have to do it anyway. </s>
<s>[INST] I have been tasked with composing a briefing regarding the EMC storage lines of products; the most important ones are those for data backup. What are the main differences between the IDPA and the DD line? Also, what OS does IDPA run? I can't seemingly find that info anywhere. Thanks for the help, guys. [/INST] FWIW, the iDPA configurations that I have worked on all included a Data Domain as a "lower assembly". So relative to that, the iDPA would provide all of its respective features, including the Data Domain associated ones, whereas of course, the Data Domain alone would only provide its own features. </s>
<s>[INST] Hello, I have a T110 II with a PERC H200 and 4 drives attached. It is working well. I want to add more drives. I have attached a second cable (P/N 042N7H, same PN as first cable) to the second connector of H200.System does not recognize when a HDD is attached to the second cable. Is there something to do to enable second connector on H200, or any limitation in server or controller ?Thank you, Frederic [/INST] Problem fixed, I had forgotten to connect power supply to the end of the 2nd cable. </s>
<s>[INST] I'm looking for a server that can take one scalable CPU (for now) and has support for NVMe drive bays. I checked R640 and R740xd but online configuration says that you need two CPUs to have NVMe support. Are all the NVMe drives really just connected to CPU2 on the motherboard? Or is this a sales thing and not a technical limitation? [/INST] Just an update for future reference. We solved our problem by going with Dell's AMD models instead. AMD CPUs have more PCIe lanes so they can support more NVMe drives and I/O in general on just one CPU. The R6515 and the R7515 are the ones we looked at. The R6515 would be the equivalent of the R640 and the R7515 the equivalent of R740xd. We went with R6515 model (1U) in the end as it had two extra PCIe slots as well as up to 10 NVMe/SAS/SATA drives using just the single CPU. The largest CPU that fits in this small server has 64 cores. </s>
<s>[INST] Hi Right now we have cluster of esxi 5.5. We plan to upgrade all to 6.7 soon. Same hardware (servers). What would be the best approach of settings in DSM? Should i create a new cluster, or can i leave the current one and just change the current type from 5.5 to 6.7 ? [/INST] Hello chenchen, You can leave the current cluster and just change the current type from 5.5 to 6.7. Please let us know if you have any other questions. </s>
<s>[INST] I have T330 w/PERC H330 controller configured as a RAID 1 with a dedicated hot spare. One of the array member drives failed so the spare automatically became a member of the array. In my experience if I simply hot swap the failed drive it will trigger another rebuild of the array making the replacement drive a member.If I power down the system then switch out the failed drive will current array members remain as they are allowing me to designate the replacement drive as the hot spare thus avoiding another rebuild.Thanks. [/INST] Hello In that scenario a rebuild should only occur automatically if you have a feature like copyback enabled. Copyback will copy the hot spare data to a replacement drive automatically and then set the hot spare back as a hot spare instead of a virtual disk member. I would not shutdown to replace drives unless I had to because the drives were cabled/not hot swap. It is best to do changes while the controller is online so that it can track changes. [URL] Thanks </s>
<s>[INST] We purchased a PowerEdge T110 II without an OS several years back. The warranty has expired. We never used the server very much. I would like to reporpose the server and use it for a workstation. I would like to replace the current hard drives with one or two solid state drives. Is this possible? If so which SSD's would best match with the server? What cabling would be needed? Would i have to reconfigure the Perc controller? Thanks, Terry [/INST] Hello It would depend on the storage controller that you are using. SSDs should work, but you may be limited to SATA SSDs with some storage controllers. SAS storage controllers support SATA as well. You should not need to change cabling. [URL] Thanks </s>
<s>[INST] I'm looking for a part number or link to purchase the rack mount kit for a T330 tower server. Accordning to this: [URL] "Your system can be converted from tower mode to rack mode. So I'm looking for all three of those in one kit. Thanks. [/INST] 321-BBTV I don't show it listed for online sale. </s>
<s>[INST] Hi, I've got an interesting one here, I'm running OME v3.2.1 and have an FX2 chassis that I'm trying to put a profile on. OME applies the profile fine however seems to fail when writing back the validation giving the below.. 'MsgID: CMC0015 PrintProfileCountError: Method IsProfileCountAllowed failed message(s): Specified share already has max (100) profiles.' I've flicked SMB from enabled/disabled and it files on both?? have checked my local host and there is no firewall enabled? its as if its failing writing back to the CIF share?? - anyone see this one? - thanks in advance [/INST] Not from memory, I would have to look it up on the OMEnt support page. All of the ports used by OMEnt should be listed in the documentation. [URL] </s>
<s>[INST] hello i have an R920 4CPU with a RAID1 hdd build-in configuration. 2 600 GB hdd. I wish building an RAID6 with 4 600 GB hdd. I installed 4 another hdd but the Perc raid utility don't find the new hdd. have you got an idea ? thank you [/INST] solved due to some racks troubles </s>
<s>[INST] Good morning, We are planning to add a PowerEdge R740 to our datacenter.Currently the configuration is composed of:2xPowerEdge R520 connected with a Dell PowerVault MD3200 dual controller SAN with 6Gb/s SAS cabling in redunded connection.Reading the PowerVault manual it seems possible to add other server connections.Currently there is plenty of space on the PowerVault and we don't need fast disk access. As now it is not affordable to upgrade the SAN too I hope it is possible in some way to connect the R740 too to the SAN.The default configuration on the dell site doesn't seem to permit adding a 6Gb/s HBA SAS card. Can the 12Gb/s card be used too with 6Gb/s connections or the connectors/protocol are different? If not possible is there a 6Gb/s HBA card that can be installed on the R740 that is compatible with the powervault? Thank You Matteo [/INST] Hello Matteo, You can use a 12gb sas hba to connect to your MD3200. You will need to get a 12gb to 6gb sas cable so you can connect your host to your MD3200. Here is the Dell part#1502C which is 12gb on one end and 6GB connector on the other. Here is the link to the Administrator guide & if you look on page 55 it explains how to configure host access. [URL] Please let us know if you have any other questions. </s>
<s>[INST] Hello, We are currently running Networker server with Windows 2008R2 on physical server. Since Windows 2008 is almost end of support, we need to upgrade our OS to Windows 2012 or 2016. We currently do not have budget to buy a new hardware with new OS. We have few options we would like to consider including virtualize our backup server. Once it is running on VM, we have the capability to use snapshot for rollback in case anything happened during OS in-place upgrade. What do you guys think on running backup server on VM? Maybe anyone have any idea how to proceed with this OS upgrade? [/INST] We also run the NW server in an virtual environment and just migrated 1. From physical to virtual 'mode' 2. From Windows 2008R2 to Windows 2016 You just need to keep in mind that you cannot easily recover the backup server himself if the virtual environment has been broken. The other issue is that you need to be careful when using FC hardware from a virtual environment - this could become tricky. </s>
<s>[INST] Hi. I'm trying to obtain mem usage via SNMP from a Dell Z9100-ON with 9.14(0.1). The OID for chStackUnitFlashUsageUtil I found in guides (1.3.6.1.4.1.6027.3.19.1.2.8.1.6 and 1.3.6.1.4.1.6027.3.10.1.2.9.1.6) are not working for me. Could you please tell me the correct OID for this model/version? Thanks is advance. [/INST] I found the corrrect MIB for Dell OS version 9.14+ DELL-NETWORKING-CHASSIS-MIB The OIDs of the table to obtain cpu an mem usage is: dellNetCpuUtilTable Extracted from here: [URL] </s>
<s>[INST] We have several S4148 switches with OS version 10.5.0.0. The problem is that the switches are sending a constant stream of IPv6 neighbor solicitations querying the other nodes connected to the network, without any obvious reason. Sometimes it is one or a few requests / second, sometimes a burst of 30-100 messages. I don¡¯t see any other switches (including OS9) doing the same. The network is IPv6 enabled, i.e. there is a router advertising the prefix and clients and servers using it. However, there is no IPv6 configuration on the switches other than the default configuration (¡°show running-config | grep ipv6¡± shows nothing). According to ¡°show ipv6 interface brief¡± all VLANs have the same link local address enabled but no global addresses. The switches have IPv4 addresses for management but no other L3 functionality. ¡°show ipv6 neighbors¡± shows a rather long list of addresses. Is there a reason why the switches are so interested about their neighbors with the default configuration? [/INST] Thanks for support! For the record, the issue vanished some time after I asked the question and hasn't reappeared. I guess it was a hick-up caused by some earlier configuration change and it might be difficult to reproduce it. </s>
<s>[INST] We have an existing RAID 1 group of two 512e 300GB 10K SAS drives controlled by a H730. Current plan is to add six 10TB NLSAS drives and create a RAID5 with one HS. I wonder whether it would be a terrible idea to purchase 4kn drives for their marginal efficiency increase and potentially run into problems since existing drives (although in different RAID) are 512e. Any input is highly appreciated. [/INST] 5X5CX62, The server and controller will both support using 512e and 4k drives, now with that being said you can mix 512 and 512e drives in the same virtual disk, but mixing 512 and 4k drives in a virtual disk is not allowed. So with you creating a separate Virtual Disk for the 4k, you will be fine. Hope this helps. </s>
<s>[INST] Hi guys! I am new to the forum, but I hope someone will be able to help install Cent OS 7 on it. I have the disk and the USB OS. The thing is I am told that I have to update the server firmware before installing a new operating system. I visited this page: [URL] to get the proper firmware for the r410, it is not listed. Can anyone help me, please? Thanks in advance [/INST] Joscarlio, There are several different ways to update the server (seen here). The Platform Specific method you had discussed is for 12th generation servers and newer, and the R410 is 11th generation. You can use the Server Update Utility (SUU)with the Lifecycle Controller (F10 on startup), or if there is an OS already installed (Windows or Linux), you can update from within that OS. SUU Linux SUU Windows Let me know if this helps answer your question </s>
<s>[INST] Hello I'm planning to get the PowerEdge T640 soon and I have a few questions regarding it. I will be getting the 18x3.5 inch drives rackmount version with a single 750W psu and a single CPU. 1- is there a drive size limit, and will there be a problem when using it with non dell drives ? I'm planning to use it with seagate 14-18TB drives...ironwolf pro maybe. 2- how are the drives connected to the motherboard with this configuration ? I don't need a raid card like the PERC H330, rather an internal HBA card, so does it come with an internal HBA card with the 18 drives configuration ? 3- in the chassis configuration, some configurations says "GPU capable", but the 18x3.5 inch drives configuration doesn't say that, what exactly does that mean ? I need one or two graphics cards on this system and maybe a few pcie cards, so does that configuration prevent me from doing so ? 4- how is the noise with such configuration, will it be quiet since it's a single cpu/psu configuration ? [/INST] Hello, The highest capacity validated drives were 14TB, but I wouldn't expect a higher capacity than that to cause issues. However, using non-validated drives may or may not work out. I would make sure to get them from a source with a good return policy, if you still want to try. You'll need an add-in HBA, the HBA330 should suit your needs, though you may want to read up on it some. I'll link to the manual, so you can get any specific details you may want. [URL] The server would need a GPU enablement kit, in order to provide support for a GPU card. The card is mostly there for power distribution purposes. As for noise, my expectation is that it would be loud. Its a server and you're wanting to have 18 drives installed, which are going to generate a fair amount of heat. Do you mind if I ask what you need the server to do? </s>
<s>[INST] Hello, We have a PowerEdge R630 server with 2 SATA disks on the PERC controller configured as RAID1. We updated the OS (windows server 2012 R2) of our server yesterday and rebooted the server. After rebooting, the second disk (drive 1) became faulty and the system doesn't boot (we tried also removing and reinserting that disk : same issue). We tried to boot this time with only the first disk plugged (drive 0). the system doesn't boot. On the iDRAC, it shows the state of that disk : foreign (although no operations were done on this disk). So the new situation is : 1 disk not faulty and shown as foreign and the other disk is faulty (and has been now removed). Can we fix the disk (drive 0) so we can recover the data inside? [/INST] User1962, The foreign flag is when the Virtual Disk data stored on the drives doesn't match the Virtual Disk configuration data on the controller. If you follow this link, on page 73 and 74 are descriptions and steps on resolving the foreign. </s>
<s>[INST] Hi everybody, I use NW 18. I can get VM backups via their tags from vCenter to DataDomain. I also want to take a clone backup of some of the VMs whose backups have already been taken. To make it clear and sum up, VM1 has backup and clone tags. VM2 has only backup tag. When I say get backup which VMs has backup tag, it takes both VMs' backup to Datadomain. I want to say get backup which VMs has clone tag to another Datadomain. Do you know how can I do that? Is there anybody who has tried and succeed? Thanks in advance. [/INST] Thanks everybody who responsed and sorry for late reply. I tried adding new policies and configure them as they have backup and clone actions. It worked. To explain it with an example I have 10 VMs and I want to take backups of all to first Data Domain 1, take clone last 5VMs to Data Domain 2. For the first 5 VMs I created policy_1 which has only backup action, for last 5 VMs I created policy_2 which has backup and clone actions. I configured policy_1's rule to get vms which have backup tags and policy_2's rule to get vms which have clone tags. At the end I could take backups of all to the DD1 and take clones of last 5 to DD2. PS: It was preconfigured DDs and Networker Manager. There was already backup and replication settings. So I didn't configure anything else. </s>
<s>[INST] Running ESXI 5.5 u3 on a single Dell PE T430 with a Perc H730. My current RAID volumes are all SSD with 64k stripe sizes and RAID10. I¡¯m adding a new ESXI volume using 4 x 2Tb SATA in RAID10 and this will mainly be a storage volume for an existing Windows Server 2016 with Word, Excel and PDFs. What would the best stripe size to use for this new RAID volume when I setup in my iDRAC? I understand that smaller files benefit more with smaller stripe sizes like 64k. Thanks for any input. Ken [/INST] It's really going to come down to the load you put on the system. If you're storing lots of smaller files, a smaller stripe size may be beneficial. However, I'm not convinced that you'd notice much of a difference. I would somewhat expect the differences to be somewhat minor. I generally recommend to use the default settings. The presence of cache on the controller that accelerates reads and writes I would expect to mask most of the differences. You might see more of a benefit if you were trying to tune for a system with high-performance needs, but in this situation, I would think the defaults would work out well. </s>
<s>[INST] I have a PowerEdge T320 that I'm looking to upgrade at low cost. I have already increased RAM and looking at SSDs but my focus is now on CPU Upgrades. I have seen on a similar thread a compatibility table was published that lists a lot of E5-2400 V2 chips, but I have also seen on dell.com that it's compatible with the non-V2 E5-2400 series. What I have any eye on is an E5-2470 "v1" and I just wanted to check this is compatible before I go and pull the trigger and order it - the price difference from the V1 to V2 seems rather steep so would like to avoid a v2 if possible [/INST] The E5-2470 is compatible, according to the parts database I'm looking at. I'll share the related Intel ark page, just to confirm that you and I are on the same page. The part number I'm showing for this service kit is W1T58. [URL] </s>
<s>[INST] Right now, I have a copy of OneFS version 8.2.0.0, installed on vSphere on a 1.5TB ESXi drive. I have a single node, and want to perform some archive/restore tests with it. However, the 18.7 GB provided by default by the node is too little for my data set. How can I increase the space on the node? I've tried a few things: I've increased the size of the data drives in vSphere, and then used the "gpart resize" command to use that space on the Isilon node. The partitions of the six data drives on the node expand, but this is not shown in the OneFS GUI, and it's still showing 18.7GB. I've tried using "growfs", but that hasn't worked. Finally, I've tried re-adding the drive using "isi devices drive add", but that hasn't increase the space recognized. What can I do to get OneFS to see the additional space on the data drive partitions? Thank you. [/INST] If anybody else has this issue, I received a PM with the solution. The drives must be resized between deploying the OVF template and doing the initial command line configuration. Any drive resizes after the initial command line configuration will not propagate over to OneFS, even if you expand the partitions via the command line. </s>