text
stringlengths
29
274k
<s>[INST] Hello, I'm unable to connect VNX5300 via GUI (USM/SP) using sysadmin account while ssh to CS using root is fine. Apparently naviseccli can talk to spa/spb. As you can see below the spa/spb complains that security is not initalized. If I try to create a new administrator user (ie: sysadmin2) it says that credential on control station is invalid. Any help or suggestion to fix this is really appreciated! (also [URL]|spb]/setup reports "Domain Security Uninitialized - Please initialize the security using Unisphere or Naviseccli") Thank you, Andrea [nasadmin[NAME]-cs0 ~]$ naviseccli -h spa getagent Agent Rev: 7.32.33 (9.2)Name: K10Desc: Node: A-CKM00122601488Physical Node: K10Signature: 3244558Peer Signature: 3244576Revision: 05.32.000.5.249SCSI Id: 0Model: VNX5300Model Type: RackmountProm Rev: 7.20.00SP Memory: 8192Serial No: CKM00122601488SP Identifier: ACabinet: DPE8 [nasadmin[NAME]-cs0 ~]$ naviseccli -h spa security -listSecurity is not initialized. Add a global administrator to initialize security.[nasadmin[NAME]-cs0 ~]$ [nasadmin[NAME]-cs0 ~]$ naviseccli -h spa security -adduser -user sysadmin2 -password sysadmin2 -scope global -role administrator -type systemWARNING: You are about to add user: sysadmin2 Proceed?(y/n) yAdd user operation failed. The internal credential to the Control Station is invalid.Log in to the Control Station as root and run /nas/http/bin/set_passphrase IP_SP[nasadmin[NAME]-cs0 ~]$ [nasadmin[NAME]-cs0 ~]$ [nasadmin[NAME]-cs0 ~]$ suPassword: [root[NAME]-cs0 nasadmin]# [root[NAME]-cs0 nasadmin]# /nas/http/bin/set_passphrase 10.58.11.198/nas/sbin/classic_navicli -np -h 10.58.11.198 getagent 2>&1Error returned from AgentAgent denied request -- Caller not privileged. /nas/sbin/classic_navicli [-p] [-v|q] [-m] [-np] [-t timeout] [-h hostname][-d device] [-help] [-f filename] CMD Possible commands are: alpa arrayname arraycommpath bind baseuuidcachecard chglun chgrg clearlog clearstatscreaterg emconfiguration failovermodeflashleds firmware getagent getall getarrayuidgetatf getcache getconfiggetcontrol getcrus getdisk getlog getloop getlun getresume getrg getsniffer getsp getsptime initializearray inserttestevent luncachelunmapinfo managedby managefiles mirrorview ndunetworkadmin port r3wrbuff readcru readlunrebootSP register removerg reserved responsetestremoteconfig sancopy setcache SC_OFF setloopsetraid5 setsniffer setspstime setsptime setstatsshutdown snapview storagegroup systemtype spcollectspportspeed trespass unbind unitserialnumberupload setfeature Too few or invalid command line parameters Unable to set passphrase.[root[NAME]-cs0 nasadmin]# [/INST] Hello, in order to initialize security I had to connect to SPA via console cable. Here instructions to be followed: [1] cable needed: 038-003-084 EMC Null Modem Micro DB9 to DB9/F Serial Cable ? 25 Feet [2] Plug the serial cable into the service port on Storage Processor A. Set up a serial PPP VPN on a Windows laptop using 115200, 8, n, 1. Username is clariion, password is clariion! - Doesn't matter what you put for the phone number. [3] After the PPP dialup has been created in Networking close out of that wizard and navigate to: %appdata%\Microsoft\Network\Connections\PbkEdit the rasphone.pbx file in notepadChange Type=1 to Type=3Dial with login clariion/clariion! [4] point a web browser to 192.168.1.1/setup. Scroll down until you see a button that says Reset Domain Security. Click this and OK to the pop-ups. Note that this is **not** disruptive to array operations - you can do this anytime. Repeat for Storage Processor B. Now disconnect your serial cable, fire up your Unisphere session and you'll be prompted to create a new administrator user and password. Done! Thx, Andrea </s>
<s>[INST] I have 3 dell s4048T switch types I want to make an intervlan connection, I make 2 vlan on the top switch then I trunk to the 2 switches below. how to connect between different vlans so they can talk to each other on the top switch? I have vlan 40 and 41. Thansk [/INST] Page 55 of the guide covers copying config files off the switch. </s>
<s>[INST] I have three stacked 6248s, running version 3.3.18.1. The three are connected by stacking modules as well as interconnected by 10 gig CX4 modules. Something has changed and unit #2, interface X4 is now marked "Down" while all of the other interfaces are showing "Up". I've rebooted the stack and the connection remains down, possibly a bad CX4 module. With the module wires criss-crossed as expected will this ensure data continues to flow as expected? The main reason for this posting is that I am also seeing non-stop postings in the "Buffer Log" of: I have NO idea what 3/0/51 is telling me. It sure looks like unit 3 and port 51 but on a 6248 port 51 isn't exactly possible, unless it has to do with the CX4. Does anybody know what this error is pointing at? Any advise is greatly appreciated. Unit / Interface / Mode / Link Status / Speed 1 xg1 Stack Up 121 xg2 Stack Up 121 xg3 Ethernet Up 101 xg4 Ethernet Up 102 xg1 Stack Up 122 xg2 Stack Up 122 xg3 Ethernet Up 102 xg4 Ethernet Down Unknown3 xg1 Stack Up 123 xg2 Stack Up 123 xg3 Ethernet Up 103 xg4 Ethernet Up 10 [/INST] Solved: For future reference, figured out that it was in fact an XG port. Unit 3, the CX4 module XG3 error due to the Unit 2 CX4 module XG4 was down. </s>
<s>[INST] Hi I'm new to here Have a raid 5 virtual device offline, in VD Mgmt when I check properties of my virtual device. It show 4 physical disks and 2 missing disks. Then I switch to PD Mgmg page, it shows 4 online physical disks with state online (Driver 01, 03, 04, 05) and 1 with state foreign (driver 02). I checked my iDRAC and server found a record "Fault detected on Drive 0". I assume one of the two missing disk is Drive 0, but why my Drive 2 state changed to foreign? (Checked server, driver 0 led is off and other is on) Is there any solution to get my raid 5 back to online? (have a spare disk without installed) Thanks in advance Update: After import driver 2. I was able to boot the system and backup all hyper-v vm data [/INST] In your position, I would just go ahead and delete the RAID 5, swap both drives, lay down a new virtual disk, reinstall, and recover from a file level backup. It'll be a pain in the butt, but it will leave you covered from any replication of bad data blocks causing storage problems. However, if you export a RAID log and it looks like there aren't any errors on the foreign drive, importing and rebuilding will be fine. Provided that disk 0 was the only one with errors, you could very well be fine. But if there are errors on drive 2 as well, those will replicate on the first rebuild and swapping out that drive would migrate those bad blocks back when the rebuild starts. If there is any volume of bad blocks, then reading and writing all of them may lead to drive failures. The best way to proceed really depends on what you see in the PERC log. However, the safest option is the one I listed on top. </s>
<s>[INST] Hello, I am currently setting up this hardware, each half being located on the same site but in a separate building, roughly 350 meters apart from each others. My intend is to run manufacturing application running in virtual machines (Hyper-V) and provide high availability with automatic switchover in case of single-component failure. It is my first experience with this kind of hardware, things are currently setup as follows : Based on this design, could someone do some recommendations and/or corrections if I did anything wrong ? Best regards, Benoit. [/INST] Hello Ben0it, Here is the link to the Administrator guide for your SCv3020 & it explains more how to configure your replication on page 520. [URL] Please let us know if you have any other questions. </s>
<s>[INST] A subset of PowerConnect switches use VxWorks. I think they they tend to report VxWorks 6.5 or so, which falls in the range known to have the vulnerable "IPNET" tcp/ip stack. *Are there any early statements (or even speculation) about whether these PowerConnect switches using VxWorks are considered vulnerable to the URGENT/11 exploits? So far, I've been unable to find information to clarify this. Until an official announcement is available, would disabling all remote management (leaving only direct serial-port access) be a potential mitigation? I see a PowerConnect 62xx firmware update as recent as February 2019. Does this suggest that those models, if found vulnerable to URGENT/11, might receive a patch and/or mitigation statement soon? [/INST] Hi, We have not released any specific information on this exploit. In general if there is a security update needed older hardware will still get updated. </s>
<s>[INST] HelloSimple question, does anyone know the airflow direction of a 13th Gen Dell R230?- Is it front-to-back or back-to-front?I hope someone can help, thanks! Best RegardsFrederik [/INST] Hello It is front to back. The fans in the fan assembly near the center and the power supply fans will flow front to back. Thanks </s>
<s>[INST] I have a running R720xd with a 4 TB SAS HDD, Product ID WD4001FYYG that needs to be replaced in a RAID array. The service tag says the Part Number is 400-26601. This PN is no longer available and the closest one I can find is the 400-ALRT. Is the new part number hot-swap compatible with the existing disks? Thanks. [/INST] I'm showing the only difference between these drives to be a 6Gbps connection vs a 12Gbps connection. The new drive won't be able to reach the full connection speed, but will still work fine as a substitute for the original drive. I am confused though, with both of these being SAS drives, did you have a question about SATA, or was that just a typo? </s>
<s>[INST] (First post was marked as spam) We have a PowerVault MD3220i that we have been using for storage for several years. Due to issues with stability that have been encountered recently as its utilization has increased, we decided to upgrade the firmware. The original firmware version that was installed was 07.70.06.63. Per the upgrade instructions, we upgraded it to the bridge firmware version of 07.75.28.60. During the upgrade, the NVSRAM version was also changed. However, in the case of the NVSRAM it appears to have been a downgrade from N26X0-770890-005 to N26X0-784890-004. This occurred on the controller in slot 0 but not for the controller in slot 1. The controllers are now currently marked as Unupgradeable due to the following data validation error: Data validation error: The storage array cannot be upgraded as host port type representation in RAID Controller Module A did not match with those of RAID Controller Module B. This appears to be due to the NVSRAM version mismatch. Despite re-clearing the event log and rebooting the entire array (and leaving it powered off for 10 minutes), we have not been able to get the controllers to sync the NVSRAM version. Additionally, although we can connect to the controller using the serial port, during the controller boot process the output is either garbled or not displayed (the cursor blinks rapidly as though data is being received but not rendered). We are hoping to get some insight on how to get past being "stuck" on the bridge firmware/NVSRAM. Thank you for any help. [/INST] Hello txthenning, Have you tried swapping the slots that the controllers are in and running the firmware update a second time? I have seen this in the past that one controller will not get updated and by putting that controller in slot 1 and running the firmware again it resolves the issue. Did you happen to pull a support bundle before you tried to upgrade the firmware? Please let us know if you have any other questions. </s>
<s>[INST] Greetings everyone, my company has an old PowerConnect 2724 switch (L2) and several resources connected to it, on the same network. I want to isolate one or more resources (endpoints) in different VLANS (say 9 VLANs) and add a firewall (Pfsense appliance) between my ISP and my network, using it for internal / external purposes (blocking unspecific traffic ports, create VPN and so forth). The problem is that my switch is L2 and it cannot route the labeled VLAN packets. So, I¡¯m wondering to buy Dell X1026 (L3) and cascade it with my L2 switch, creating something like this: ISP >> router / gateway >> PfSense Appliance >> Layer 3 Sw (Routing) >> Layer 2 Sw (9 VLANs) >> Endpoints However, I have a few questions related to this topology in order to worth the investment on L3 switch: Best Regards Rafael [/INST] Hi, It should work, the 2724 can have ports with tagged VLANs that could be used with a trunk port. Though it might be better to remove the 2724 and just use all X series switches. </s>
<s>[INST] I have 2 Dell PowerEdge R640 servers both running VMware ESXi 6.0.0 5572656. One that is about 6 months old connects to my Equallogic PS4100 without issue, my new one is set up exactly the same but I receive the 7.4.3 login to target failed, reason: "Initiator is not authorized for this target" error. I have no access policies and no CHAP configuration. [/INST] Found an error in the EQL configuration. When I added the new server to the access control list for the volumes, I had an * for CHAP rather than the appropriate information. All is well once again. Thanks, </s>
<s>[INST] I've been asked to restore a T320 PowerEdge server infected with the Acute Ransom Virus. Almost all files (data and executable) have been encrypted. It appears that I will have to do a new Op/SYS install. No CD or USB available. I have MS Server 2008 R2 license info. I need the software. How can I get that? Other options? Let me know. Thank you in advance! [/INST] You can download the evaluation from Microsoft:[URL] In order to activate it with your key, you will need to first "convert" the install from evaluation to retail: DISM /Online /Set-Edition:ServerStandard /ProductKey:XXXXX-XXXXX-XXXXX-XXXXX-XXXXX /AcceptEULA (Takes 10-20 minutes, then reboot twice.) </s>
<s>[INST] So I have an old power edge 2850 its running and boots how ever I have 4 HDD's installed and it says "Remove disks or other media press any key to restart" on top of that when it was loading it got halfway saying "Loading files" but never went any further. Any advice on what to do from here? Im trying to get it to boot off of an external drive with windows server 2019. [/INST] Do you mean the OS would be INSTALLED TO an external drive and that would be your host OS? Yeah, THAT can't be done. If you mean you are trying to BOOT to a Windows INSTALLER on an external (USB) drive, then yes, that is possible on a 2850. We would need to know how you prepared the installer in this case to see what went wrong. The 2850 does not support Server 2019. In fact, many people have reported it will not take Server 2016 or even Server 2012 even - as in they can't even get it to install/run for a variety of issues, but I don't have one to test with. Runs 2008 R2 fantastically though. </s>
<s>[INST] Hi there,Trying to figure out a really odd issue. This particular network has been running fine for ages with no issues at all. All the switches are N3024's either in single, double or triple stacks. I have one switch in the network that has suddenly starting dropping off the network.There are three links into the switch, one fiber and two Microwave to ethernet and when the switch drops off I found that cycling the links at the other end would bring the switch back up. Further diagnostics show that if I leave one of the Microwave link ports disabled at the other end the switch stays perfectly stable. Enable that link and almost immediately the switch drops off the network.Nothing has changed with regards firmware (although they do need updating) but I can't see why all of a sudden this one switch has started playing up. I also swapped the switch out for another one just in case it was a hardware fault but I'm seeing exactly the same behavior on the switch I've put in which makes me think it's some sort of config issue. Any thoughts? [/INST] It does seem like it is something with port 22, what is it connecting to? </s>
<s>[INST] Hello, I recently purchased a Dell PowerEdge T340 and the HDD caddy that came with my HDD has the DP/N: 058CWC. To the best of my searching this DP/N corresponds to the 13th generation HDD caddy, and was just looking to verify that this was correct. I couldn't find a DP/N that corresponds to the 14th generation. Do I understand everything properly? Is the T340 compatible with the T330 HDD caddy? Reason being I'm looking to buy a few more, but Dell doesn't offer them as a standalone product, e.g. they only come with drives purchased from Dell, but I've found a Dell certified partner that does sell them. I'm aware of the other issues related to buying a non-dell certified drive, but this post is strictly asking about the DP/N and compatibility. Thanks in advance! [/INST] Jh2399, The carrier 58CWC is showing as compatible with the T340, and 90% of the systems that it shows as compatible with are 13th generation system, but the T340, T440, T640, and T740 all show the 58CWC drive carrier as compatible as well. Hope this helps. </s>
<s>[INST] I'm curious to see why there's two firmware versions on the download page for my N2048P, with versions marked as current/latest. Version: 6.5.4.4 ,A47 with Release Date: 28 Jun 2019 and Version: 6.6.0.2 ,A00 with Release Date: 03 Jun 2019 I assume one version is a Stable release and the other one is for Early/preview but I'm not sure which one is which. I'd prefer to stick to a Stable release. If it helps,the currently installed firmware version is 6.3.1.8. Does anyone know which version is the stable one? or Why there's two latest firmware versions? Thanks, [/INST] Hi, Both are stable releases, it is just the two most recent that we have on the page. </s>
<s>[INST] Hello Everyone, Every physical port will be assigned a virtual port when it comes to Virtual Port mode in Sc Series. Do we need to add the virtual port manually or does it get assigned automatically ? The virtual port is being added for port no 1 for both the Controllers but not for other ports in the Controller. I have connected all of them via the SAN switch as recommended . The virtual port mode is not being assigned in my case for Dell Sc7020. [IMAGE]Virtual Port Error [/INST] For every one physical port there should be one virtual port attached to it. If you have more than this it is due to the issue you had previously. You will need to contact support to have them delete the extra virtual ports. There is no other way to correct this. </s>
<s>[INST] Hello, We're in the processing of doing a OME rollout, and have joined one iDRAC to Active Directory for testing. I'm able to login to the iDRAC with Domain Credentials but cannot do the OME Discovery job with a Domain Account? I've tried defining the domain\user & user[NAME].com in credentials used for the discovery job but neither have worked? Is there something I'm missing? [/INST] So defining the entire FQDN/username is what's required. Yesterday, I did mydomain\username & username[NAME].com but neither of these worked. Today I used mydomain.com\username & it worked. Thanks for you help. </s>
<s>[INST] My question is simple... I've got a PERC H730p Raid card in my Dell R740 with 16 bays. I have 10 drives that are 800gb 12gb SAS SSD in a Raid array, and then 4 1.6tb 6gb in a Raid array. My question is will the 12gb array maintain it's true 12gb transfer rate if I have a separate 6gb array on the same card, or will it clock the 12gb one down? I know that if I were to mix the drives in a single array it will use the lower speed. This is not the case. These are separate arrays. Thanks! [/INST] Hello Drive transfer speeds can be mixed across the controller. You can mix transfer speeds like SAS 6Gb/s and SAS 12Gb/s in both a virtual disk and across the controller. You can also mix drive access speeds within a virtual disk or across the controller. If you have a virtual disk with five 12Gb/s 15000 RPM drives and one 6Gb/s 7200 RPM drive all drives will operate at their rated transfer speed and internal access speeds. Having that 6Gb/s 7200 RPM drive in that scenario will likely affect performance of the virtual disk. The other drives will still operate at 12Gb/s 15000 RPM, but the controller may have to wait on the slower drive to perform actions. The slower drive could create a bottleneck within the virtual disk. [URL] Thanks </s>
<s>[INST] I want to differentiate bewteen Isilon 8.x and 7.x using REST API calls. One Isilon 8.x, we have platform/3/cluster/version API which gives me isilon's version. Does similar API work on Isilon 7.x as well? [/INST] try this API command: [URL] Look for "release": These are the OneFS API versions and their corresponding releases: OneFS versionAPI version </s>
<s>[INST] I had purchased PowerEdge T30 server from amazon.in (Seller: Eagle Information Systems Pvt. Ltd.). Now I have some problem while booting system so I called India technical support (1800-425-9052 and 080-2510-7910) and when I enter my (Express Service Code:) it says this isn't valid Express Service Code. But When I add product in my Dell account it showing same Express Service Code. Please help how to get correct Express Service Code so that I can contact dell India technical support. Here is tag and Express Service Code: Service Tag Express Service Code: [/INST] Saurabh_d, I see that you now have a case open regarding the issue, the case owner looks to have reached out to you via phone and email. Touch base with them and they will be able to assist in getting you resolved. Also, from what I see the svc tag and exp svc code you provided are accurate. </s>
<s>[INST] We have an XR2 with DellEMC-ESXi 6.7U2 installed. PERC H730p My question is... On this customize image, are there ant Dell tools to monitor the server?For example to control or monitor, PERC, RAID?If yes, is there a link where I can download the manual? Thanks. [/INST] Not by default, though tools are available. The Dell custom image just includes drivers. For hardware monitoring, OpenManage Server Administrator is what you would want to look at. There is also OpenManage Enterprise that can aid in management of larger device volumes. There is also PERCCLI for interfacing with the RAID controller from the OS. It doesn't look like we have a 6.7 image for the Xr2, based on the support page, but if it's up and running, you should be good. To use OMSA, you need the software agent installed on the host, and then another instance installed in either a Linux (with desktop) or Windows environment. You can use this to manage the VMware server by selecting the option to manage a remote node, then entering the IP address. You can also find all your manuals on the support page for the XR2: [URL] OMSA 9.3 (VIB package): [URL] OMSA 9.3 (Windows package): [URL] PERCCLI: [URL] </s>
<s>[INST] we have 3 n3048 stacked in a rack, this is our backbone. one of the 3 had ftlx8571d3bcl gbic that connected fiber to another dell switch across the street, same model gbic. that dell switch across the street was going bad, so we were replacing it with a unifi switch, and it did not seem to like the gbic, so we replaced both with unifi 1 GB gbic. everything looked good for couple of minutes, the unifi came up, but then it looked like the unifi went offline. then someone came running to tell me the entire network was down. since the only thing I did was replace that gbic, i put the old one back in place. within couple of minutes the network came back up. connection to across the street still offline. only error I found on the dell switches in the rack was: _soc_mem_array_sbusdma_read: FP_COUNTER_TABLE.ipipe0 failed(NAK) could this error have been caused by the replacement gbic, or is it a coincidence? [/INST] Hi, It looks like a memory error which could be from the transceiver change. It is possible that the Unifi one isn¡¯t compatible and was causing an issue. You could try updating the firmware on the switch when you have a maintenance window. </s>
<s>[INST] Hello, I have two N3048P switches which are already stacked together. We have 3 other N3048P's installed in the same rack that for one reason or another are operating on their own and connected to the existing stack with SFP cables. I'd like to add these three switches to the existing stack & have purchased the cables to do so. Each switch has roughly the same config and carry the same vlans. They're also all on the same firmware, boot and CPLD versions & I have backups for each switch already. A couple of questions: 1. What happens to the port config of the 3 individual switches? Will the ports just get renamed from Gi1/0/1 to Gi3/0/1, etc and retain their config? 2. Should I introduce one switch at a time to the stack or can I connect them all at once? Any and all help appreciated! [/INST] Hi, The config from the master of the stack will get pushed to those switches, their existing config will not be used. All at once should be fine. </s>
<s>[INST] i have a dell force10 s4810, i need to make 5 connections with 40gbs, but this switch have only 4 of them. there are alot of 10gb (available sfp+ ports) can i configure a 40G QSFP+ to 4xSFP+ and achieve a 40gb for 5 servers [/INST] Hi, Unfortunately this won¡¯t work, the cable can split a 30Gb port into 4x10 but not combine ports the other way. Your best option is buy a switch with more 40Gb ports, you could also use a quad port 10Gb NIC in the server and do link aggregation to 4 of the 10Gb ports. </s>
<s>[INST] Hi, we have the following problem. In a RAID1 array with 2 400-AEIB SSD disks, both disks showing "Remaining Rated Write Endurance 4%". We have already bought 2 new disks for replacement, but we don't know which procedure is to follow. Should we wait until the first disk fails and then replace it? Should we remove one of the disks, install one of the new disks and the rebuild starts automaticall? Or is there any other procedure? Thanks in advance for any tips [/INST] Hello I would recommend making sure the firmware on the drive and controller are at the latest revision. You should also make sure you are using the latest version of the application used to monitor endurance. Updates may change how endurance is calculated or reported. It may also fix issues of incorrect reporting. If both drives are at the same percentage then I would replace them now. If the endurance is accurate then once the drives reach 0% they will become read only. If you wait until that happens then whatever data is being written at that time may be corrupted. I would replace one drive and then the other. If the storage controller and RAID level support a consistency check then I would run a consistency check before replacing any drives. A consistency check will verify virtual disk information and attempt to correct any faults that are found. [URL] [URL] Thanks </s>
<s>[INST] We have a Networker 18.2.0.1 install with 1 central server and 2 Storage Nodes. The central server is now running Windows Server 2016, but the storage nodes are still running Windows 2008R2. The storage nodes are currently physical and serving double duty for both DataDomain and physical tape libraries and as part of the process we intend to seperate the DD hosting to a virtual machine. This morning I tested creating a new device on the existing Datadomain from a new Windows 2019 VM, which worked and I was able to carry out a backup to it, but caused all of the DD devices on the existing Storage node to flag as 'Suspected'. I've tried to confirm if a DataDomain appliance can only be accessed by a single Storage Node, but my google skills have failed me. Can anyone confirm this, or should it have worked but maybe I've done something wrong? Also any general advice on how I might tackle this upgrade/migration would be very welcome. I previously upgraded/migrated the central server by building a new VM, copying the networker folders, and renaming and ReIPing everything the same but was sure there was a less drastic way for the storage nodes. [/INST] Fast forward several months.... I've since upgraded the firmware on our DD appliances from 5.7 to 6.2 (via 6.1) successfully, and upgraded Networker from 18.2 to 19.2 I tried this same process again today, and it worked immediately, with no suspect devices flagged - so it's now just a process of some further testing, switching backups to new storage nodes and waiting out the retention times I strongly suspect it was the very old DD OS that was the source of the original issue, but I'm very happy the issue is fixed regardless of the cause. </s>
<s>[INST] Hello, I have an Dell R520 server which now contains an Perc H310 controller on the motherboard, I bought an Perc H710P which should be compatible with this server. However when I switch the controllers I get : PCIe Training Error: Integrated RAID I have tried a lot of things to get this to work, and am running out of options. Am I missing something simple? kind regards, Martijn [/INST] That would certainly indicate to me that the issue is with the card, considering it works fine with the H310 and they'd be using the same slot. The only thing I'd be able to suggest at this point is to replace the H710P with another. </s>
<s>[INST] I have a bit of a strange issue with the dedicated management interface on an S6000 version 9.13 I have physically connected the management port to dedicated switch (untagged VLAN) The same VLAN is configured on the S6000 switch. What is strange is unless I add an IP to the interface VLAN on the S6000 the management traffic is very hit and miss. I may lose 70-80% of pings. As soon as I add a random non routable IP to the interface VLAN I dont lose any traffic. Anyone else come across this before? [/INST] Hi, Usually we recommend that the management port be on a VLAN that the rest of the switch isn¡¯t using. It has its own routing table, so it might be creating a loop with itself. </s>
<s>[INST] I've just spoken with Dell Sales as i'm looking to purchase a Poweredge T140 and have a spare PERC H330 mini which I'd like to use with it. I was told that this isn't possible as from the factory it would be set to software raid only and it's not possible to upgrade. I noticed other discussions going back several years which state that it is possible to upgrade and Dell sales are incorrect. Is this the case with the T140? Any help is greatly appreciated [/INST] Hello I show that the H330 is supported on the T140, so it will probably work. Upgrading from the embedded controller to a hardware controller is not supported because we don't carry kits or sell the necessary parts to perform the upgrade. The only way to acquire the parts is by purchasing parts from our warranty stock through spare parts sales. There is no process or procedure to make this change, so there is not a part list of all necessary parts. The parts needed may change based on your configuration, so you will need to research the configurations to find what parts are needed. Thanks </s>
<s>[INST] I have an old PS4100 SAN replicating to a secondary DC. The SAN contains 7 ESX datastores, they are all replicated and I have been asked to test a restore. Looking in EqualLogic group Manager in the Inbound Replicas list on the target SAN, I only see the option to promote replica sets to volume. I need to set a replica online at the target site, there is an ESX cluster there that has iSCSI connectivity to the SAN so I can mount the volume using CHAP authentication. Is the procedure outlined somewhere? Is it a matter of promoting to volume a replica set, mount the volume in ESX and then import VMs? Once I am done with the restore test what should I do with volume? [/INST] Hello, The process is not documented. But if you have enough space you can clone a replica and bring that online. Otherwise you will need to PAUSE replication and promote a replica instead. Then you can set the ACL to whatever you wish. Then point the ESX server at the DR Group IP. Then rescan to login that replica volume. Then you can do "Add storage" to resignature the VMFS Datastore. If you don't do that you won't see the Datastore. After resignature it will then show as 'snapshot-OLD-UUID-DatastoreName' You can then browse, register a VM or VMs and run your test. When you are done you want to un-register the VMs. Unmount the Datastore in ESXi. On the EQL Dr site put the clone OFFLINE. Then on ESXi side do a rescan again. Now you can delete the clone on DR side. Regards, Don Note: Older versions of ESXi iSCSI networking did not support routing. So if the DR goes through a router you can Discovery the volume but never connect to it. I believe it was 6.0 that added that capability. </s>
<s>[INST] Hello Community, this is an urgent issue please. We have a DELL PowerEdge R720 : Raid10 with 6HDD SAS 600GB. 3 spans are present. Two disk (Disk0 and Disk1 on the Span 0) had endured some kind of a physical damage and are out of service, removed! Disk3 is showing a S.M.A.R.T Error. PD Managements showing a foreign configuration on each hard drive. VD Managements showing No configuration present. How can I recover from a similar situation? can I recover data by inserting 2 new drives replacing the damaged ones and importing configuration? How Can I proceed? If data is not recoverable, Can I insert 6 new disks and reconfigure my system, then install an Acronis backup image? Thank you. [/INST] Based on your description, it sounds like a complete span, span 0, is down. If that's the case, then recovering this array won't be an option. You'll need to create a new one using your back up. A RAID 10 is only recoverable if one drive in the span fails. You only need to replace the failed drives, though. </s>
<s>[INST] Hello We have noticed, that we see in the device overview, hostnames instead of iDRAC names in OME 3.2.0. Was this behavior always like this? We are pretty sure, that we have seen iDRAC names in the device overview in the previous version. This behavior brings us two problems: 1. DELLEMC SupportAssist Enterprise collect this information, but of course, it can't connect to a device with the hostname. Because it's not an iDRAC. So we have tons of errors in the Support Assist. 2. OME cannot read the hostname (example XEN-Server) from the overlaying OS, so we see only IP-addresses under the device overview for this devices. Regards [/INST] Hi Virtuatek, I also noticed this change. I think the instructions you need are here. [URL] Essentially it's - OpenManage Enterprise > Application Settings > Console Preferences Expand the discovery settings and change the option for Server Device Naming to iDRAC Hostname. Dan </s>
<s>[INST] So I have recently been restoring and cleaning out and old 2006 Power edge 1900 and when I got it it was missing one cpu and only had one 1.86 ghz processor inside of it so I bought two Intel Xeon X5450 - 3 GHz (EU80574KJ080NT) SLASB SLBBE 1333 MHz (Socket: LGA 771 CPU) (from ebay) Is there any way I can get them to work together. My screen said that it was an incompatible CPU combination and then it said. System Halted! Did I order the wrong ones? where can I find the correct 3.00Ghz processors for socket LGA 771/ Socket J. Thanks! [/INST] Hello I don't show any 54xx CPUs in the part list of the 1900. The CPU that can be used may depend on the revision of the server. I suggest checking the documentation on the system support page. There is an information update document on the support page that states a mark II system is required for 5300 series CPUs. [URL] Also, support for a family of CPUs does not mean every CPU in that family is supported. Skimming through the part list, it looks like the X5365 is the best CPU available. It is part number HP810. Thanks </s>
<s>[INST] I have one server, a PowerEdge R530 with iDRAC8, that I am unable to associate a firmware baseline with. During troubleshooting I created a test baseline targeting just this one device and the Check Compliance task fails with no data in the report. Is there a log file somewhere that might give me a clue as to why things are failing for this one device? In all other respects, OME is able to communicate with this device without issue including running a hardware inventory. I'm on OME 3.2, iDRAC is on the latest firmware (2.63.60.61), BIOS is not current (2.3.4). Only apparent hardware "issue" is that the Service Tag is not being reported in either OME or iDRAC. [/INST] Hello The audit log will show the user and task that is submitted. It may have additional information about what is happening. The issue is likely with the service tag. The service tag is a field that is populated in the compliance report. If a null value is returned then it may be causing the compliance task to fail. If you are not being prompted to enter a service tag when the system starts up then you will likely need an onsite technician to set a service tag. Thanks </s>
<s>[INST] Hi! While updating system using bootable iso PER730_BOOTABLE_19.07.00.55.iso got error: Device: THNSF81D60CSEApplication: Firmware for - Disk 1 in Backplane 1 of Dell HBA330 Mini Controller 0The operation failed due to an invalid image file. The current fimware is DAC9 and package firmware is DACB. I have esxi at server so can't update with windows updater. Regards, Ivan [/INST] I would recommend connecting to the iDRAC and uploading the .EXE update package directly to the iDRAC under iDRAC Settings > Update and Rollback, so that you can bypass your OS and update the drive. [URL] </s>
<s>[INST] Hi All, I have two servers connected to the SCv2020 with 10G Ethernet adapters on the servers side and iSCSI HBAs on the SCv2020 side. Below are the screenshot of how Fault Domains are configured. [IMAGE] [IMAGE] [IMAGE] From GLR630HOST01 I can ping 192.168.11.121 and 192.168.12.121. From GLR630HOST02 I can ping 192.168.11.122 and 192.168.12.122. However, when I try to Create Server I get this: [IMAGE] [IMAGE] Did I configure iSCSI HBA Domain 1/2 or iSCSI Embedded Domain 1 wrong? Thank you. [/INST] Hello Nightwolf_82,Since you are not using a switch your ports are not being recognized. Refer to page 43 under Connecting to iSCSI Host Servers of the Dell Storage Center SCv2000 and SCv2020 Storage System Deployment Guide:[URL] It states in section d: Use the iSCSI cabling diagrams to cable the host servers to the switches. Connecting host servers directly to the storage system without using Ethernet switches is not supported. SCv2000 Series Installation Videos[URL] </s>
<s>[INST] My dell compellent is not up and the ports are down..what could be the cause of failure? or any hardware issue? pls. help me with this thank you. [/INST] It is not possible for me to give you proper analysis via a forum. I would suggest you call in to support to get assistance. They will be able to check your down controller and give you a root cause of the failure. 1-866-397-8673 </s>
<s>[INST] Hi guys, I'm trying to re-setup Dell SCv2020 from the scratch. I'm trying to release the last disk and delete the disks folder but can't see Release Disk option in the context menu for that last disk. [IMAGE] Just wondering if it should be like this. Thanks. [/INST] Hello Nightwolf_82,It looks like you are releasing all disks on your system. In general there are 5 disks in each system which hold the configuration files. As you can see there is a small amount of data on this disk which is most likely configuration files. If you want to reconfigure the system completly then refer to page 301 of the Dell Storage Manager 2016 R3 Administrator¡¯s Guide: [URL] a Controller to Factory DefaultReset a controller to apply the factory default settings, erase all data stored on the controller, and erase all data on the drives.PrerequisitesThe Storage Center must be an SCv2000 or SCv3000 series controllers.The controller must be running Storage Center version 6.7 or later. There is step by step procedure on that page. Remember - Resetting the controller to factory defaults erases all information on the controller and all data on the drives. </s>
<s>[INST] Hello all,I'd like to know if you guys could help me on it.I have a scenario, where I will add a PS 4100 to my site DR. In my site DR, I have a PS as well and I'd like to make an integration.The purpose of the integration is that I bought a Dell EMC SCv3020, created a new SAN and now I have it as my production environment. Before the acquisition, I was with PS 4100 in this position.Could you guys tell me what the best practices to make this integration? Will I have to make a new discovery to found the PS 4100? What information will I need to make a health integration? Will it be necessary to erase the PS 4100 old configuration before make this integration? What requirements will I have to complete to make a successful integration? I'd be very delightful if you guys could take out this doubts.Have a wonderful day. [/INST] Hello, That is very easy to do. It is part of the design of PS storage arrays. You can easily add more members. What is the firmware on the array at DR now and the one you are adding? If they are close you can run setup on the new 4100, and you will specify the Group IP address of the existing group. It will then ask you for the MEMBERSHIP password. This maybe the same as the GRPADMIN password it depends on who set it up. Once you add it to the group, you can manage it now from the same GUI. Configure the other network ports, set the RAID policy and so forth. it will inherit the group information automatically. Once you have it in the group, you want to make sure you upgrade them both to EQL firmware 10.0.2 if you plan on using replication with the SC array. Which is a key benefit to SC and PS storage. The SC array should be upgraded to current revision as well. Regards, Don </s>
<s>[INST] Hi, We have two spare disks in a PS4000 raid. One is marked "spare" and the second became "offline" without any errors. Do you think the "offline" disk will go online automatically if the the other one fail ? regards. [/INST] Hello, You are very welcome. Check the array events screen for any messages when you insert the new spare. Regards, Don </s>
<s>[INST] Hello Need some assistance with an MD3200 we have. It is connected to the server (Dell R710) via SAS cable to a Dell Perc 6/E card. I've set it up so it has a virtual drive and have set a host mapping but in Disk Management it never shows the storage in Disk Management. The host mappings are set like this [IMAGE] Any clues as to what I am missing please? [/INST] Hello AlpsUk, You need to use a SAS HBA instead of the PERC card. Your MD3200 needs a 6GB SAS non-raid card. The issue is that you have configured your setup correctly, however since you have your MD3200 connected to a PERC card, your PERC is not able to present the virtual disk to the host. Here is the link to the support matrix & if you look on page 13 it lists out the supported sas hba¡¯s. [URL] Please let us know if you have any other questions. </s>
<s>[INST] Hi, I have a large saveset (130TB) and a folder within (~70TB) called "Temis" and would like to exclude this folder, all files and subfolders, so that I can back up the Temis folder as a seperate NDMP policy (from Isilon to Data Domain, and also clone to tape)I have created a directive to exclude the folder and files / subfolders but every combination I try and test, the folder backs up. The unsuccessful examples I have tried (amongst numerous others) are: << /ifs/Dublin/GnG/MIXED/archivelonisicl02/Temis >> +skip: * .?* << /ifs/Dublin/GnG/MIXED/archivelonisicl02/Temis >> +skip: *.* Would anyone be able to provide the correct directive text to exclude all files and folders inside the path below: /ifs/Dublin/GnG/MIXED/archivelonisicl02/Temis Many thanks, Stuart. [/INST] You cannot use directives with NDMP save sets. You must define each path by itself. Why? - because no backup client/agent can be installed who could help you reading and following it when creating the worklist. This is general NDMP behavior and not even NW specific. </s>
<s>[INST] Hi, I need a 10Gbps fiber trunk between a PC8024 and S5148F-ON. The connection never comes up. Is there any settings I should be aware of? Link flaps on PC8024: <189> Jul 4 12:13:10 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31380 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:10 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31379 %% Link Down: Te1/0/24<189> Jul 4 12:13:09 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31378 %% Link Up: Te1/0/24<189> Jul 4 12:13:09 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31377 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:09 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31376 %% Link Down: Te1/0/24<189> Jul 4 12:13:08 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31375 %% Link Up: Te1/0/24<189> Jul 4 12:13:07 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31374 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:07 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31373 %% Link Down: Te1/0/24<189> Jul 4 12:13:07 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31372 %% Link Up: Te1/0/24<189> Jul 4 12:13:07 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31371 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:07 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31370 %% Link Down: Te1/0/24<189> Jul 4 12:13:06 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31369 %% Link Up: Te1/0/24<189> Jul 4 12:13:06 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31368 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:06 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31367 %% Link Down: Te1/0/24<189> Jul 4 12:13:06 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31366 %% Link Up: Te1/0/24<189> Jul 4 12:13:05 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31365 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:05 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31364 %% Link Down: Te1/0/24<189> Jul 4 12:13:05 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31363 %% Link Up: Te1/0/24<189> Jul 4 12:13:04 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31362 %% Link on Te1/0/24 is failed<189> Jul 4 12:13:04 san-sw2-1 TRAPMGR[248325744]: traputil.c(638) 31361 %% Link Down: Te1/0/24 show fiber-ports optical-transceiver Output InputPort Temp Voltage Current Power Power TX LOS[C] [Volt] [mA] [dBm] [dBm] Fault-------- ---- ------- ------- ------- ------- ----- ---Te1/0/24 39.5 3.326 26.0 -1.598 -2.307 No No Link never comes up on S5148F show interface eth1/1/46Ethernet 1/1/46 is up, line protocol is downDescription: Link to oldHardware is Eth, address is d8:9e:f3:cc:8c:2eCurrent address is d8:9e:f3:cc:8c:2ePluggable media present, SFP+ type is SFP+ 10GBASE-LRWavelength is 1310Receive power reading is -1.550881 dBm Regards Thomas [/INST] Hi Josh. Opened a ticket and changed interface. Now it works. Thanks for your suggestion though. /Thomas </s>
<s>[INST] Hello, I installed the OVF yesterday and setup OME 3.1. If I create a custom report, then click on run and email, I get receive the email with the attachment, brilliant I know SMTP is working. I then went and pulled one of the power cables from a server to generate an alert. Sure enough on the dashboard I can see "Critical: 1" however I am NOT receiving an email for the alert. In alert policies, I have Email checked and correct email settings, but still not receiving the email. I have deleted the email alert and re-created but it is still not sending an email [/INST] [NAME], It is possible that the notification that you see on the dashboard is an internal alert generated by OMEnterprise, when it sees that one of the servers cannot be reached. Can you try choosing the "Application" category / "System Health" subcategory in addition to other categories you have selected and see if you are able to get the email? #iwork4dell </s>
<s>[INST] Hi, i am trying to clone manually severals save sets with nsrclone to the 'historic pool' on tape but the command throw me than the pool doesn¢¥t exist. the command is: nsrclone -s networkerserver -b 'historic pool' -S -f 3860360225 the error is: nsrclone : unable to query RAP DATABASE for clone pool resource: NO NSR POOL resource found with the name 'historic' pd: the save sets than are trying to send to the tape there were on waiting to run state. [IMAGE] Thanks in advance. [/INST] Can you try using double quotes - " instead of single quotes - ' in your command ? </s>
<s>[INST] Hi, Will c6100 XS23-TY3 run at 1333Mhz if I put 16GB DIMM in the 12 Slots at 1333Mhz each? I can't find the document for the memory configuration for c6100 XS23-TY3, which I have used in the past. I'm finding in internet ([URL] some copy and paste from this old documentation, but it's only partial and not giving enough info for my question. [/INST] Hi, I'm writing only for others like me, to know the outcome. At the beginning, I have started my question with "I can't find the document for the memory configuration for C6100 XS23-TY3, which I have used in the past." and have give you the direct links for the documentation that is available at that moment and that this is not the same documentation for which i'm looking. You Dell-DylanJ, have failed to give the correct answer, for which I was asking the Dell support. The answer is Yes, it will run at 1333 Mhz if you put 16GB DIMM in the 12 Slots at 1333Mhz each. In my case, I have used 12 x "M393B2G70BH0-YH9 SAMSUNG 16GB (1X16GB) 2RX4 PC3L-10600R DDR3" memory modules. Once again, I am disappointed with the support we rely on so much that it can help us and save time. After giving me your pointless answer, I had to physically take the server (which is quite heavy) to a second-hand company that had the memories in question, which was not easy to find. Asking them to test if memory will work after the manufacturer's support cannot provide a clear answer to such a simple question. </s>
<s>[INST] Regarding our enviroments,There are NFS export from isilon to AIX.please suggest us about free space and use space. On isilon,I have already limit hard quota that is directoy bayapp is 500 GB. Details as below. [IMAGE] Now percent used is 82.08% but i saw on AIX server that path is map NFS from isilon.it 80 percent from isilon quota and limit not properly as i expected. Anyone can suggest about this or recommend i to do the best practices do quota limit for NFS exports. [IMAGE] I'm looking forwards to hearing from you soon. [/INST] What I normally set is Hard limit, I exclude the Snapshot data and Dataprotection overhead to not have those to take space of the quota. I also set "Show available space" as Size of hard threshold, cause else the users se the size of your whole Isilon cluster. even though they have the Hard quota. Thats how my BP looks like. //Gunnar </s>
<s>[INST] Dear Sir, Due battery loss we have Replaced RAID Controller Module 0, card but after replaced RAID Controller Module 0 we are getting below error on RAID Controller Module 1.So can you please suggest me for the solutions. Storage array: IMS_MD3220i_2Port reporting problem: RAID Controller Module 1, Physical Disk Channel 1, Port: 0Status: SAS Port Failed Physical Disk interface: SASChannel: 1Port: 0Part type: LSISAS2116 revision 223,036,928Status: FailedMaximum data rate: 6 GbpsCurrent data rate: Not availablePhysical Disk interface: SASChannel: 2Port: 0Part type: LSISAS2116 revision 223,036,928Status: UpMaximum data rate: 6 GbpsCurrent data rate: 6 Gbps --- Also I have tried with below command but no luck by run below command. smcli IP -c "clear allPhysicalDiskChannels stats;"smcli IP -c "set physicalDiskChannel [1] status=optimal;"smcli IP -c "set physicalDiskChannel [2] status=optimal;"smcli IP -c "set physicalDiskChannel [3] status=optimal;"smcli IP -c "set physicalDiskChannel [4] status=optimal;" [/INST] Hello All, If any face the RAID Controller Module 1, Physical Disk Channel 1, Port: 0 error after insert raid card so you can reset the card We have resolve the issue after reset RAID Controller Module 1. </s>
<s>[INST] After updating to 3.2.0 (Build 241) I can no longer create or edit a report. All goes well until I click finish when I get an error in white text on a red background stating "An unknown error has occurred. Please try again." Existing custom reports still run but I can no longer create new ones or edit existing ones [/INST] [NAME].harris Sorry to hear that you are not able to edit or create custom reports post upgrading the appliance. Can you please check if post upgrade task is completed post upgrading the appliance to 3.2 Also please clear the cache of the browser and check if you are have upgraded the Browser to latest version and try creating the report or editing the report as we not able to reproduce this issue in 2 different systems Thanks, Anil Kumar V K R Dell EMC #iworkforDell </s>
<s>[INST] I have a pair of identical R820 systems. I upgraded the iDRAC on the first unit from 2.61.60.60 to 2.63.60.62 without any problem. I then attempted the same from the 2nd unit, but the iDRAC would no longer respond afterwards. The update dialog on the 2nd unit went like this and seemed to finish ok. .... iDRACThe version of this Update Package is newer than the currently installed version.Software application name: iDRACPackage version: 2.63.60.62Installed version: 2.61.60.60....Device: iDRACApplication: iDRACUpdate Successful.The update completed successfully. ... I then did a cold boot of the system, the Lifecycle Controller shows as DISABLED, and later the message "iDRAC initialization error" appearsManagement Engine Mode: ActiveManagement Engine Firmware Version: 0002.0001Patch: 0005Build: 00A7F1 to continue, F2 to run setup. The OS will boot, fans on full blast. I tried running the firmware update a 2nd time, but it just times out. I've tried recovering from a DRM created SMART ISO and a PER820 Platform Specific Bootable ISO, but both of those hang during inventory collection. I was able to boot into a SLI ISO. The BIOS and H320 controller firmwares are already the latest. However, DSU refused to update the iDRAC complaining of a "partial inventory". I've already tried powering the system off and "flea" draining the power from the iDRAC. What's the next thing to try to recover the iDRAC? SUU? Any other suggestion or more detailed steps to try? [/INST] And... I fixed it! "PowerEdge: iDRAC Recovery Procedure with firmimg.d7" was key to re-enabling Lifecycle services. The imediate noticable improvement was the iDRAC would report Done right away after the memory was configured. I would still get the iDRAC initialization failed message later on. Hit F10 to enter the Lifecycle services and reset the iDRAC configuration to default. The rest is a few reboots and re-configuring the iDRAC (or System) settings. To get the firmimg.d7 file, download the iDRAC firmware for Windows. It can be extracted using "unzip -L ". Unzip it in a subdirectory because it does not create its own. The firmimg.d7 file is under the payload directory. I did clear the NVRAM at one point with the jumper, but that didn't seem to help. I'm not sure if it contributed to the final solution. </s>
<s>[INST] Hi folks, Am wondering if anyone out there has experience with Unity and IBM iSeries? I have a customer who is running an iSeries on V7R3 (internal disk) and are trying to connect to a Unity file share via QNTC. The file share is mapped but none of the directory structure is displayed. Per IBM's instructions, the user connecting to the share is the same and has the same password. Wireshark traces to the share from the iSeries show the Unity sending a [FIN, ACK] after credentials are sent. Customer has this working with Synology and other Windows servers with no problems. Any ideas? [/INST] Hi Sam, After putting in a ticket with Dell, it was related to KB 000033501 - Dell EMC UNITY, VNX: AS400 SMB Client Access Denied to Unity/VNX CIFS Share (Dell EMC Correctable) Our previous AS400/iSeries (that is working) is on OS v7r1 and must be running local authentication on the NAS. This new build AS400 that was having the problem is OS v7r3 and defaults to SMB2. One of Dell's engineers updated the parameters on our NAS and the shares started working to our AS400 again. </s>
<s>[INST] Hi! We have a PowerEdge R715 server that's configured with a RAID5 (6 SAS 600GB disks). One of them is showing a predictive failure message. I have another disk that was removed from another server, but I don't know if it was cleaned before removal. I've been reading some material this morning and basically, what I have to do is: Is that ok? Is there a problem if the disk isn't cleaned up? I need to reboot the server to set the disk as a Global Hot Spare? What about this option: Replace Member Disk...? [IMAGE] [/INST] Hello, The replace member disc option is a way for you to manually replace the disk. You can also remove the bad one, insert a new one, and if it doesn't automatically begin to rebuild, just mark the new drive as a global hot-spare and the PERC will do the rest automatically. All of this can be done from within OpenManage Server Administrator (OMSA). If the drive has data on it presently, you might have to choose to "Convert to RAID" for the drive, depending on the drive source. </s>
<s>[INST] We recently configure remote syslog feature. We were doing some testing with accounts. Testing was carried out on this area which included account creation, modification and deletion for each IDRAC account. When I checked this in remote server, I did not see any events being generated for each action. Password changes carried out by tester were also not logged in remote server. When I alter the idrac accounts, despite seeing these changes recorded under the Lifecycle Log, we don¡¯t get anything sent to remote syslog. Under alerts we have all check boxes ticked under ¡®Remote System Log¡¯ under all 19 pages. Can you please confirm if this is by design or if we may have missed something? Thank you [/INST] This is the help descriptor from that page, indicating that the RAC and SEL are the only components that would be sent to the syslog server. As you mentioned, the Lifecycle log catches these, but does not appear to be included in the syslog's export. The Lifecycle controller log can be exported using the following: If you want regular updates, you might put that into a .bat file and then schedule it to run every so often with the task scheduler, or set up a cron job, if it's a Linux environment. </s>
<s>[INST] Hello Everyone! I Have Posted before about an issue I had with my Poweredge R710 Server that I had issues with related to the HDD's. Anyway I was installing Windows Server 2012 and was able to see the 2TB Raid 0 HDD but when I attempted to install it said "We Couldn't Locate An Existing Or Create A New Partition". If you have any experiences similar to this or know how to fix this any form of help would be great. I plan to boot this from a USB flash drive (or low cap. SSD with a laptop DVD to SATA adapter) and if I am able to install on another device and load drivers for the raid card (SAS card, SATA Backplane) onto win server 2012 so that it can access the storage I have. Thank You [/INST] Can you use NAS/laptop/desktop drives? Maybe. There is no guarantee. Some drives may not show up on the controller at all. Some may show up but can't be configured. Some may show up and be configurable but fail randomly later. They simply aren't programmed to respond to the controller like the controller expects, so whether they work or not will be hit and miss and you would just need to try it, assuming that roadbumps you encounter are a result of the drives not being the proper drives for the server. </s>
<s>[INST] I have a R620 with a bad iDrac enterprise and it looks like a motherboard replacement is the only solution. The label on the motherboard shows that it is a 0VV3F2. Will a KCKR5 be a suitable replacement for it? [/INST] Itmalic, The issue is that the VV3F2 board is a newer version (Version 6) than the KCKR5 (Version 2). So any other hardware based off that difference can cause issues. </s>
<s>[INST] Hi, can it happen that a shipped SP has a different OE/ or a shipped SP contain an OE lower/higher than the array ? Many THanks, Vivek [/INST] Hi [NAME] Thank you for your reply. As a precaution the Unity arrays has a set of drives that hold a copy of the code and are used as Vault drives, more specifically drives 0 to 4 of the DPE. When the internal SSD is replaced on a Storage Processor, the system will then install the OS into the new M.2 SSD. I hope that this information is useful, however if you have any other queries, please let me know by replying to this message. </s>
<s>[INST] Hi guys, On SCv2020 I have nothing connected to SAS ports and have no intention to plug in an additional enclosure. Should I ignore these kind of warnings? [IMAGE]Thank you. [/INST] The SCv20x0 require 2 SAS cables cross connected. If you have nothing connected you have setup the system in a wrong way. This is different compared to the newer SCv30x0,50x0 and 70x0. Regards,Joerg </s>
<s>[INST] Dear Support, You know there are some area has restrict network, it's very slow to pull image from repository or even no access to them. So can team develop an offline installation guide or offline package for CSI driver? Even though I installed it, but I found most of issue are about network, waste to many time. Thanks [/INST] Hi Fan, In every k8s infrastructure, you will need to have access to one or multiple container image registries. If you need to push the Docker Hub image to a private network, one easy and manual way to is to : 1. Pull the official image with : docker pull dellemc/csi-vxflexos:v1.1.0 2. Tag it to your new registry : docker tag docker.io/dellemc/csi-vxflexos:v1.1.0 my_private_repo:5000/csi-vxflexos:v1.1.0 2. Push it to your private registry : docker push my_private_repo:5000/csi-vxflexos:v1.1.0 3. Update the helm myvalues.yaml (which a copy of : [URL]#L52) to point to your private repo HTH </s>
<s>[INST] Hi, I'm using two S5048 in VLT configuration mode that are to act as DHCP relays forwarding the requests to a central DHCP-server that are located beyond OSPF-routing in another geographical location. The problem is that the S5048 relaying are using their loopback IP-addresses (for OSPF routing to the remote network where the DHCP-server resides) as source on the unicast to the dhcp-servers and not using their IP-addresses on the VLAN where the originating DHCP-discover is sent by a client. Which fails since the Windows DHCP-server can't pick the correct DHCP-scope for the end-client. This has been verified with packet-captures on the server. I have also verified that they are forwarding the requests by enabling debugging in FTOS for dhcp relay. Anyone seen similar behavior? [/INST] Can mark this as resolved.It's a FTOS version issue. The switches were running 9.12, with 9.14 one can configure the source-interface for each vlan combining that with: ip helper-address [vrf ] Syntax example: conf t int vla 10 ip helper-address 192.168.1.1 ip dhcp relay source-interface vlan 10 </s>
<s>[INST] Hello, does anyone know a way to display the metadata usage (as a %) via command line? We have scripts collecting data from Avamar systems and we want to be able to pull this information. I have a couple of Av/DD setups, where lots of directories and very small files are backed up to DD. This uses more metadata on the Avamar, so the metadata usage is higher that normal GSAN. This would be common for AVE/DD setups where all data is backed up to DD and nothing (except metadata) on Avamar itself. In MCGUI it displays the higher percentage (between metadata and server utilization), and can see both if I click on it. (see pic below). But mccli server show-prop only shows the server utilization. Is there any command to display the metadata utilization percentage? Thanks and regards, Stephen [IMAGE] mccli server show-prop Attribute Value-------------------------------------------- ----------------------------State Full Access..Server utilization 1.7% [/INST] Try mcserver.sh --status | grep -i metadataUtilization </s>
<s>[INST] I'm going to add new server to do stress specific work and this server should be T640. I'll insert in configuration a PERC H740P or H730P+ with two disk RAID 1, and would like to be sure that the controllers will be recognized by Ubuntu 18.04 installation, as in previous one purchase the PERC controller was not compatible and i had to install the OS disabling it via BIOS and using software RAID management. I've read documentation in dell site about the compatibility and should be ok, as 18.04 result compatible, but i prefer to be very sure, so i ask if the PERC controllers is compatible with 18.04 Ubuntu installation. I've also found some post that suggest to get UEFI BIOS and not Legacy BIOS as the last one can cause problems in installation. Is that true? [/INST] Good morning, [URL] That link explicitly calls out Ubuntu Server 18.04 as a supported OS. There should be no issues with installing Ubuntu to your T640. </s>
<s>[INST] equallogic PS6100. have two of them, one syncreps volumes to the other. i have this one thin provisioned volume that I store some linux servers on. this volume is growing by 3% every day for the last few days, up to to 77% in use space now. although I could just add more space to the volume ( I have plenty free), doesnt change the fact that it continues to grow. not 100% clear on what causes the growth, but I think Eql doesnt allow you to reclaim space after it writes to block? I have 13 VMs stored on this volume, total HD space for all of them is 904 GB. Vmware shows 3 TB Datastore, 989 provisioned, 2 TB free. EQL shows in-use 2.31TB, with 7.2 unreserved. unless I change something, it will just continue to grow, so what are my options? change volume so it is no longer thin -provisioned? move everything to another volume? [/INST] Hello, SANs do not reclaim on their own. They can't they aren't filesystem aware. The owner of the volume is responsible for telling the storage what blocks can be freed. VMFS v5+ supports reclaim. AKA UNMAP This VMware KB covers how to do that. [URL] On the EQL side you need FW greater than 6.x. The volume cannot be replicated by EQL using SYNC or ASYNC replication. UNMAP is disabled on replicated volumes on Dell PS Series SANs. But to remove your concern overall. Nothing bad will happen if you use 100% of an EQL volume. In the case of thin provisioning this assumes you have not overprovisioned your actual storage capacity. I.e. you have 10TB of actual space and create a 15TB thin provisioned volume. Once you run out of physical space, the volume goes offline. So let's assume you have not done that. As I mentioned SANs don't know filesystems or files. A server tells the SAN to write or read a block of data. If a delete occurs and no corresponding UNMAP command is sent there's no notification to the SAN to free that block. The OS and filesystem keep track of all the used and free blocks on each volume That allocation table allows the OS to re-use previous blocks. So even if an EQL volume shows 100% in-use, the OS could show 100% FREE. If you filed the volume and then deleted everything. So do not use the EQL GUI as an up to date gauge of free and used space. So when you get to the threshold on EQL side, you do not have to increase the volume. You can also change the warning alert all the way to 100% if you have enough space to hold all the volumes data. Again, NOT over provisioned your actual disk space. Now a funny thing on how OS's vs. SANs are different. When you first create a VM on a 100% free EQL volume an interesting thing will happen. With no thin provisioned VMDKs the array will show MORE free space than VMware reports. I.e. if you create a 500GB VMDK thick provisioned hardly any space will show used on the EQL side. But 500GB will show used on ESXi side. That's because VMware doesn't actually write out 500GB when it creates a VMDK file. Far from it. Over time it will swing the other way as VMs are deleted or moved to another volume. So MORE space will show allocated in EQL GUI vs. VMware. Also until you get to ESXi v6.7 U2 or greater, and native VMFS v6 formatted volumes, when you delete a file inside a VM UNMAP commands from that VM's OS are not passed to the backend SAN storage. Which means only when ESXi deletes a file will space be reclaimed when using the VMFS reclaim process. So temp files, VMDK snapshots, log files, memory dump files, deleted or moved VMs will be reclaimed. So bottom line. Don't go by what EQL shows for in-use space vs. free on a volume. Go by VMware info. Regards, Don </s>
<s>[INST] Hi, I have read almost all posts related with this issue, and I have redistributed (all?) vdisks. Now, I have two VD (100G and 250G), the latter is storing some critcal VMs. and the first one some minor db app. First question: It's safe to redistribute the vdisk while I/O is running on the block device? I have read on another post and one Dell tech reply that "yes". But I'm concerned, I'm running critical infrastructure here. Firmware: 07.84.47.60 - Dell md3200i (no external enclosures) Host os with initiators (open-iscsi) and multipathd(8): Linux. (ubuntu 18.04 AMD64). I have paths that are OK, but one of theme looks like this: (output from multipath -l from linux): size=100G features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 rdac' wp=rw|-+- policy='round-robin 0' prio=0 status=enabled| |- 12:0:0:1 sdaw 67:0 failed undef unknown| |- 15:0:0:1 sdau 66:224 failed undef unknown| |- 16:0:0:1 sdav 66:240 failed undef unknown| `- 18:0:0:1 sdax 67:16 failed undef unknown`-+- policy='round-robin 0' prio=0 status=active|- 10:0:0:1 sdaj 66:48 active undef unknown|- 11:0:0:1 sdal 66:80 active undef unknown|- 17:0:0:1 sdai 66:32 active undef unknown`- 19:0:0:1 sdak 66:64 active undef unknown As I understand this, it has failed over the non-preferred path, which causes the array to complain (the amber light is up, and the message "needs attention" shows up on MDSM). Question #2. If all other paths on other vdisks from the same host (4 more) show signs of no problem then what's going on. However. I believe the issue it's not deterministic, as I have seen (before the redistribution) other vdiss were mentioned in the "Needs Attention" window, I then redistributed those (in the maintenane window, all VMs down, etc.) and haven't saw them again as reported on the non-preferred path. But I have this two now. Yesterday I did a maintenance window and when I redistributed all vidsk directly by going to the Hardware tab, then selecting the controller (this is needed?) then from Storage/Virtual Disk/Advanced -> Redistribute Virtual Disks. Everything was ok, multipathing was working, etc, then like half an hour later 1 path started failing, then another, the two vdisks I mentioned. As far as I know this "redistribution" is a quick fix (is it?) because yesterday I did just that (but not from right clicking on the vdisk on MDSM but directly from the Storage menu that I just put in my previus paragraph.) and then the problem appeared again. What I can deduce is that my host conectivity (4 interfaces 1Gbit/s) is OK, I can ping all 8 ip addresses on the SAN (two for each interface, we use 4 subnets to reach controller 0 and controller 1, which are connected to a dell switch), the host is connected to the same switch. Also another host I have have zero problems with iSCSI, using the same switch and the same SAN, same subnets, same number of interfaces. And, since all other paths are showing as correct and are being used (round-robin) I suppose that the problem it's not on my host. MTU is jumbo as it's correctly setup both from the Linux interface and from the Switch in the middle (dell powerconnect 7024) and from the SAN. Can it be that I need to recreate those vdisks on the SAN side? Also, when doing a wireshark session I can se this message: "LUN Busy" returned from the SAN, I could see this from all interfaces, don't happen all the time but it show up eventually on all of them, is this normal? Thanks I appreciate any insights into this. [/INST] Hello lukes357,The first thing that I would do is to upgrade your firmware on your MD3200i, as the version that you are running was released in July 2013. The latest version of firmware is 08.20.24.60 for your MD3200i. Once you have upgraded the firmware on your Raid controllers and HDD¡¯s then I would monitor the system to see if it happens again. If it does happen after the firmware upgrade, then we will need to review a support bundle from your MD3200i so that we can see what is going on.Here are the steps for doing a firmware upgrade just in case you need them. Controller Firmware[URL] Resource dvd[URL] HDD/ SDD[URL] Firmware Upgrade steps:1. Gather support bundle in MDSM2. WARNING: If you have a single controller PowerVault MD3200/MD3600 series storage array you must stop all I/O operations before starting the firmware upgrade.3. Extract the firmware to folders and remember location.4. Burn or mount the ISO for the resource cd.5. Uninstall the MDSM from hosts (reboot required)6. Install MDSM from resource DVD (reboot required)7. Clear the Major Event Log.8. Update to 07.75.28.60 if not already there, then update to latest firmware.o If you receive an error while checking the SPM database, ensure that you have an out of band management connection to both RAID controllers.9. Verify connection and data.10. Update the hard drive firmware.11. Reboot stack and verify all is optimal.A. Power down the server(s)B. Power down the MD32x0(i)C. Power down any attached storage (MD12xx)D. Leave the power off for 2-3 minutesPlease allow for at least 60-85 minutes for the updates. Time may vary depending on how long each reboot takes.Please let us know if you have any other questions. </s>
<s>[INST] Instead of taking me to the device page, clicking on a device on any screen takes me back to the homepage. Clicking on the device IP takes me the iDRAC login page, which is expected. Anybody else seeing this? [/INST] Hello I haven't been able to reproduce this issue. I suggest clearing browser temp files. If you continue experiencing the issue then list the browser version and specify a location that produces this behavior. I tested these two browsers: Chrome 75.0.3770.100Firefox 64.0 (64-bit) Thanks </s>
<s>[INST] I can login as local admin and test connection to AD successfully, but when I go to actually login with AD credentials, the login just hangs forever. So much for "AD enhancements". Edit: Also just noticed that once the login hangs once, I can't login as local admin anymore either. I have to restart the entire appliance before it works again. [/INST] I was really hoping to avoid having to recreate the directory associations but I went ahead and did it and can confirm it fixed the problem. Fortunately we didn't have too many groups to re-associate. At this point I'm just glad the day ended on a win. Thank you for the quick responses! </s>
<s>[INST] I've read this: [URL] I'm trying to see why a Mellanox MCX-353A-FCBT (Gen3 x8) card, installed in the mezzanine slot is capped to 4GB/s throughput on an (old) PE C6220 motherboard. The mezzanine slot on that motherboard is called SLOT1_PCIE_G3_X16(CPU1). System tools (lspci -nvv -s 3:0.0) show that PCIe link training does indeed occur at 5GT/s (Gen2), which would be a cause for exactly this limit (at x8). In the link above, there is a mention of "the exception of the mezzanine slot, which only supports Dell custom mezzanine cards". What cards are concerned by this exception ? The Mellanox card, which was purchased from Dell with the server, is clearly listed among the supported add-in cards in a Dell document called "PowerEdge C6220 Technical Guide", dated december 2013. Should I understand that this document was wrong, and that the hardware has a design flaw which is the culprit behind my underperforming Mellanox card ? Best regards, E. [/INST] Hello I show that we limited slots 1 and 2 to gen2 because of issues encountered when they were set to gen3. The notes I have read suggest that the mezzanine slot will still operate at gen3. As mentioned in the linked article, only Dell custom mezzanines are supported in the mezzanine slot. I had difficulty locating the mezzanine card that you have installed. I located the model on Mellanox's site: [URL] I checked part 540-BBKI and found that it contained card part # 79DJ3. That card is not listed under the part list of the C6220. It does not appear to be supported in the system. Thanks </s>
<s>[INST] Hello, Is there any process to rollback Vrtx CMC firmware update? I do not see any mentions for the CMC firmware rollback for the Vrtx CMC v3.20 firmware update ([URL] I would like to know if the CMC can be rolled back to 3.1 after updating 3.2 for example. Thank you, [/INST] Hello Yes, you should be able to downgrade to 3.1. You would just install the 3.1 update. When installing an older update there will typically be a warning prompt. Before downgrading firmware you should check the release notes for any information that would prevent a downgrade. I see nothing in the release notes that would cause issues downgrading as far back as 3.0. You can find the release notes on the CMC firmware download page on the VRTX support page. [URL] Thanks </s>
<s>[INST] I have a customer who wants to know if we have any best practices for presenting the Unity Luns to Netapp (FAS8080). They want to know if they can add thick and thin luns to it or if there any constraints. They had originally purchased Unity 650F to use for NAS storage. Due to migration concerns the FAS8080 was used instead to migrate from another system. After further discovery they realized there was not enough disk space in the FAS8080. So rather than purchasing more disk for the FAS they requested the Unity 650F space be provisioned to the FAS8080. [/INST] There arent constraints from the Unity side - there the NetApp is just like any other FC host. This is more of a question what NetApp recommends since they are putting their file system on top of the Unity LUNs They may not support using thin LUNs if they cannot deal with conditions like the Unity pool running out of space.Plus since WAFL always writes to new blocks thin LUNs could become full unless they can do regular space reclaim using SCSI unmap. Also using thin provisioning on two levels on top of each other makes management and monitoring more complicated </s>
<s>[INST] Hi all, I installed the very latest version of RP4VM 5.2SP2 but I cannot protect the VM's through the plugin console. At the end of the process I have this pop-up error : "INTERNAL_ERROR" Everything is green... Cannot see anything in the logs also. Any Idea ?Thank you [/INST] Bingo - please upgrade the plugin via the plugin help menu. Then logout and log into the web client and verify that the plugin is also running 5.2.2. Finally, retry protection. Regards, Idan </s>
<s>[INST] To whom it may concern, Does S4048-ON stack with S4048T-ON? is there any limitaion ? Sincerely, Jessie [/INST] Hi, Yes you can. [URL] User port stacking support for up to six units and unique mixed mode stacking that allows stacking of S4048-ON with S4048T-ON to provide combination of 10G SFP+ and RJ45 ports in a stack. Page 969 [URL] </s>
<s>[INST] Hi, I want to use VLT with peer-routing for our network with following configuration: on S4148FE_S1 === vlt-domain 80backup destination 10.0.18.2discovery-interface ethernet 1/1/27discovery-interface ethernet 1/1/28peer-routing ! interface vlan 100ip address 172.16.56.1/24 ! spanning-tree mode rstpspanning-tree rstp priority 0 S4148FE_S1 ========= vlt-domain 80backup destination 10.0.18.1discovery-interface ethernet 1/1/27discovery-interface ethernet 1/1/28peer-routing ! interface vlan 100ip address 172.16.56.2/24 ! spanning-tree mode rstpspanning-tree rstp priority 4096 Do I need to configure VRRP on this network or it is good? and I have PCs and Servers Connected with these switch, Which IP address would be a Gateway of end devices? S1 vlan IP or S2 vlan IP if there is VRRP? Thanks everyone. [/INST] Hi, You don¡¯t need to use VRRP, you can just point to the master of the VLT. edit: The ARP proxy is not currently available in OS10EE. Dell EMC recommends you use VRRP for gateway redundancy in host-facing VLANs. [URL] Page 9 </s>
<s>[INST] [root[NAME]-master-01 helm]# sh install.vxflexosKubernetes version v1.13.3Kubernetes master nodes: 192.168.18.10Kubernetes minion nodes: 192.168.18.11 192.168.18.12Verifying the SDC installation.Retrieved 1 mdm(s)MDM-ID 39f317742b58aa0f SDC ID 749f21df00000004 INSTALLATION ID 5082d8992e46577b IPs [0]-192.168.18.103 [1]-192.168.18.104Retrieved 1 mdm(s)MDM-ID 39f317742b58aa0f SDC ID 749f21e000000005 INSTALLATION ID 5082d8992e46577b IPs [0]-192.168.18.103 [1]-192.168.18.104Verifying the feature gates.fail: 0NAME: vxflexosLAST DEPLOYED: Sun Jun 23 17:19:59 2019NAMESPACE: vxflexosSTATUS: DEPLOYED RESOURCES:==> v1/ClusterRoleNAME AGEvxflexos-controller 4svxflexos-node 4s ==> v1/ClusterRoleBindingNAME AGEvxflexos-controller 4svxflexos-node 4s ==> v1/Pod(related)NAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ContainerCreating 0 4svxflexos-node-8g2zb 0/2 ContainerCreating 0 4svxflexos-node-swfsl 0/2 ContainerCreating 0 4s ==> v1/ServiceAccountNAME SECRETS AGEvxflexos-controller 1 4svxflexos-node 1 4s ==> v1/StorageClassNAME PROVISIONER AGEvxflexos (default) csi-vxflexos 4svxflexos-xfs csi-vxflexos 4s ==> v1alpha1/CSIDriverNAME AGEvxflexos 4s ==> v1beta1/StatefulSetNAME READY AGEvxflexos-controller 0/1 4s ==> v1beta2/DaemonSetNAME DESIRED CURRENT READY UP-TO-DATE AVAILABLE NODE SELECTOR AGEvxflexos-node 2 2 0 2 0 4s NAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ContainerCreating 0 10svxflexos-node-8g2zb 0/2 ContainerCreating 0 10svxflexos-node-swfsl 0/2 ContainerCreating 0 10sNAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ContainerCreating 0 15svxflexos-node-8g2zb 0/2 ContainerCreating 0 15svxflexos-node-swfsl 0/2 ContainerCreating 0 15sNAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ContainerCreating 0 20svxflexos-node-8g2zb 0/2 ContainerCreating 0 20svxflexos-node-swfsl 0/2 ContainerCreating 0 20sCSIDrivers:NAME AGEvxflexos 20sCSINodeInfos:No resources found.StorageClasses:NAME PROVISIONER AGEvxflexos (default) csi-vxflexos 20svxflexos-xfs csi-vxflexos 20serror: the server doesn't have a resource type "volumesnapshotclass"installing volumesnapshotclasserror: unable to recognize "volumesnapshotclass.yaml": no matches for kind "VolumeSnapshotClass" in version "snapshot.storage.k8s.io/v1alpha1"VolumeSnapshotClasses:error: the server doesn't have a resource type "volumesnapshotclass" [/INST] It would be good to get the logs from the controller, via: kubectl logs -n vxflexos vxflexos-controller-0 driver </s>
<s>[INST] Recently, I fount the front LED is showing FAN0001 Fan 6 RPM is outside of range. But I do not have FAN 6 installed. Any hints? Thanks a lot. [IMAGE][IMAGE] [/INST] Dell_3, The issue normally occurs when the system has an uncertified PCI-Express add-ons card installed, as well as the iDrac being out of date. It is just a false alarm with no functional impact to the system, so you can clear the SEL and it will back to normal till next iDRAC reset or AC power cycle. I would suggest getting the system to current on BIOS and iDrac and the error shouldn't occur anymore. </s>
<s>[INST] Is it possible to take the HHD out of a PowerEdge 2970 (Savvio 10K.3 HHD) and connect some way to a USB? The server die and I just need to get some information off of it. [/INST] Hello If the drive was connected to a RAID controller and was part of a virtual disk, like a single drive RAID 0, then it would be best to connect it back to the same type of RAID controller. If it was connected to something that was just acting as pass-through then yes, you should be able to read the data from an external USB enclosure that supports the drive type. [URL] Thanks </s>
<s>[INST] I have a R440 that I added a PERC H730P RAID card to. Used a Riser 2 type riser. Connected via a mini SAS 8643 to 8643 cable on A0. The server is not detecting the RAID controller. Thank you. Results from DELL EMC ePSA Pre-boot System Assessment: [/INST] Hello Are you trying to switch from software RAID to hardware RAID? Was the system ordered without any risers? It looks like you are trying to install an H730P into an unsupported PCIe slot. Internal PERCs are only supported in slot 1 or the internal slot in a no riser configuration. I'm not sure if they will work properly in any other slot. I don't think we use proprietary SAS cables, so the cable shouldn't be an issue as long as it is properly connected to all necessary connectors. Thanks </s>
<s>[INST] Hi! I Long Ago Bought A Dell Poweredge R710 Server And When I Tried To Install Windows Server It Was Unable To See Any Drives. Because Of This (And The Required Overhead For Windows) I Installed Ubuntu (Desktop, Yes I Know That Is A Bad Move For Servers But This Is A Plex Server) And Could Only See The USB Drive That The OS Was Installed On. I Looked At The Dell Forums And Saw A similar Post Detailing That I Needed To Go Into The Ctrl+R Menu But The Instructions Differed From My Situation From There And I Was Not Able To Change Any Settings That Would Allow My OS To See The Drives. Do You Have Any Fixes To This? The Server's Ctrl+R Menu CAN See The Drives. [/INST] Ubuntu isn't a supported operating system, but I am fairly positive I had an earlier version of Ubuntu on my R710 at home. I would recommend you crate a RAID volume, and then try again. Setting a drive to a global hotspare with no raid config just sets the drive into a state where it will do nothing and be unavailable to anything, as a hotspare can only act in support of a RAID volume. I would create whatever RAID level you want, then try the install again. The PERC doesn't act like an HBA, in that the hard drives would get passed straight through. You have to make a virtual disk first, then the OS should see storage. If not, then the version of Ubuntu you have is missing a driver. However, with Ubuntu not being supported, there isn't a driver for it on the Dell website. </s>
<s>[INST] In my old production environment, I have 2 PE R640 and a Dell PS4100 connected to a PowerConnect 6224 using the iSCSI protocol. Now, I bought two new Dell EMC S3124 and a Dell EMC SCv3020 to improve my production environment, and I'll continue using iSCSI protocol. My new switch configuration is in the following link: [URL] I don't connected all interfaces of the hosts as it is in the image, because I don't execute the migration to my new environment. In this moment, just four SCv3020 interface per controller and two R640 interfaces are connected. My switches are stacked. I'm using the VMware vSphere 6.5 as my hypervisor. If you guys could help me, here are my doubts: [/INST] Hello, Are all your volumes on VMFS Datastores? There are three ways to migrate data from PS to SC. Not in any order: 1.) Thin Import 2.) XPR Replication (Cross Platform Replication The PS Storage needs to be on 10.0.x firmware) 3.) Storage vMotion. #3 is one that can be done live. The other two would require some downtime. Basically you just need an ESXi server that can see both the old and new storage. Then you can migrate VMs to the new SAN. I suspect the new storage is configured for 10GbE so this should be pretty easy to do. You don't need to interlink the old PS iSCSI SAN and the new iSCSI SAN for SC. Option 1 and 2 would require access from the PS iSCSI network to the new SC iSCSI network. You can also open a support case and they will help you with this as well. Here are some links with info on PS and SC storage together [URL] [URL] Regards, Don </s>
<s>[INST] Are there any updateed stencils of MX-7000 series ? [/INST] Hello, The Visio stencils aren't utilities we keep up with. That having been said, I did find something that looks like it may be what you need. That's the description for the Dell-ModularInfrastructure file. You might check it out. [URL] </s>
<s>[INST] Hi everyone, I need some help with the situation which I am not very familiar with. I have a DELL EMC R830 in production and for the moment I am using only two HDD in Raid 1, now I wanted to add 4 more HDD because I am running out of space but not sure if I can do that without loosing my data and my Windows 2012 R2 OS which is running with couple VMs on Hyper V. Any advice is highly appreciated. [/INST] Hello, You can increase your storage without issue. The easiest thing to do would be to insert the drives into the server, then you would need to create a virtual disk using either OpenManage Server Administrator, or the iDRAC. Once the virtual disk is created, you can then use Windows' Disk Manager to partition it and lay out a file system for use. If you are unfamiliar with creating virtual disks in the iDRAC or OpenManage, there are numerous videos on YouTube showing it, several are from the Dell Tech Center channel. They should be of help. </s>
<s>[INST] Hi All, We have hosts to be migrated from VNX to Unity. One host has 76 luns. I plan to put them in one CG instead of creating migration session one lun each. However, Unity only support CG up to 50. How do I migrate this host using the block import feature? Thanks. [/INST] you need to stay within the limits or it wont work </s>
<s>[INST] Hi Team, can anyone help me to my T410 server is not booting. While booting it showing the [IMAGE]warning message. attached the screenshot. Regards, Madhu [/INST] Hello The error message is states what the issue is. The BIOS is set to the boot mode of legacy/BIOS. Whatever operating system you are trying to boot from is configured to boot from UEFI mode. There is an option in the system setup/BIOS called "Boot Mode" or something similar to that. The manual on the system support page may have additional information about BIOS settings. [URL] Thanks </s>
<s>[INST] Hello I have EqualLogic PS 6100 controller and did a reset using cli. It wiped everything and started setup. However when I go through the setup name, IP, etc first it says looks like it was running before do you want to restart? I said yes and it is cycling with error can't bring eth0 on line. I 100% sure it is on the network, swaped all cables and tested on other switch, there is no light on eth0 (management port) once you plug the cable. This is kinda urgent and I need a solution if anyone knows. Thanks [/INST] Hello, By default the Management port (ETH4 here) is NOT enabled. Put a cable on that if you want to use the out-of-band dedicated management feature. Which has to be enabled later. The other interfaces should be connected, but the default one to start is ETH0. If not link is detected when you configure it, the setup will fail. Once you have it setup, and can access the GUI, you can enable the Management Feature. You don't just assign that port a different IP. You must enable the Dedicated Management Feature and confgure the IPs for management there. Otherwise the Discovery Address is used for both iSCSI session logins and management. Regards, Don </s>
<s>[INST] Hi Dell Community, I downloaded the old and latest version of my dell r730xd bios version. When I try to upload the file from my idrac settings > Update and Rollback > Update, Choose File, Upload > Once completed the status "Unable to complete the firmware update operation because the specified firmware image is not in the target system inventory". What does status means? Even I try the lower version up to the latest but the same status result. Cheer! \m/ [/INST] I've seen this happen in two circumstances. The first being in the case of a large upgrade in firmware. The second is if the iDRAC is lagging behind the BIOS target version. If you've tried multiple BIOS updates, I would try flashing the iDRAC. The current iDRAC version is 2.63.60.61. What version is the server running? Also, do you have a link to the file you are using to try to update? </s>
<s>[INST] Hi all, I am just wondering if the racadm racreset hard command do the same thing as if I will do it via gui Overview ? Server under Quick Launch Tasks; is ¡®Reset idrac'. Thank you [/INST] Nintrix, Both would do the same thing of restarting the iDrac, now if your goal is to in fact reset the iDrac to defaults that would be the racadm racresetcfg command. </s>
<s>[INST] I have been unable to find the system test for online proctoring. Is this not an option for the DellEMC cert exams? [/INST] Hello Sam, We're offering "Online Proctoring Dell Technologies Proven Exams" Please check link below. [URL] and please let us know if you have any questions. Thank you for your post Sam. Naomi </s>
<s>[INST] Trying to upload new iDrac 2.63.60.62 to a M620 Gen12 through CMC 6.1 but it's taking too long to complete .. it has past 30min and only 10% upload... Anyone having this same issue? I'm using 6.1 for at least 6 months, and this is the first time updating iDrac firmwares that causes this issue..when I updated to 2.60.60.60 did not had this issue, this is a iDrac package problem or CMC issue with this new firmware? [/INST] the CMC 6.20 fixes the issue, but just to let you know, the slow problem only happened in 6.1 using idrac firmwares with lifecycle controller, with other firmwares, like CMC, SAS RAID or Ethernet Controllers, no problems!! </s>
<s>[INST] Hello: I send you this message because a few days ago, our Dell PowerEdge 2970 server that is out of warranty has stopped working and, when we try to start it, always offers the following information:PCIe Training Error: Integrated Storage SlotSystem halted! We are interested in getting it back on track, Does Dell have a repair service for out-of-warranty servers? Otherwise, can someone tell us what could be failing and, if possible, what electronic card should we replace to get it going again? Thank you very much and best regards.[IMAGE] [/INST] I could give you a couple part numbers to look for, but Dell hasn't sold 73gb drives in several years, so I wouldn't be able to point you in the right direction on where to find them. RW675RW548 (current hard drives part number) </s>
<s>[INST] Hi, I have configured my VRTX with a trunk on 2 of the 10Gb connections and a trunk on the 1Gb connections. I configured it so that 2 vLANs were for the 10Gb trunk and 1 vLAN for the 1Gb trunk. I am using VMware ESXi and I have configured 2 switches, switch 1 goes to the 2 vLANS on the 10Gb trunk and switch 2 goes to the vLAN on the 1Gb trunk. I then created 2 test VMs one pointing to the 10Gb trunk and one pointing to the 1Gb trunk. The VM for the 10Gb trunk is working fine but the 1Gb trunk is not giving me anything. Any ideas would be welcome as I am out of them. [/INST] We have fixed this, all we did was apply the same configuration but from the command line! Now it is working fine, go figure. </s>
<s>[INST] Hi, I recently bought a used dell R610 and used the iso tu successfully update everything BUT the BIOS. The installer program works fine (launched from the contos ISO produced by drm) but on reboot I get a "BIOS update failed" message. I understand from other threads It might be caused by how old the current BIOS is. Is there any way to get an intermediate version that might work? The oldest available is 6.10 and fails just like 6.6.0 Thanks Edit: verion info 2.0.11 [/INST] Aste88, If you follow this link it will show the previous versions back to 1.0.4. What I HIGHLY recommend you do is walk it up to current, with the iDrac if you haven't already, as you don't want them to get too far apart. I would suggest downloading and running the ones marked Urgent, as well as not jumping more than like 3 updates at a time. </s>
<s>[INST] Hi guys... I have recently bought an old PowerEdge 2850 and she is now running beautifully.... (after a lot of TLC I must add)... BUT... The one last issue I have is that the screen resolution on my monitor is not correct. The "Display Adapter" says - Standard VGA Graphics Adapter (???) The Monitor is - Samsung SyncMaster BX3021 (driver is installed) The Chipset says - ATI Radeon VE The OS is - Windows Server 2008 R2 I tried to download an ATI Radeon driver but it was obviously the incorrect one as all my RAID drives FAILED - I think that was because it was for Server 2008 and not server 2008r2 - so I'm a bit nervous to try another Display Adapter driver because I had to re-create the RAID drives and install everything AGAIN.....etc. Am I stuck with the - "Standard VGA Graphics Adapter" - or what? Surely the ATI Radeon should be giving me better graphics (or at least be able to handle the screen resolution of the Samsung monitor).... Sorry, I am not very clued up w.r.t graphics cards and old servers.... I'd appreciate it if someone could point me in the right direction here.... Thanx Mike [/INST] Hello The integrated graphics on servers is very limited. I suspect the max resolution on the 2850 is around 800x600, maybe 1024x768. This information is probably listed in the manual on the system support page. [URL] Thanks </s>
<s>[INST] I have a PowerEdge T430 with 8x Samsung 830 DCT 960GB on a Perc H700 controller and Windows Server 2016 Datacenter in a RAID 0 setup (this is for testing).The single drives are 500+ MB/s read and write on the PERC H700 as a non-RAID disk. 6 of them in RAID 0 was capped at ~1600 MB/s Read/Write. Adding 2 more drives to the RAID 0 produced no increase in speed. So 8 drive RAID 0 is also ~1600 MB/s. That doesn't seem right to me as I'd expect to increase speed as I add drives. The initial speed of 1600 for 6 drives seems around half of what it should be (shouldn't 6x 500MB/s drives be around 3k MB/s?) I'm not sure where the bottleneck is. Any insight is appreciated. [/INST] UPDATE and SOLUTION: After a few days of wondering what's going on and subsequently posting my question to the community, I found the problem. To make room for other cards, I moved the PERC H730 from the full length PCIe slot in position 4 to the top slot in position 1. I didn't realize those slots changed bandwidth quite that drastically. After moving the PERC H730 back to PCIe slot 4, I'm getting 4000 MB/s read and 3700 MB/s write which is what I'd expect for 8x 500MB/s drives in a RAID 0. The PCIe slot the RAID controller was in was the bottleneck. </s>
<s>[INST] whats the equivalent of server_cifs -o audit from VNX to unity ? Why ? /metrics/value/rt -path sp.*.cifs.global.usage.currentOpenFiles show on unity gives the open file count, but does not have the grainularity of listing Knowing this info helps debug issues ? similarly for NFS [/INST] see svc_cifssupport -audit I dont think there is a similar command for NFSwith NFSv3 there is no open/close in the protocol so the servers isnt aware of which files the client has openedsimilar for users - NFS shares get mounted by root If you want to know which clients have NFS shares mounted then you can use showmount from a client </s>
<s>[INST] Hello everybody, I continue to ask questions because this case is new for me. I have a switch PowerConnect 7048P and a server PowerEdge R710 (DEBIAN 9.8). On one hand, intn the switch, I have done an aggregation link (number 40) with LACP between the port 13 and 14. [IMAGE][IMAGE][IMAGE] And the other hand, I made the server ports configuration like this : [IMAGE] When I check the bonding interface with the ifconfig command, everything looks "OK" : [IMAGE] But when I try to ping the server from the switch, this is failed. I[IMAGE] When I try to ping the server virtual lan interface from the server, I can't but when I try to ping another virtual lan interface, I have the message "packets filtered" : [IMAGE][IMAGE] For me, it looks like something blocked from this server but I don't know why. I can specify another server is configured on the same VLAN and from it I can ping all of the virtual lan interfaces... if someone have an idea, I will be interested. Best regards. SARL TSF [/INST] Hi, I have found the solution of my problem. It was about the modules NetworkManager and ifenslave on Debian. Maybe they have some bugs inside them about LACP. Finally I have used the systemd-networkd module for the network configuration. For using it you need to stop with the /etc/network/interfaces file. All of the new configuration files need to be inside the directory /etc/systemd/network/. I show you all of my configuration files for my cases : [IMAGE][IMAGE][IMAGE][IMAGE][IMAGE][IMAGE] I think this solution is available for all kind of PowerEdge Rxxx version. I hope this will help someelse. Best regards. </s>
<s>[INST] Various components on the DP4400 will fail to be to ping each other or be able to ping the local gateway, This can also impact the ability to ping interfaces from the production network. This Knowledge article can help in the above issue, Link : [URL] [/INST] Replying to mark TOTAL OF ALL PREVIOUS POSTS IN THIS DISCUSSION as the SOLUTION. But please continue to post any questions/comments. </s>
<s>[INST] One of the reasons why a deployment could fail is NTP issue. This KB serves as a guide to prevent a known DP4400 failure during deployment. These actions need to be taken BEFORE committing the DP4400 deployment from the Appliance Configuration Manager (ACM). This KB should be followed BEFORE deploying the DP4400. Link : [URL] [/INST] Replying to mark TOTAL OF ALL PREVIOUS POSTS IN THIS DISCUSSION as the SOLUTION. But please continue to post any questions/comments. </s>
<s>[INST] A lot of customer find difficulties in finding the service tag for any system as Service Tag details are not often readily provided or available. Dell Service delivery requires the Dell Service Tag in order to facilitate Support, Parts & Dispatch operations. use this guide to retrieve the required Service Tag. Applies to any systems based on Dell PowerEdge server platforms.(a.k.a Mixed IP) for example DD3300 and DP4400. Link : [URL] [/INST] In addition to above, here is another good reference to find Service Tag (Asset Tag), Serial Number etc for IDPA models: [URL] We welcome questions and contributions from all. If you found this useful please give KUDOS to help others find the information also. thanks </s>
<s>[INST] Hello, we need to recover only some files using wildcard * from a shell script.We saved all files under directory "/some_path/dir_name" and now we need to recover only some files with name beginning with aaa from that directory via a shell script. It seems to me that with networker is not possible to use wildcards in recover. I tried: /usr/bin/recover -a -t -d /some_path/dir_name/aaa* and it returns: 67847:recover: Failed to recover files: Nothing to recover when I set the exact filename not using wildcard, it works. It is not possible to use wildcards with recover command with no interactive browsing in networker ? Thanks Andrea [/INST] The issue is that you are running linux. Here you can in fact create files and directories which contain a '*' in their name. In case of your task I see two possibilities: - run nsrinfo on that savetime first and filter the exact path names to recover. Then add these names to a recover list. - restore the whole save set to temp directory and get your files from here. </s>
<s>[INST] Hello, it's me again with a question, We have a Dell PowerEdge R510 running as a NAS server. it's running Windows Server 2016. We noticed there is a red light blinking under the power button. I know there is something wrong with it, I just can't figure out what. All disks in it are giving me green lights. the Power modules also have green lights. How can I find out what is wrong with this server? Thanks in advance, Kind regards, Bjorn [/INST] The easiest thing to do would be to log into the iDRAC and check the SEL, if you can. If the iDRAC isn't an option, then the next tool you could use to check would be OpenManage Server Administrator. You can install that and then view the system log. OMSA 9.3: [URL] </s>
<s>[INST] Customer Env: K8S 1.13.3 K8S host CentOS Linux 7.4 VxFlex 3.0.769 *********************************************** 3SDS/MDM£ºData1:192.168.1.2-4Data2:192.168.2.2-4App£º10.8.192.89-91 Gateway 10.8.192.89Primary MDM 10.8.192.90 System ID MDPM IPs7a5ada7d5a833e0f 10.8.192.89 10.8.192.90 **************************************************K8S£º kube-master 10.8.192.27 kube-m1 10.8.192.28 kube-m2 10.8.192.40 kube-m3 kube-worker 10.8.192.39/41/44 ************************************************** As follow the below video and product guide: [URL]#enable-csi-in-k8s-cluster **************************************************************************************** [root[NAME]-m1 helm]# sh install.vxflexosKubernetes version v1.13.3Kubernetes master nodes: 10.8.192.27 10.8.192.28 10.8.192.40Kubernetes minion nodes: 10.8.192.41 10.8.192.39 10.8.192.44Verifying the SDC installation.Retrieved 1 mdm(s)MDM-ID 7a5ada7d5a833e0f SDC ID e71b7b7500000004 INSTALLATION ID 0f7a6e0e2eb88757 IPs [0]-10.8.192.89 [1]-10.8.192.90Retrieved 1 mdm(s)MDM-ID 7a5ada7d5a833e0f SDC ID e71ba28500000007 INSTALLATION ID 0f7a6e0e2eb88757 IPs [0]-10.8.192.89 [1]-10.8.192.90Retrieved 1 mdm(s)MDM-ID 7a5ada7d5a833e0f SDC ID e71ba28600000008 INSTALLATION ID 0f7a6e0e2eb88757 IPs [0]-10.8.192.89 [1]-10.8.192.90Verifying the feature gates.node 10.8.192.27 proc /usr/bin/kubelet gate VolumeSnapshotDataSource=true failednode 10.8.192.27 proc /usr/bin/kubelet gate KubeletPluginsWatcher=true failednode 10.8.192.27 proc /usr/bin/kubelet gate CSINodeInfo=true failednode 10.8.192.27 proc /usr/bin/kubelet gate CSIDriverRegistry=true failednode 10.8.192.27 proc /usr/bin/kubelet gate BlockVolume=true failednode 10.8.192.27 proc /usr/bin/kubelet gate CSIBlockVolume=true failednode 10.8.192.28 proc /usr/bin/kubelet gate VolumeSnapshotDataSource=true failednode 10.8.192.28 proc /usr/bin/kubelet gate KubeletPluginsWatcher=true failednode 10.8.192.28 proc /usr/bin/kubelet gate CSINodeInfo=true failednode 10.8.192.28 proc /usr/bin/kubelet gate CSIDriverRegistry=true failednode 10.8.192.28 proc /usr/bin/kubelet gate BlockVolume=true failednode 10.8.192.28 proc /usr/bin/kubelet gate CSIBlockVolume=true failednode 10.8.192.40 proc /usr/bin/kubelet gate VolumeSnapshotDataSource=true failednode 10.8.192.40 proc /usr/bin/kubelet gate KubeletPluginsWatcher=true failednode 10.8.192.40 proc /usr/bin/kubelet gate CSINodeInfo=true failednode 10.8.192.40 proc /usr/bin/kubelet gate CSIDriverRegistry=true failednode 10.8.192.40 proc /usr/bin/kubelet gate BlockVolume=true failednode 10.8.192.40 proc /usr/bin/kubelet gate CSIBlockVolume=true failednode 10.8.192.41 proc /usr/bin/kubelet gate VolumeSnapshotDataSource=true failednode 10.8.192.41 proc /usr/bin/kubelet gate KubeletPluginsWatcher=true failednode 10.8.192.41 proc /usr/bin/kubelet gate CSINodeInfo=true failednode 10.8.192.41 proc /usr/bin/kubelet gate CSIDriverRegistry=true failednode 10.8.192.41 proc /usr/bin/kubelet gate BlockVolume=true failednode 10.8.192.41 proc /usr/bin/kubelet gate CSIBlockVolume=true failednode 10.8.192.39 proc /usr/bin/kubelet gate VolumeSnapshotDataSource=true failednode 10.8.192.39 proc /usr/bin/kubelet gate KubeletPluginsWatcher=true failednode 10.8.192.39 proc /usr/bin/kubelet gate CSINodeInfo=true failednode 10.8.192.39 proc /usr/bin/kubelet gate CSIDriverRegistry=true failednode 10.8.192.39 proc /usr/bin/kubelet gate BlockVolume=true failednode 10.8.192.39 proc /usr/bin/kubelet gate CSIBlockVolume=true failednode 10.8.192.44 proc /usr/bin/kubelet gate VolumeSnapshotDataSource=true failednode 10.8.192.44 proc /usr/bin/kubelet gate KubeletPluginsWatcher=true failednode 10.8.192.44 proc /usr/bin/kubelet gate CSINodeInfo=true failednode 10.8.192.44 proc /usr/bin/kubelet gate CSIDriverRegistry=true failednode 10.8.192.44 proc /usr/bin/kubelet gate BlockVolume=true failednode 10.8.192.44 proc /usr/bin/kubelet gate CSIBlockVolume=true failedfail: 1*******************************************************************************Warning: Kubernetes --feature-gates not correctly configured... it may not work*******************************************************************************NAME: vxflexosLAST DEPLOYED: Wed Jun 5 13:48:46 2019NAMESPACE: vxflexosSTATUS: DEPLOYED RESOURCES:==> v1/Pod(related)NAME READY STATUS RESTARTS AGEvxflexos-node-55crv 0/2 ContainerCreating 0 0svxflexos-node-5dfg6 0/2 ContainerCreating 0 0svxflexos-node-qpfzj 0/2 ContainerCreating 0 0svxflexos-controller-0 0/4 ContainerCreating 0 0s ==> v1/StorageClassNAME PROVISIONER AGEvxflexos-xfs csi-vxflexos 1svxflexos (default) csi-vxflexos 1s ==> v1/ServiceAccountNAME SECRETS AGEvxflexos-controller 1 1svxflexos-node 1 1s ==> v1/ClusterRoleNAME AGEvxflexos-controller 1svxflexos-node 1s ==> v1/ClusterRoleBindingNAME AGEvxflexos-controller 0svxflexos-node 0s ==> v1beta2/DaemonSetNAME DESIRED CURRENT READY UP-TO-DATE AVAILABLE NODE SELECTOR AGEvxflexos-node 3 3 0 3 0 0s ==> v1beta1/StatefulSetNAME DESIRED CURRENT AGEvxflexos-controller 1 1 0s ==> v1alpha1/CSIDriverNAME AGEvxflexos 0s NAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ErrImagePull 0 10svxflexos-node-55crv 0/2 ErrImagePull 0 10svxflexos-node-5dfg6 0/2 ImagePullBackOff 0 10svxflexos-node-qpfzj 0/2 ErrImagePull 0 10sNAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ErrImagePull 0 15svxflexos-node-55crv 0/2 ErrImagePull 0 15svxflexos-node-5dfg6 0/2 ImagePullBackOff 0 15svxflexos-node-qpfzj 0/2 ErrImagePull 0 15sNAME READY STATUS RESTARTS AGEvxflexos-controller-0 0/4 ImagePullBackOff 0 20svxflexos-node-55crv 0/2 ImagePullBackOff 0 20svxflexos-node-5dfg6 0/2 ImagePullBackOff 0 20svxflexos-node-qpfzj 0/2 ImagePullBackOff 0 20sCSIDrivers:NAME AGEvxflexos 20sCSINodeInfos:NAME AGEkube-n1 1dkube-n2 1dkube-n3 1dStorageClasses:NAME PROVISIONER AGEvxflexos (default) csi-vxflexos 22svxflexos-xfs csi-vxflexos 22sNo resources found.installing volumesnapshotclassvolumesnapshotclass.snapshot.storage.k8s.io/vxflexos-snapclass createdVolumeSnapshotClasses:NAME AGEvxflexos-snapclass 1s [/INST] I just wanted to follow up on ZhangFan4's question. He reports that he was able to work around his issues. The user reports that he does have CentOS 7.4. His paths for the feature gates and Docker service were different than that in the docs. He was able to find the files in different locations and modify them appropriately. He did modify the verify.kubernetes script MINION_PROCS to point to his location. He also installed the VxFlex OS Storage Data Client (SDC) on the Master. I also had issues with setting up the feature gates. I found that copy and paste from the Prod Guide did not work as expected. To help I ran the yaml through a yaml checker to assist with spacing, alignment, and dashes. I also ran Flo_csl's recommended command to check the feature gates. Mine now show enabled: systemctl status kubelet.service -l a kubelet.service - kubelet: The Kubernetes Node Agent Loaded: loaded (/usr/lib/systemd/system/kubelet.service; enabled; vendor preset: disabled)Drop-In: /usr/lib/systemd/system/kubelet.service.daa10-kubeadm.confActive: active (running) since Thu 2019-06-27 16:48:23 EDT; 4 days agoDocs: [URL] PID: 7838 (kubelet)Tasks: 30Memory: 143.9MCGroup: /system.slice/kubelet.serviceaa7838 /usr/bin/kubelet --bootstrap-kubeconfig=/etc/kubernetes/bootstrap-kubelet.conf --kubeconfig=/etc/kubernetes/kubelet.conf --allow-privileged=true --feature-gates=VolumeSnapshotDataSource=true,KubeletPluginsWatcher=true,CSINodeInfo=true,CSIDriverRegistry=true,BlockVolume=true,CSIBlockVolume=true--config=/var/lib/kubelet/config.yaml --cgroup-driver=systemd --network-plugin=cni --pod-infra-container-image=k8s.gcr.io/pause:3.1 </s>