text
stringlengths
29
274k
<s>[INST] I have avamar windows client with 5 million small files that has backup issue. It happens in last couple days. I modified filecachemax=- (from 8 to 6) , hashcachemax=- (from 16 to 12) but backup is still running slow (22h for 836 GB) . Anyone recommends on it ? Thank you. Tom [/INST] after worked around and called to support. Backup is running well. </s>
<s>[INST] I've just upgraded one of our N3000 stacks to firmware version 6.5.4.10 (from 6.3.1.13) and boot code U-Boot SPL 2012.1--00079-g20827d2 (May 22 2017 - 16:58:14). Our current CPLD version is 13. When I try to update the CPLD version, using the command update cpld, I get an Invalid input detected at '^' marker message, with the ^ marker on the c of cpld? I followed up upgrade instructions, step-by-step? Can anybody offer any advice? Many thanks [/INST] It looks like each switch in the stack separately. </s>
<s>[INST] Hi Everyone Please tell me about the "Low Space Behavior" job added from Isilon OneFS8.2. [URL] "In situations where the job engine sees the available capacity on one or more disk pools fall below a low space threshold, it engages low space mode. This enables space-saving jobs to run and reclaim space before the job engine or even the cluster become unusable.When the job engine is in low-space mode new jobs will not be started, and any jobs that are not space-saving will be paused.Once free space returns above the low-space threshold, jobs that have been paused for space are resumed." *page24 There is such a description in the above white paper. Is there any reference material that mentions the threshold of this Low Space Mode?Can this threshold be changed? [/INST] Hello takmiyagi, Low space threshold is normally happening when the available capacity falls below 5%. You don¡¯t want to change this as doing so may cause issues with your system. Please let us know if you have any other questions. </s>
<s>[INST] Hello, being in need of storage amount extension for an PE R520 server, but in doubt of certain hardware pieces compatibility. May I please ask here to clarify whether or not the following devices will be compatible and working together properly? Having PowerEdge R520, BIOS v. 2.7.0, with PERC H710 Mini with 21.3.5-0002 firmware. Will it work with these DELL HDDs: Many thanks in advance! [/INST] iag042016, I researched the drives you inquired about, and from what I see, only #2 is actually showing a supported on the R520 platform. Hope this helps. </s>
<s>[INST] Is there a way to tell which revision my Dell R410 mother board is, preferably without iDRAC or OMSA (I have neither). I have a service tag number. Also, is there any clarifying documentation on which CPUs are available with which revisions? The documentation says that all r410s support 5600s, but it then goes on to only cite 5500 CPUs. I am trying to get a hexacore with HT for my r410, but I am not sure if it is compatible or not. [/INST] I was able to find the information being referenced. With the hardware you have, you'll be limited to the 5500 series. Based on the information available on Intel's website, it does not appear that you will be able to use a hexacore processor. Here's the relevant page on Intel's site: [URL] I sorted based on core count, but didn't see an option in the series. </s>
<s>[INST] Hello we are just starting to use Configuration Compliance templates on a number of servers we have. however can some one tell me how to recheck a server once a template has been applied to see if any changes have occurred? i have manualy changed a number of BIOS settings on one of the servers to see if and when Open mange flags up the issue but at the moment it is saying the server is fine. thanks in advance [/INST] HI Josh thanks for the reply, however no matter what report i run it still dose not start a re-check. however i have seen that at midnight each night a re-check is started but this is hit and miss. i have also refreshed the inventory, the status as well as on-boarding but again fails to pick up any changes i have made. i have been looking through the user manuals but i can't find anything on how often communication/heartbeats between the OME appliance and discovered servers is initiated thanks </s>
<s>[INST] Hello, I¡¯ve just purchased Poweredge T30 server. Inserted NVME and 4 SATA drives and installed ESXI 6.7 on SSD. Now I want to passthrough my SATA drives to VM, but unfortunately ESXI doesn¡¯t allow me to passthrough SATA controller (I even don¡¯t see it in the devices list). I switched SATA to AHCI mode in BIOS, but still no luck. All SATA drives are operational, double checked them. BIOS sees them as well as ESXI does. Am I missing something? Is there any limitations in embedded SATA controller? Should I buy external SATA controller which supports passthrough? If yes, what kind of model you¡¯d suggest, gents? [/INST] SOLVED: If anyone meet the same issue as mine do the following: add the line below into your /etc/vmware/passthru.map file: # INTEL SUNRISE AHCI PASSTHRU8086 a102 d3d0 false Save file and restart ESXi. This solution fully works on ESXi 6.7U2 on Poweredge T30. </s>
<s>[INST] Greetings!I'm planning to buy a T340 server, 210-AQSN-3.But it comes with one 1.2 TB SAS drive only.I want to add one more, and the only model our local distributor offers is Dell 1.2 TB (400-AEFW).Is to compatible with T340?Can't find any list of supported HDDs for T340.Thank you. [/INST] T140 - 1TB SATA drives Part #'s HNWHH K4M5W MM8P9 W0VNC t340 - 1.2TB SAS Drives Part #'s 01M0D 0KV02 3K30N DMP3R FR6W6 G2G54 V2KWT </s>
<s>[INST] Hello, the question have been raised some years ago ([URL] but left unanswered. So what a mysterious thing about CPLD (complex programmable logic device) within Dell PowerEdge servers, one can't find on the Dell site? What is the fucntion of CPLD there? Is it necessary to update its firmware (if applicable) while updating firmwares for other internal server devices? As far as I've found out, one should NOT touch the CPLD until it's REALLY needed. So I do not intend to mess with it, especially while don't uderstand the base things about the stuff. Worthwhile answers are appreciated. Thanks! [/INST] Hi, We only provide updates for it if necessary, It allows for changes to system board functions beyond what the BIOS does. </s>
<s>[INST] i added a physical hdd to my server, can i expand my RAID 5 configuration using OMSA without loosing any data on the HDDS that were already there? [/INST] While I would always suggest having a complete backup of the data prior to doing anything in the raid, Yes that is correct the H730 does support Online Capacity Expansion and shouldnt affect the data while performing such. </s>
<s>[INST] Hello, I just bought a R410 that is configured with Perc 6i/Backplane. I have a bunch of 3 and 4TB drives that I want to use in this server. I understand that the Perc 6i does not "support" drives >2TB. I do not care/want to use RAID. I have been reading about the Dell P459G cable and converting to cabled drives. Would my drives be seen as 3 and 4TB connected directly to the motherboard, or is there a limitation there as well? To use this cable, do I need to remove the Perc expansion card and the backplane? [/INST] NerotiX, You can run the drives to the motherboard, with the cable you referenced, but would need to enable the SATA ports in the BIOS. Also, if you install an H700 in the server, it is not limited to the same physical disk limitations the Perc 6/i is. Hope this helps. </s>
<s>[INST] Hi I have acquired 2 PowerSwitch S5248F to implement stack But they come with the OS10, I understand this version does not support Stacking. Is it possible to downgrade the OS10 to the OS9 version? And if possible, is there an official Dell guide to do so? Thanks Martin [/INST] I'm fairly certain that is a OS10 only switch. Is there something you need with stacking that VLT will not work for? </s>
<s>[INST] When I select [URL] I keep arriving on [URL] And since I don't have any registered products nor am I a partner, I can't seem to get past that page. [/INST] Hello LucD22, you need to have an EMC account in order to access the page. Here is a knowledge base article that states that as well. [URL] You will need to create an account on [URL] Once that is done then use the [URL] & it should bring you to the page. Please let us know if you have any other questions. </s>
<s>[INST] Hi, I have installed a Powervault TL1000 on an R540 server with Windows Server 2019. I can see the tape drive in device, but when I have installed "Veeam Backup and Restore" only the drive appears and not the tape loader so there are no slots appearing and I have to manually load the tape into the drive from whichever slot. I was told on the Veeam forums that I needed to have the loader in device manager, which I don't see anywhere but I have loaded all the drivers from the support site so I'm not sure why it doesn't appear. I have the drive connected to the HBA 12Gbps SAS external connector port. 1. Should the Tape Loader appear in device manager? 2. Under what area will it appear? 3. Currently the drive is just listed as "IBM Ultrium 8 HH 3580 TAPE DRIVE" is this correct? [/INST] Hello TyreeIT, Here is the link to the user¡¯s guide for your TL1000, & if you look on page 34 you can see where you need to make sure your TL1000 is set to random. [URL] Also, when you installed the drivers did you have windows install the driver or did you use install_nonexclusive.exe file? If you did not use the install_nonexclusive.exe then I would run that file and it will install the drivers for the medium changer/ autoloader. Please let us know if you have any other questions. </s>
<s>[INST] I'm trying to provision the iDrac via teh Redfish API. I'm able to configure raid arrays for the following raid levels (0,1,5 and 50). I want to create a raid 6 array however and this doesn't seem possible. Is that correct or am I'm missing something? [/INST] Redfish volume schema currently only support RAID 0,1, 5, 10 and 50 (Refer "VolumeType" section on page 545 of below link). As redfish schema only support these volumes iDRAC will also allow to create only these RAID levels using redfish. You can use Racadm or WSMAN interfaces to create RAID 6 or 60. [URL] </s>
<s>[INST] I've searched and not found this exact scenario so apologies if this is covered elsewhere. I have two Dell PowerEdge R710s, one with 8 x 4GB DIMMs (32GB total) and one with 8 x 2GB DIMMS (16GB Total). They are operating on Advanced ECC obviously on a Dual Xeon config. I think I know the answer to this but it's early in the morning and I need a sanity check.... Is there any way I can configure these servers with 24GB in each, for ECC and the processors to be happy without buying more memory? [IMAGE][IMAGE] I'm off for some coffee... [/INST] Ok - Please ignore.. I realized I could put: R710 - 1 R710 - 2 But I also decided it was far easier to move VMs to servers with more RAM. </s>
<s>[INST] Hello, I think I do really not understand some net concepts. I am trying to configure a N4032 switch, I made a soft-reset from a previous configuration. Now I can access via minicom and config it, but I am not able to access via HTTP and I assume it is because I am mixing some base concepts. this is a scheme of what I'm want to do: |----- iDRAC ----- ¢¯ ?||--------------------| interface em1 --- public IP (assigned)| LOGIN NODE ||--------------------| interface em2 --- 10.1.1.1/24 em2:0 - 192.168.0.1/24 ---| ||--------------------| port_1 < --- eth --- > em2 --------|| SWITCH ||--------------------| I though i needed a VLAN for the OOB like 192.168.0/24 segment, then assign an IP for each device and connect them via Switch but now, I think this is not the way ... I don't know how to configure the switch for access via HTTP, I tryied this link: [URL] but since I set it wrong it says that VLAN1 and OOB cannot be at the same segment. I wanted 192.168.0.X be the "OOB" net and I assigned 192.168.0.2 to the switch but I cannot access to the HTTP client. I just want to have a 10.1.1.0/24 segment for service and know how OOB works in order to connect to iDracs and the switch's client. thanks all, Sergio [/INST] Login host ip a s (em2) 3: em2: mtu 1500 qdisc mq state UP group default qlen 1000 link/ether f0:1f:af:ce:fe:89 brd ff:ff:ff:ff:ff:ff inet 10.1.1.1/24 brd 10.1.1.255 scope global em2 valid_lft forever preferred_lft forever inet 192.168.0.1/24 brd 192.168.0.255 scope global em2 valid_lft forever preferred_lft forever inet6 fe80::f21f:afff:fece:fe89/64 scope link valid_lft forever preferred_lft forever </s>
<s>[INST] I have a PowerVault TL 1000 and I was configuring the snmp monitoring with zabbix. I found that, when I query a OID with snmpget, I recive a error. But, if I query the same OID with snmpwalk it's work. Why?[IMAGE] [/INST] Hi, This has some information on the commands, [URL] </s>
<s>[INST] I am not able to figure out how much physical space a specific LUN is taking in XtremIO. Their is column Logical used VSG, If I am correct this is the data size which it was supposed to take before Dedup and compression. Can someone please help me how to find the physical space or the utilized space of LUN in XMX version 6. [/INST] Hello Ashyyyy, It would be best for you to call into support so that we can look at your system and show you how much spaced is being used. Please let us know if you have any other questions. </s>
<s>[INST] R610 running Windows Server 2012 R2firmware updated to V6.6I'm able to login to the iDARC using its web address and it shows as Enterprise.Tried to update iDRAC Enterprise using ESM_Firmware_KPCCC_WN32_2.92_A00.EXE (Dell iDRAC Monolithic Release 2.92, A00iDRAC6 Firmware Upgrade problem - "Device iDRAC6, Application, iDRAC6, failed to access Virtual USB device".Investigating shows USB mass storage not able to start with "Insufficient system resources exist to complete the API". Below is the racadm getsysinfo output. How do I get the iDRAC to current revision? racadm getsysinfo RAC Information:RAC Date/Time = Sun Feb 02 22:26:30 2020Firmware Version = 1.70Firmware Build = 21Last Firmware Update = 04/07/2011 20:28:43Hardware Version = 0.01MAC Address = 14:fe:b5:d2:94:7a Common settings:Register DNS RAC Name = 0DNS RAC Name = idrac-C2G5FP1Current DNS Domain =Domain Name from DHCP = 0 IPv4 settings:Enabled = 1Current IP Address = 192.168.1.230Current IP Gateway = 192.168.1.1Current IP Netmask = 255.255.255.0DHCP Enabled = 0Current DNS Server 1 = 0.0.0.0Current DNS Server 2 = 0.0.0.0DNS Servers from DHCP = 0 IPv6 settings:Enabled = 0Current IP Address 1 = ::Current IP Gateway = ::Autoconfig = 1Link Local IP Address = ::Current IP Address 2 = ::Current IP Address 3 = ::Current IP Address 4 = ::Current IP Address 5 = ::Current IP Address 6 = ::Current IP Address 7 = ::Current IP Address 8 = ::Current IP Address 9 = ::Current IP Address 10 = ::Current IP Address 11 = ::Current IP Address 12 = ::Current IP Address 13 = ::Current IP Address 14 = ::Current IP Address 15 = ::DNS Servers from DHCPv6 = 0Current DNS Server 1 = ::Current DNS Server 2 = :: System Information:System Model = PowerEdge R610System Revision = IISystem BIOS Version = 6.6.0Service Tag = Express Svc Code = Host Name = grollman-s0OS Name = Microsoft Windows Server 2012 R2, Standard x64 EditionPower Status = ON Watchdog Information:Recovery Action = NonePresent countdown value = 474 secondsInitial countdown value = 480 seconds Embedded NIC MAC Addresses:NIC1 Ethernet = 14:FE:B5:D2:94:72iSCSI = 14:FE:B5:D2:94:73NIC2 Ethernet = 14:FE:B5:D2:94:74iSCSI = 14:FE:B5:D2:94:75NIC3 Ethernet = 14:FE:B5:D2:94:76iSCSI = 14:FE:B5:D2:94:77NIC4 Ethernet = 14:FE:B5:D2:94:78iSCSI = 14:FE:B5:D2:94:79 [/INST] You can use iDRAC GUI to update iDRAC firmware. To update iDRAC firmware using GUI you need to download file "iDRAC6_2.92_A00_FW_IMG.exe" (This is a self extraction file) from dell support site (Link below) and extract to a folder. You can upload extracted "firmimg.d6" file to update iDRAC FW using GUI [URL] [IMAGE] </s>
<s>[INST] Hi, when first setup my r720 and put the System Mode to Performance per Watt the system was pretty quiet, the fans where running at 1200umin with less workload. Afterwards I played a bit with custom system modes or performance mode, ending in 12000umin fan speed all the time, no matter what's the temperature. I put the mode back to Performance per Watt, but the system is keep running with 12000umin, and a temperature of max 30¡Æ. Any idea how I can slow down the fans, or get back to the old behavior where the system was pretty quiet? Best regards, Fabian [/INST] Hi Chris, I simply run the following command using SSH on the idrac: > racadm set system.thermalsettings.FanSpeedOffset 0 This fixed the problem, the fan's are always quiet, now. Best regards, Fabian </s>
<s>[INST] Hi , i have a dell poweredge 2900 , yesterday was working good , but today i cant not saw image , the from screen is blue and not writing any problem, but the indicators for hard drives not blink. [/INST] You would need to call in for that information, we don't have visibility to essentially anything related to quotes or prices. It looks like the Costa Rica line is as follows: 0800 012 1845. </s>
<s>[INST] In OpenManage Essentials, email alerts were sent as plain text, and you could customize the entire message. In OpenManage Enterprise, you can still customize to some degree, but that's is just the message portion. The message is then wrapped in a huge HTML email with lots of other non-customizable information. We're sending emails to OpsGenie for alert handling, and these massive HTML emails gets really hard to read, with lots of unnecessary information. Can we please have an option to send plain text emails, and be able to customize the entire message please? [/INST] I am not certain that they read the forums, but I can submit your feedback internally to the powers that be and see what happens. </s>
<s>[INST] Hello, For the next planned upgrade: is it possible to buy and install Samsung PM1643 3.84TB 2.5" SAS SSD instead of the existing SAS HDDs? Do we need a special caddy for R820? Other known issues? Thanks! [/INST] The differences are dimensions, but more importantly is the latching mechanism on the front of the carrier. 12th gen [IMAGE] 14th gen [IMAGE] </s>
<s>[INST] I tried installing a U3N2-D low-profile USB 3.0 PCIe card in two FC630 servers, but the card seems to be unrecognized. I'm running Red Hat Linux and when I do an lspci I can see plenty of PCIe bridges including the X710 mezzanine card and the RAID controller that connects to the FD332, but I can't see the USB PCIe card. I think I noticed some link training errors during boot. Is this card just incompatible for some reason or is there something else possibly wrong? [/INST] I've seen a number of PCIe USB cards fail to work with our servers. I'm not sure specifically why, but I can tell you that there aren't any validated ones. The best recommendation I could make to you would be to make sure that the firmware is all up to date, but I'd still suggest tempering your expectations with that card. </s>
<s>[INST] Hi all, I'm hoping you can help clarify this for me We are using MLAG setups for the first time, we are using Dell N3000 series switches and have noticed that:Endpoints which are multi-homed and setup according to the newest docs (one ethernet connection in each peer switch) only communicate if I disable spanning tree on the peer link port channel. The only documentation I can find says the following:March 2014 - disable spanning tree on the peer linkSeptember 2016 - enable spanning tree on the peer link and DO NOT disable. If I have spanning tree enabled the setup does not work. Is there any reason why I would need spanning tree on? Cheers Andrew [/INST] Hi, No you shouldn¡¯t need it on if there are not any loops. </s>
<s>[INST] We've faced the issue while we extend HDD by insert full 24 slots. - Previously 12 HDD are 300GB of capacity - Insert new 12 HDD Capacity size 600GB We have 2 spare HDD 300GB and 600GB but spare 300GB alert : Disk too small. How to fix this issue while customer don't see the alert ? Thanks for advance. [/INST] Hello, You are running older EQL firmware. It created a new RAIDset using the full 600GB drive size instead of 300GB. So if a 600GB drive should fail the 300GB drive won't be able to replace it. In the short term you will need to get another 600GB drive and replace the 300GB spare. That will stop the message. All future drives as they fail must also be 600GB. Regards, Don </s>
<s>[INST] Dear experts, Im using Dell Poweredge R730, i have 8x 1TB disk. 4 Disks already setup to RAID5 last 3 years. I bought new 4 Disk since need more space on the server. I want to split 8 disk = 4 Disk / 4 Disk into multiple raid (RAID 5). I know it's possible to create a multiple raid on OMSA on the virtual disk section. My question is: Is there any effect on the old 4 Disk since i want to create 1 more VD on OMSA. *Sorry im new in this industry, if you guys need more information please let me know. [/INST] Hi Alex, Yes, you can set up multiple RAID 5s in this manner without creating any issues. You can go into either OMSA or the iDRAC and use the web GUI to deploy a new virtual disk, and it will also let you manually select the disks. This way you'll know exactly what disks are being touch with this second RAID container. </s>
<s>[INST] Hello, I try to install three GPU Nvidia Tesla M60 in a Dell R740. I use GPU install kit, that come with a cable that have one connector with 6 pins, and the other connector have 6 pins + 2 pins. The Tesla M60 have a power connector with 8 pins. So...I connect 6+2 pins in Tesla GPU Power connector, and the other connector side in the mother board power supply. When i have the three GPU connected, the server don't power up. The PSUs are alerted (orange blinked). When disconnected the GPUs, the server power up. The questions is: Its necesary and extra power cable to connect the GPUs to the power? I find in the Tesla manual, that is not compatible connect directly an PCIe cable power to GPU. Tesla M60 Cable Attachment Support Notes: CPU-8-pin auxiliary power cable attached: Supported; required. CPU 8-pin cable must be attached. CPU 8-pin cable must carry up to 240 W. PCIe 8-pin cable: Not supported. PCIe 8-pin cable is not compatible with CPU 8-pin board connector. Plugging in forcibly can cause permanent damage to the board and the system. In Dell manuals and docs, i not find any issue with cable power that come in install kit. Any sugestions? Thanks in advanced! [/INST] Hi, The GPU install kit, are you referring to this: [URL] the GPU enablement kit. The power cable should connect to the riser power connector, located at the end of the riser. Try install 1 GPU at a time. What PSU watt are you using? The PSU settings must be set to non-redundant. </s>
<s>[INST] Estou com um servidor R530 onde adicionei 3 novos discos (vieram de um outro servidor) e que pretendo usar para criar um novo RAID, porem nao sai do status "foreign". Como devo proceder? Obrigado. [IMAGE] [/INST] Guibes, Entao voce quer criar um novo Disco Virtual, e nao usar nenhuma informacao das unidades? Se sim, entao voce pode tentar limpar o estrangeiro, como visto aqui, ou se nao ha nenhuma configuracao atualmente no controlador, voce deve ser capaz de criar o novo Disco Virtual usando a unidade, e ao concluir inicializar o Disco Virtual, que ira formatar e excluir o conteudo. Informe-me como funciona. </s>
<s>[INST] I'm fairly new to Networker and have a few questions hopefully someone with more knowledge and experience can help me with. This question is about backing up MS SQL server db's. Suppose there is a MS SQL server with several databases - with some of them in Full Recovery mode, and some of them using Simple Recovery. If I have a workflow that backs up transaction logs only, I end up with failures - because of the dbs in Simple Recovery mode. The workflow contains many separate/different SQL servers and most of them have dbs set to Full Recovery. The servers that have dbs in Simple Recovery mode will always show in NMC as failed (I also have a separate workflow that does full SQL server backups - no problems/failures with that) The way I get around the failure is to create a specific workflow just for the server with mixture of Full and simple Recovery to backup only the (transaction logs for) db's in Full Recovery mode. This works, but I am not sure if that is the right way to handle this situation. If we have several SQL servers set up this way (with mixed db modes, thus necessitating separate workflows), I would end up with many, many more workflows and managing them and keeping things straight would be far more difficult. Is my approach correct, or is there a better way to do this? Any input would be appreciated. [/INST] [NAME], Keeping separate workflows for different instances of a DB on SQL server is the best approach. Specially in your case where you have different recovery modes set on different instances. You could create a separate policy based on either application e.g. front end, middle ware , back end, logging servers for any application that you have in production, or you could segregate it based on the data type like SQL in one policy, Exchange in one, Linux FS in once and so on. </s>
<s>[INST] Trying to upgrade an r720 BP firmware from 1.00 to 1.03. Ive tried to update the firmware from the per720 bootable and live service Iso however, it either does not update or stated not avail for my system (something to that effect). The driver and download page show as per my service tag that 1.03 should be the latest firmware. firmware inventory shows; BP12G+ 0:1 ........1.00 My question is ... is the downloads page incorrect or do i need to do something?? System info; R720 LFF 8 bay [/INST] Deveng24, The reason it is failing is due to you not having that Backplane installed. The 1.03 firmware is meant for the expander backplane, which isn't installed if you have only 8 drive bays (it's only available for a 16 bay chassis). If you look here the latest version for the non-expander is 1.0.Hope this helps. </s>
<s>[INST] Hi Where can I download avamar data store gen4T installation & Configration guid? [/INST] This is the customer installation guide: [URL] But it only shows the absolute basics. It won't show you details on how to install & configure Avamar software. Installation is usually done by DellEMC or a certified partner who has access to SolVe. </s>
<s>[INST] We just purchased a new blade system (DELL FX2). Each blade is configured with two fiber HBAs that are connected to two new downstream fiber switches. Each downstream switch has an ISL connection to a switch connected to the VNX. Each blade's HBAs show up on the appropriate switch. Everything looks great. I zone the first blade, and all is well. All four paths show up in the 'initiator' screen in Unisphere. The host agent is checking in with the hostname. I can create a storage group and present LUNS. Terrific! I zone the second. Again, it's all good. Then I get to the third, and for some reason, switch's 1's paths do NOT show up! Switch 0's paths are fine. I double checked the zones. Deleted them. Re-added them. Disabled/Enabled the switch. I checked for the zones and aliases on the connected upstream switch. Everything looks great. I restarted the host agent, although I'm pretty sure the initiators should show up anyway. I can't understand why these aren't showing up Any idea of what I should try next? [/INST] This was resolved by cold booting the server. Warm boot didn't work. Once I did a complete shut down, it registered. Go figure. </s>
<s>[INST] Hi there, does anyone know for sure if the senders email domain can be something different than [NAME].com? The help of the ./connectemcConfig -h doesn't mention anything and in all examples I did find is the senders mail domain [NAME].com. thx Tom [/INST] Hello Tom, You need to use [NAME].com if you want your system to call home with the error. If you don¡¯t want your system to contact EMC with the error, then you don¡¯t have to use [NAME].com. Please let us know if you have any other questions. </s>
<s>[INST] I have a Dell PowerEdge R720 running Server 2008 R2. I was doing an SUU update to fix a display issue and included other updates. The update had a red x next to the Bios and IDRAC. After a restart, I ran into the IDRAC issue. Fans are running at full speed. I tried powering down and installing the bios/idrac through Support Assist. No luck. I would appreciate any guidance. [/INST] I tried the power cycle previously and it did not work. The problem was solved. I did not see the full solution, but it required using the server¡¯s SD Card drive to update the IDRAC. Hopefully that will help some of you move in the right direction. </s>
<s>[INST] Hello, On vnx5300, Flare on SPA is damaged. In this case, the SPB loads normally. How to restore Flare loading on SPA with SPB? There is one more similar array - fully working. Can he help in recovery? [/INST] I found a solution to the problem. There is a plugin for the Utility Toolkit - RAMDiskResizer.ipl. This plugin changes the size of the RAM disk. I do not know who wrote this script. Perhaps this plugin is from developers. </s>
<s>[INST] Hi everyone ¢¯it is posible to attach a mminfo resultset with the send Notificaction option avaliable on NMC? Actually I have this: smtpmail -s "Politica ${NSR Policy} and Workflow ${NSR Workflow} y Accion ${NSR Action} completada" -h mailserver-p 25 teamnetworker[NAME].com. I would like to attach this mminfo result: mminfo -xc; -s nserver2 -q "client=orasvr,family=Disk" -r volume,ssid,savetime,sscreate,sscomp,group,level,sumflags,sumsize,name | findstr cb | findstr full Thanks in advance [/INST] It looks as the smtpmail utility that comes with the NW software cannot handle attachments. So let me suggest this procedure 1. save the mminfo output to a file: mmminfo -q .... -r .... > filename 2. append the mminfo output file to the 'better' mail command. On Windows, I use the Powershell command 'send-mailmessage' where I - first assign the file content to a string variable $body = Get-Content $file | out-string - then add the content to the '-body' parameter send-mailmessage ..... -body $body Maybe there is even a more elegant way but nobody is perfect </s>
<s>[INST] Hi, I'm using 3.3.1 and have just installed the power manager plugin. I can see the Widgets on the dashboard, but when I try to 'add groups' there's nothing to select; none of my static or dynamic groups show up. Am I missing something obvious? Thanks! [/INST] Hi, You would need to first add the groups to the Power Manager before they can be selected and added to the Widgets. This can be done by navigating to Application Settings -> Consoles and Extensions. Under Extensions - Power Manager, on selecting More Actions -> Settings, you will have the option to add Devices/Groups to Power Manager. Please note that Power Manager only supports Static groups. Hope this helps. Thank you. </s>
<s>[INST] Hi All I am fairly new to the OME API stuff, but i am learning. I wonder if there is any way to add a static group to a baseline using the REST API. I looked in the documentation but i could only find a POST method for baselines to create a new baseline. Any help is highly appreciated.Thank you! [/INST] Andi1234567, It does not appear like editing the baselines is supported. It only looks to support creating them from scratch with the POST method. Hope this helps. </s>
<s>[INST] -EMC R515 : updated BIOS,iDRAC,PERC card. Server has 1 RAID1 array and 1 RAID5. In the RAID5 array one disk is defective. I replaced it with a similar refurbihed disk I bought online. The array does not rebuild. I notice a difference between the existing disks and the new refurbished one. -The size is different (smaller then the original disk). A restore might not be possible because of this. - The model is , although on the disk itself the model is ST33000650SS printed, different then the other running disks. - The disk is not certified -the vendor is SEAGATE, and not DELL (sector,speed,.. are OK) I tried to clear the disk. And I think of the above, making it a hotspare fails. (Read somewhere this can start the rebuild.) I looks like it is not correctly recognized. [IMAGE] [/INST] Yes, it will just be slightly smaller than the current one. </s>
<s>[INST] What version of TLS comes with Celerra NS-480? where do you check TLS version on Unisphere on this old NAS device? Is it possible to upgrade the TLS version from 1.0 or 1.1 level to 1.2 level at 6.0.70-4? Is there any document that shows TLS compatibility Matrix with EMC NAS and Black storage products in general, and Celerra older versions in particular? I appreciate your assistance on this Sam.W [/INST] There isn¡¯t a place to check it that I am aware of. </s>
<s>[INST] Hi to all, I have bought 2 new CPU (E5-2660 v2) for my R620 with 2x E5-2603). After the change of the CPUs the server recognize only 1, the CPU1 and not the CPU2. I have passed all the day to updgrade BIOS and Idrac firmware (1 by 1 from the oldest to the newest) but always the same problem. The server start, the fan start at max speed and remain in this state, esxi 5.5 start but before the final screen the system reboot. Thanks for the help [/INST] If none of the CPUs are working with CPU socket 2, I'd be looking at the motherboard as a potential failure. If the old CPUs continue to work with CPU socket 2, you could test the new CPUs on a different motherboard. Updating the BIOS and iDRAC shouldn't impact the PSU at all, but you can perform a power drain, just to be safe. This would be done by shutting the server down, unplugging it, then holding the power button down for 30 seconds. You can then bring it back up as normal. </s>
<s>[INST] Hi All; I am looking for any storage like as Quantum, HP, that can be compatible with avamar 18.1 (as like as Data Domain can connect to avamar to backup data). Thank you. [/INST] Don't think you'll have much luck. DataDomain is the only Dedup Appliance supported by Avamar. Avamar is its own Backup/Dedup Appliance. DD Support was added because they're both from DellEMC. Avamar Clients also have the DDboost library integrated so they can write their backups directly on the DD (as does Veeam). Metadata is still stored on the Avamar Node/Grid. There's no equivalent to DDboost on a Quantum DXi, for example. That appliance has some extra integration with NetBackup (OST/DAE) or Veeam, where the Veeam Data Mover service can run directly on the DXi. </s>
<s>[INST] Hi, We have a policy/requirement to encrypt all network traffic at a minimum of TLS 1.2. I am trying to find out how to explicitly prevent our OpenManage vCenter Integration appliance accepting TLS1.1 or lower. Thanks [/INST] You'll want to make the TLS configuration setting with the iDRACs. I'm not seeing any location to make TLS setting changes in the manual, I know the DRAC web UI does. If you need OMIVV to specifically reject any connection below 1.2, we'll need to do a feature request. I can get that submitted, but I'd need to ask you a couple questions that would probably be more appropriate in a direct message. </s>
<s>[INST] We are using CloudPools with Azure as an archive. We use SyncIQ to copy a directory structure to a new location in another Access Zone. We break the SyncIQ relationship to make the target writable (essential). There is a FilePool policy that migrates the data at that target to Azure. Lastly we TreeDelete the original source files. All that works fine. My problem is in retrieving data. As it is an archive we do not want to use 'isi cloud recall' as that brings the actual file data back, replacing the SmartLink. I absolutely need the data to stay safe in Azure, where it has redundancy that we cannot provide on-site. There are documented 'CloudPools expected behaviors' that state: 'You can view and modify cloud data by accessing SmartLink files through supported protocols (NFS, SMB, Swift, and HDFS). If you attempt to access a SmartLink file directly on the cluster, through a command running on the cluster, or through an unsupported protocol, an I/O error is generated. Local access for SmartLink files is blocked for these commands: tar, gzip, scp, AVscan, and Job Engine jobs. Cloning of a SmartLink file is also prevented and will return an EINVAL error.' I have tested just using 'cp' to copy a SmartLinked file back to another location on the local Isilon. It doesn't give an I/O error as it suggests above. It retrieves the data content and caches it with the SmartLink, much as I would expect if I had used one of the supported 'redirected' protocols listed (SMB, NFS, HDFS and Swift). It is of course slow. I am reluctant to create a share and use an external server just to get a copy of the data back if a user requests it. That would mean creating a share on the archive access zone, and a target share where I need to put the data, and using an external server to pull the data back from Azure, and then store it back into the Isilon. That clearly is supported, but if I can use 'cp' locally that would avoid the data going 3 times across the external interfaces. So I guess my question is, whether what I observed was just luck, or is there any redirector for 'cp' or any other local commands? William [/INST] works as designed From the OneFS 8.2 Release Notes: SmartLink files and inline access In previous releases, the connection between OneFS file system storage and cloud storage was known as a stub file. Now, this connection is called a SmartLink file. SmartLink files permit inline access to the archived data.Inline access enables users connecting to a cluster through supported protocols to access cloud data directly through a SmartLink file, rather than requiring a connection from a client computer. hth -- Peter </s>
<s>[INST] I have an old R515. I want to reuse this as testmachine ans educational purposes I was able to approach iDRAC. It seems to be a dedicated port, but in the iDRAC settings the options is set on "Shared". "Dedicated" is not available. After a few reboots the DRAC was not reponding anymore. The lights on the DRAC NIC do not turn on anymore. The nic seems dead. I have no boot errors. I can alter the iDRAC settings by hitting F10 in the boot options. I there a way to "revive" the iDRAC NIC? [/INST] From screen shot looks like you are trying to upload file "iDRAC6_1.95_A00_FW_IMG.exe". "iDRAC6_1.95_A00_FW_IMG.exe" file is self-extractable application. You can double click and extract the content to a folder. "firmimg.d6" file on that extracted folder is the iDRAC image file and you need to upload this file on iDRAC </s>
<s>[INST] I am trying to test EMC CTA/VE v12.0.1 My destination is Azure cloud The source is a celerra NS480 The target verifies fine......so does the source. The policy i created is set to archive everything above 8k in size. In the sched, I have it pointing to a directory on the NS480 that has a handfull of files...all over 1 meg in size. I run the job. 0 success, 0 failure, 0 total size. any ideas? [/INST] something must have been wierd with the files I was testing on. I took a copy of the folder I was triying to archive.....right click/copy and pasted it into the same folder level.....those files archived just fine. </s>
<s>[INST] Trying to determine what type of UPS to buy that will have enough wattage to handle my R710's. Servers: R710 750w x 2R710 550w x 2 My plan is to buy two of these:CyberPower CP1500AVRLCD Intelligent LCD UPS System, 1500VA/900W, 12 Outlets, AVR, Mini-Tower For the 750w rig, connect one power supply to the first battery backup outlet and one to a non battery backup outlet on the first UPSFor the 550w rig, connect one power supply to the second battery backup outlet and one to a non battery backup outlet on the second UPS Does that sound like an acceptable solution or is that not wise? I don't need both power supply's on backup but I would like to have one and just have them gracefully shutdown if we have an outage that lasts 1 or 2 minutes. [/INST] That will be plenty, Id think. An R710 will sit at around with no load 200w, 0.6amp/ so that will be around 20mins+/- runtime, are you adding switches and other hardware to the UPS as well? The software will allow you to choose from max run time and power off at 5min power left,,or max power-saving and put the server into a low power state as soon as an outage is detected after a set time. the one i have is the CyberPower VALUE2200EILCD Value Series (1320W/2200VA) that runs my pc for a good 45mins on battery at 190w </s>
<s>[INST] Hi All, i wondering if I could get assistance with this problem. I have gone through the usual setup for idrac 9 set up during start up and selected the dedicated idrac port option, however the port just does not want to come. Please can someone suggest some ideas. I have an enterprise licence. Thanks, Ash [/INST] From the output looks like there is no link on dedicated port. Can you ensure port 2 in below diagram is connected. Also let me know the iDRAC FW version installed on the system (You can share "racadm getsysinfo" command output). Is speed/duplex is configured on the switch port where iDRAC is connected [IMAGE]T440 Rear </s>
<s>[INST] I am configuring a Dell EMC PowerVault ME4 4024 with 10 11tb drives, using RAID6. In the management software it shows that we have 88tb available, the expected 20% reduction, but when the ME4 is mounted as a file system only 86tb is available. We have a similar issue with our ME 4084, where a pool with 125tb available storage only 114tb is usable when mounted. We have some 3xxx units as well, that do not have this storage loss. The server we are using is RHEL7.7 [/INST] I found the problem, the Management Software defaults to base10, while the servers accessing the datastore default to base2. Matching the bases removed the discrepancy. </s>
<s>[INST] I upgraded a server from 2008 to 2012 R2. I believe this server had the first installation of SAN Headquarters installed. I also have the SAN Headquarters app on my local PC desktop. The app failed on to run on the server so I re-installed it - it prompted for the log directory - I could not locate a log directory locally but I believe I found the log on a network file server - so I pointed to i t. I also copied the folder to the local C: Drive of the server the SAN HQ app is running on. How do I change the Group settings for Default Server to point to the log files? I tried to change the location but I am in "Read only" mode. Is this the correct log files? folder name v2.6.0.6787-Feb-29-2016 .... contains grplog files and others I have no problem starting from scratch if that is the resolution. If so, how do I configure the app to start logging as of today. Thanks, Milty [/INST] Thanks for info - turned out to be wrong IP in documentation of former admin. Milty </s>
<s>[INST] Got the RS-232 for this and that works. Trying to set a IP and it shows it right but going to it's IP page can't be displayed. I set it to factory defaults. Looks like I have to type "enable" 1st thing. Then this: Dell SW1#show ip interface Management Interface: IP Address..................................... 192.168.86.29Subnet Mask.................................... 255.255.255.0Default Gateway................................ 192.168.86.1Burned In MAC Address.......................... 0019.B99C.D547Network Configuration Protocol Current......... NoneManagement VLAN ID............................. 1 Routing Interfaces:Netdir MultiInterface IP Address IP Mask Bcast CastFwd---------- --------------- --------------- -------- --------vlan 2 192.168.2.1 255.255.255.0 Disable Disablevlan 3 192.168.3.1 255.255.255.0 Disable Disablevlan 4 192.168.4.1 255.255.255.0 Disable Disablevlan 5 192.168.5.1 255.255.255.0 Disable Disable Dell SW1# So the IP is right 192.168.86.29 and the gateway too. Is there some Ethernet port I should plug this in to? I plugged it in Ethernet 1 and 45. Been looking a long time on here and a lot of commands they say to do I get errors from them. I want to update it but need to get a IP for it so I can get to it on my LAN 1st. Seems like have to be in moods for some commands to work like I did this: Dell SW1#console^% Invalid input detected at '^' marker. Dell SW1# Looks like can't go in that mode when in this mode. Here is a command that works that show it's version. Dell SW1#show switch Management Preconfig Plugged-in Switch CodeSwitch Status Model ID Model ID Status Version------ ------------ ------------- ------------- --------------------- --------1 Mgmt Switch PCT6248 PCT6248 OK 2.0.0.12 Dell SW1# So how do I set this up to get on it's web interface though my LAN as a IP of 192.168.86.29 picked that because nothing else on my LAN is using it now. I did try DHCP but it never got a IP. -Raymond Day [/INST] Got the webpage working like this: console#show ip http HTTP Server is Disabled. Port : 80 console#configure console(config)#ip http server console(config)#exit console#show ip http HTTP Server is Enabled. Port : 80 console# Wow got it working after a long time. -Raymond Day </s>
<s>[INST] Hello, I've setup and configured OME 3.3.1 everything seems to be OK. SMTP settings work, I am able to send reports to email. The email alert policy is configured, but new alerts are not sent. Does someone have the same problem or can anybody assist me? Regards Rainer [/INST] Would you verify if you have the "Application" category with the "System Health" subcategory, in addition to other categories you have selected and see if you are able to get the email then? If so, it is due to it being seen as an internal alert, and adding that category and subcategory should allow you to get the email alerts.Let me know what you see. </s>
<s>[INST] Hi All; I have question about taking E20-598 exam. Should I take 2 pre-require (E10-001 and E20-001) ? I already passed EMCPA, ESSA-SAN & EMCSA exams in 2006 & 2007. Thank you. Tom [/INST] Hello again Tom, [URL] Our free practice test is here [URL] Yes, at Pearson VUE testing center or online proctor (if you're in US) Thank you! Naomi [NAME] </s>
<s>[INST] Hi everyone: I am moving manually with nsrclone from disk to tape, everything is working well. I can see the savesets on the tape via GUI. [IMAGE] But when i try to list all the files on tape with mminfo, the savesets moved manually with nsrclone not showing at all mminfo -xc; -q "Volume=GYN397L4,family=tape,copies=1" -r volume,ssid,cloneid,clretent,savetime,sscreate,sscomp,group,level,sumflags,sumsize,name > D:\RPT\serv02\serv02_lista_TapeGYN397L4_sscreate_All.txt Thanks in Advance [/INST] Wow, that was simple and do the trick. So the copies parameter query all ssid backedup independent if I look up for an specific volume, pool or client. Thanks again and again [NAME].1 </s>
<s>[INST] Hello, I need some advice about an issue. This is time issue with Equallogic FS7610(v4.0.400005)/PS6210(v9.1.4).In the monitoring panel i have messages about NAS 0 & 1 controller time is not synchronized with Active directory (delay is more than 270 sec ). NTP servers (same as Active directory) are set too, but it looks like that the synchronisation doesn't work. I set the right time (the same time as on the Active Directory server) in "group configuration"/"generality" panel.After 5 hours, the message still appears and i cannot use AD authentification, but the time is good in "group configuration"/"generality" panel .Is there another way to set time (another configuration panel) ? Or is it possible to manually synchronize NAS controllers time ? (CLI or another way) Thank you [/INST] Hello Antoine2M, Does your FS7610 logged in to the NTP server? Are your managment ports on your FS7610 in the same subnet as the NTP server? Please let us know if you have any other questions. </s>
<s>[INST] Hi, We noticed a regression with the connectX-4 Lx firmware versions 14.25.8000 and 14.25.1020. Flexboot tftpis very slow [/INST] Bug fixed with recent firmware </s>
<s>[INST] Hi guys, we have bought a powervault me4 with one expansion. So, I saw the admin and technical manuals but i can't find any information how to connect only one expansion (the documention cover only more expansion). Can i use any port of expansion (except B port) like san controller 1 -> expansion port A and san controller 2 -> expansion port C? thanks Andrea [/INST] Hello Andrea, Here is the link to the deployment guide for an ME4. If you look on page 18 it explains and shows you how you want to cable your expansion enclosure. [URL] To connect just a single expansion enclosure all you need to do is to connect one cable to each controllers expansion port, & the other end to the expansion enclosure. Please let us know if you have any other questions. </s>
<s>[INST] Hello, I was connected with mstsc to the management console of a M630. The script I ran failed and closed both windows. I have only a blank screen left. The blade and it's VM are running fine and I can connect to the web interface. Another issue I have is that if I connect with the virtual console I can't hit ESC to change the user/sign-in methods. Furthemore I have to hit CTRL-ENTER. I already tried to reset idrac. How could I log back in the console without restarting the blade? [/INST] I needed to type ctrl+alt+end from the virtual keyboard. From there I could open the task manager and start cmd and sconfig. </s>
<s>[INST] I'm getting the following error on boot: Foreign configuration(s) found on adapter. Press any key to continue, or ¡¯C¡¯ to load the configuration utility or ¡¯F¡¯ to import foreign configuration(s) and continue. The problematic VD is just a single disk configured as a 1-disk RAID 0. I tried importing the foreign configuration but the server did not boot to OS (this is the OS disk, boot device not found) and when I rebooted I still had the same message so it looks like the import didn't work. So I tried to do the import again but this time by going into the configuration utility thinking it would show me an error message if it fails but again no error and it did not boot to the OS. I have taken out the disk to do a backup and to check it, I have found a bad sector which I have corrected with chkdsk. I would rather recover from this without losing the data on the drive, what should be my next step? [/INST] The RAID controller box was checked. Since I didn't get a reply yesterday I went ahead with the retag solution. I created the virtual disks using what I believe was the right parameters but the data ended up being wiped. By the way I did it with iDRAC's web interface and it did not warn me when creating the virtual disk that data would be wiped. I tried again this time in the BIOS and it did warn me data would be wiped. I just restored the backup I had taken beforehand on the new virtual disk so my problem is resolved. </s>
<s>[INST] The support newsletter can be referred here - IDPA Monthly Support Highlights - December-2019 [/INST] See updated Top Service Topics- as shared in discussion by that name by admin Chris: [URL] If this was useful please give KUDOS. thanks </s>
<s>[INST] Hi everyone, I have a SC5020 compellent storage and I have searched the place in Storage Manager to be able to do maintenance backups of all the configurations, but without success. Where can I find the backup option? thank you [/INST] Hello 851d229, There is not a way for you to backup the configuration of your SC5020. In a case where we would need to reload the configuration you would need to be on the phone with support and they can reload the configuration if needed. Please let us know if you have any other questions. </s>
<s>[INST] Hi all, One Dell OMSA 8.4.0 and several Dell OMSA 9.1.0 has issues logging in IE11 When I login in, IE11 redirects me back to the login screen without any failure or message. A lot of other Dell OMSA are working fine and have the same versions. Because I've two versions of Dell OMSA I started checking the IE 11 versions and this is my conclusion, seems to be the newest IE11 versions are not working with Dell OMSA: Version lower and equal then IE 11: 11.3085.14393.0 11.0.135 (KB4507434) are working fine. Dell OMSA is part of Local Intranet or Trusted Sites, also tried it to disable enhanced security, but still no result. So I think it has something to do with the latest versions of IE11. Has anyone also experienced this with the latest versions of IE11 and if yes, is there a workarround or solution for this? Thanks and regards Corne [/INST] Install Dell OMSA 9.3.0 will solve the issue. </s>
<s>[INST] Hi everybody, We have different CCR clone jobs on Networker. I know how to auto start enable/disable manuelly. But I want to autostart one of the CCR job in a row. I mean when it finishes, it has to start immediately. Is it possible to arrange it like that? [/INST] Ok, so there is an option in the workflow to change the interval of the scheduled start. The default value is 24 which means that work can run once a day. Making it 12 ensure that it runs twice in 24hrs. You could may be make the interval small enough say 1, so that when the workflow completes it gets started again within the next 1 hour. </s>
<s>[INST] Hello team, We have DDVE 6.2 and would like to upgrade to 7.0, there is no .rpm files to do so, as they are for physical machines? Any tips? [/INST] Opened SR, support uploaded it via SFTP, saying this is known bug.System upgraded everything ok. </s>
<s>[INST] Hi anyone, I have just inserted two new DELL 3TB hard drives to my T710. They blink 10 times Green and then blink Amber and only shoe in iDRAC as PDs but have NO size. Not able to add to New VD Array either. Any Help please? I am new to setting up servers too, so please 'bear with me'. Thanks in advance I think the drives are NO good. I cannot format them even, thanks anyway [/INST] OzzieDave, Would you confirm a couple things for me? What controller is installed in the server? What is the part number on the drives themselves? Let me know and I can verify compatibility. </s>
<s>[INST] Hi All; How to check S/N on IDPA avamar ? Thank you. [/INST] Anyone know about that, please share it to me. Thank you. </s>
<s>[INST] Hi everyone, could anyone provide me any assistance please with updating the iDRAC service module on a Ubuntu 18.04 LTS installed R740 please? I've gone through the instructions correctly i'd have thought but i'm not a Linux admin, i'm a Windows admin so it's all a bit alien to me. 1. Logged into the iDRAC > iDRAC Settings > Settings. Clicked to Install Service Module. 2. I've then downloaded the OM-iSM-Dell-Web-LX-350-1862_A00.tar.gz file from the Dell website for Ubuntu 18.04 LTS. 3. Copied it to a folder on the Linux server and then extracted it with the 'sudo tar OM-iSM-Dell-Web-LX-350-1862_A00.tar.gz' command. This extracted the files into the directory. 4. The instructions on the Dell website then say to run 'sh setup.sh' but i keep getting the error 'setup.sh: 72: setup.sh: Syntax error: "(" unexpected (expecting "fi")' Does anyone know what i'm doing, if anything, wrong? [/INST] Thank you, apologies for the delay in getting back. Your suggestion resolve the issue, it was sudo bash setup.sh that i needed to type which got it working and the OS is now reporting properly to iDRAC </s>
<s>[INST] Hello, I'd like to add my 8192 ssh key to iDRAC, but it seems to be too long: After looking for this error, I found this article that says it's supposed to be solved with firmware 2.40.40.40. I'm on 2.63.60.62 but the issue remains. As I don't plan to regenerate an other SSH key specifically for the iDRAC, is there another workaround ? Does Dell plan to fix this issue ? Thank you. [/INST] Aqwserf, The 8192 ssh key is indeed too long, as the max length would be 4096. The article you referred to was addressing the issue that 4096 keys were also being flagged as too long with SSH 6.6, hence the workaround was to create the 4096 with an older tool. The 2.40.40.40 update resolved the 4096 being flagged as too long, not to increase the key length itself. Hope this helps. </s>
<s>[INST] Guys, I need to power down VNX 5300 unified completely. Replace the component and power back up. Please share the procedure to power down the full storage and then power back up once ths task is completed. Thank You [/INST] Just go to mydocs.emc.com You can generate those documents there. Just select Model and type (Unified) and it will generate PDFs for you for the power off and power-on procedures. Unisphere should have a Power Off option, then it can properly shut down everything. Power on order is: DAEs, then DPE, then Data Movers, then control station(s). The documents will show you what status to wait for until the next step. But what component do you need to replace that requires a complete shutdown? </s>
<s>[INST] Apparently the problem arose about 1 year ago, after updating Flare from R31 to R32. SPA did not complete the update. Although there were no errors in Unisphere. I'm trying to upload a MIF image for R32 to the SPA. But there was a problem - the version of the Utility Toolkit on the SPA from R31 and the RAM disk is limited to 2.5GB. But the image from R32 has a size of 2.8 GB. This image does not fit into a RAM disk when downloading via FTP. How to solve this problem. Can I upgrade the Utility Toolkit to R32 separately? How to do it?And the second question is - I have SPB in working condition. Is it possible to restore SPB from it? Preferably without stopping the array. [/INST] I found a solution to the problem. There is a plugin for the Utility Toolkit - RAMDiskResizer.ipl. This plugin changes the size of the RAM disk. I do not know who wrote this script. Perhaps this plugin is from developers. </s>
<s>[INST] Hi, I am new to these Devices, in my environment we have 2 Dell EquilLogic devices and we got Failed drives on both devices. These are out of support i believe Slot Type Model Size RPM Status Errors SMART Health---- -------- ---------------- ----------- ----- --------- ------ ------------ 1 SAS(HDD) Unavailable 0MB 10000 failed 0 unavailable 2 SAS(HDD) Unavailable 0MB 10000 failed 0 unavailable 7 SAS(HDD) Unavailable 0MB 10000 failed 0 unavailable Is it straight forward to replace these? Like Order new Drives and pull the failed once and replaced with new? If not do i need to follow any other steps from CLI or GUI before and after the replacement? One more Query: I can also see it has some failed components but it's now showing what exactly failed?? Is there a way to find out what failed here? Health Status Details Critical conditions::Critical hardware component failure. Warning conditions::More spare drives are expected. any help would be a great help and much appreciated. Thanks in advance._______________________________________________________________________________ [/INST] Hello, RAID50 is two RAID5's striped together. So each RAID5 stripe can only handle one drive failure. You should have also had two SPARE drives? Which should have replaced the failed one automatically. if not, or if you were running with 'no spares' option then the another failure on either RAIDset will cause an outage of that entire array. Once you resolve the failed drive situation you might want to consider converting to RAID6. Regards, Don </s>
<s>[INST] Hi every one, I am moving several savesets manually with this command nsrclone -v -s srvres -b "pool HIST" -S 4077588109 > D:\RPT\srv12\log_srv12.txt I need to save the output for reporting purpose but when i check the txt i only get. Obtaining media database information on server srvres NSRCLONE completed. ¢¯How can i get all the action as txt output? or ¢¯Where are the logs when i manually execute an nsrclone o nsrstage command ? thanks in advance [/INST] You better redirect stdout & stderr to the output file. For Windows the command would be like: whatever_command > file 2>&1 BTW - there is no output file for a manual nsrclone job. </s>
<s>[INST] Hello, Currently we have two new Brocade switches for a migration activity.We want to free up two ports by SP in VNX 5500. One of of these are mirrorview ports (by SP). We don't have replication now so these ports are unused.Is possible to use these ports like storage ports? Our aim it will be to create a zone configuration using these ports. Many thanks in advance.Regards. [/INST] Yes, VNX mirrorview ports can be used like normal storage ports. You can zone hosts to these ports normally. </s>
<s>[INST] Hi all, I have a poweredge r620 server. The system was very stable until recently, after added additional RAM modules I get random reboots. I found the following critical errors in the iDRAC logs: 2020-01-08T18:12:58-0400 CPU0704 CPU 1 machine check error detected.2020-01-08T18:12:56-0400 PCI1320 A bus fatal error was detected on a component at bus 1 device 0 function 0.2020-01-08T18:12:51-0400 PCI1320 A bus fatal error was detected on a component at bus 0 device 2 function 0.2020-01-08T18:12:47-0400 PCI1360 A bus fatal error was detected on a component at slot 1.2020-01-08T18:11:33-0400 PCI1360 A bus fatal error was detected on a component at slot 1.2020-01-08T09:29:34-0400 CPU0704 CPU 2 machine check error detected.2020-01-08T09:26:30-0400 CPU0704 CPU 2 machine check error detected.2020-01-08T09:24:57-0400 CPU0704 CPU 2 machine check error detected.2020-01-08T09:24:07-0400 CPU0704 CPU 2 machine check error detected. I am trying to figure out if this error is related to the new memory modules, so I would like to understand the following: 1) how can I know which component is the "component at slot X" 2) what does "CPU machine check error" mean? 3) How can I identify: "bus 1 device 0 function 0."? From the below is the lspci output from esxcli, I would understand that 0:2.0 corresponds to: 0000:00:02.0 PCI bridge Bridge: Intel Corporation Xeon E5/Core i7 IIO PCI Express Root Port 2a [PCIe RP[0000:00:02.0]] What is the PCIe Root Port exactly? ===================================================== 0000:00:00.0 Host bridge Bridge: Intel Corporation Xeon E5/Core i7 DMI2 [PCIe RP[0000:00:00.0]]Class 0600: 8086:3c00 0000:00:01.0 PCI bridge Bridge: Intel Corporation Xeon E5/Core i7 IIO PCI Express Root Port 1a [PCIe RP[0000:00:01.0]]Class 0604: 8086:3c02 0000:00:01.1 PCI bridge Bridge: Intel Corporation Xeon E5/Core i7 IIO PCI Express Root Port 1b [PCIe RP[0000:00:01.1]]Class 0604: 8086:3c03 0000:00:02.0 PCI bridge Bridge: Intel Corporation Xeon E5/Core i7 IIO PCI Express Root Port 2a [PCIe RP[0000:00:02.0]]Class 0604: 8086:3c04 0000:00:02.2 PCI bridge Bridge: Intel Corporation Xeon E5/Core i7 IIO PCI Express Root Port 2c [PCIe RP[0000:00:02.2]]Class 0604: 8086:3c06 0000:00:03.0 PCI bridge Bridge: Intel Corporation Xeon E5/Core i7 IIO PCI Express Root Port 3a in PCI Express Mode [PCIe RP[0000:00:03.0]]Class 0604: 8086:3c08 0000:00:05.0 System peripheral Generic system peripheral: Intel Corporation Xeon E5/Core i7 Address Map, VTd_Misc, System ManagementClass 0880: 8086:3c28 0000:00:05.2 System peripheral Generic system peripheral: Intel Corporation Xeon E5/Core i7 Control Status and Global ErrorsClass 0880: 8086:3c2a 0000:00:11.0 PCI bridge Bridge: Intel Corporation C600/X79 series chipset PCI Express Virtual Root Port [PCIe RP[0000:00:11.0]]Class 0604: 8086:1d3e 0000:00:16.0 Communication controller Communication controller: Intel Corporation C600/X79 series chipset MEI Controller #1Class 0780: 8086:1d3a 0000:00:16.1 Communication controller Communication controller: Intel Corporation C600/X79 series chipset MEI Controller #2Class 0780: 8086:1d3b 0000:00:1a.0 USB controller Serial bus controller: Intel Corporation C600/X79 series chipset USB2 Enhanced Host Controller #2 [vmhba32]Class 0c03: 8086:1d2d 0000:00:1c.0 PCI bridge Bridge: Intel Corporation C600/X79 series chipset PCI Express Root Port 1 [PCIe RP[0000:00:1c.0]]Class 0604: 8086:1d10 0000:00:1c.7 PCI bridge Bridge: Intel Corporation C600/X79 series chipset PCI Express Root Port 8 [PCIe RP[0000:00:1c.7]]Class 0604: 8086:1d1e 0000:00:1d.0 USB controller Serial bus controller: Intel Corporation C600/X79 series chipset USB2 Enhanced Host Controller #1 [vmhba33]Class 0c03: 8086:1d26 0000:00:1e.0 PCI bridge Bridge: Intel Corporation 82801 PCI BridgeClass 0604: 8086:244e 0000:00:1f.0 ISA bridge Bridge: Intel Corporation C600/X79 series chipset LPC ControllerClass 0601: 8086:1d41 0000:00:1f.2 SATA controller Mass storage controller: Intel Corporation Patsburg 6 Port SATA AHCI Controller [vmhba0]Class 0106: 8086:1d02 0000:01:00.0 Ethernet controller Network controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet [vmnic0]Class 0200: 14e4:165f 0000:01:00.1 Ethernet controller Network controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet [vmnic1]Class 0200: 14e4:165f 0000:02:00.0 Ethernet controller Network controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet [vmnic2]Class 0200: 14e4:165f 0000:02:00.1 Ethernet controller Network controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet [vmnic3]Class 0200: 14e4:165f 0000:03:00.0 RAID bus controller Mass storage controller: Avago (LSI) PERC H710 Mini (for monolithics) [vmhba1]Class 0104: 1000:005b 0000:04:00.0 Ethernet controller Network controller: Chelsio Communications Inc S320-LP-CR 10GbE Dual Port AdapterClass 0200: 1425:0036 0000:05:00.0 PCI bridge Bridge: Integrated Device Technology, Inc. [IDT] PES12T3G2 PCI Express Gen2 SwitchClass 0604: 111d:8061 0000:06:02.0 PCI bridge Bridge: Integrated Device Technology, Inc. [IDT] PES12T3G2 PCI Express Gen2 SwitchClass 0604: 111d:8061 0000:06:04.0 PCI bridge Bridge: Integrated Device Technology, Inc. [IDT] PES12T3G2 PCI Express Gen2 SwitchClass 0604: 111d:8061 [/INST] Masedira, You can find the PCIE Routing Topology below, which shows you the slots and their associated CPU's [IMAGE] What I would suggest is clearing the hardware log and then remove the memory you added, just to test if the error repeats. If not then it may be the dimms, so let me know part numbers if you have them, so I may check on compatibility. I would also reseat the center and left risers, and the cards within. I would also look to see if the system is behind on BIOS, iDrac, and controller as well, if so I would recommend updating as well. Let me know what you see. Here is a page on finding Bus Device Function as well - [URL] </s>
<s>[INST] Hello, I am having an issue configuring a new iSCSI connection on a new Win2016 server. Standard procedure is to install Auto Snapshot Manager and then configure the VSS Chap and grab the servers Initiator Name and add it to the new volume on the SAN, limiting access to only that Initiator. We then limit the MPIO access to only the subnets used for SAN traffic and make sure the connections are building out over the SAN ports instead of the business LAN. My server is building out the connection over 10.20 subnet not following the settings I have set in Auto Snapshot Manager. Has anyone seen this before? I have attempted a couple uninstall reinstalls of ASM. I have several other servers configured the same way and operating properly, none of them connecting over the company LAN [IMAGE] [/INST] Hello, Make sure there is a trunk (or stacked) on the iSCSI switches. Also from the EQL Group CLI you want to ping out from each network port. GrpName>ping "-I It is a capital I GrpName>ping "-I 192.168.1.20 192.168.1.1" The quote marks must be included. Do this for every EQL network interface. You want to ping all the server iSCSI NICs. Regards, Don </s>
<s>[INST] Hi. Had performance issues on the 5 year old PowerEdge T320 Server that turned out to be a Windows Hyper-V Issue. I solved that issue. However, as part of the troubleshooting process I ran the Pre-Boot Dell Utilities. All tests passed, but the Fan Test caused the Rear Fan to be stuck on high. I don't have an IDRAC License. I don't have a Service Agreement. Our plan was to retire the Server later this year, so I am trying to avoid purchasing a Service Agreement and/or IDRAC License. I asked my Dell Account Manager if they could sell me something on the cheap since the issue was caused by running the Dell Diagnostics Tool, but the answer came back no. I have not updated the BIOS or the IDRAC Software or any other Dell Utility Software. Perhaps that will help and I can do that for free. Does anyone have any experience with this issue and if so, is it possible to fix without access the IDRAC Utility? Also, I tried installing SpeedFan, but it did not recognize the server chipset. SpeedFan detected the fan speed, but attempts to control the fan speed failed. Is there a way to get SpeedFan or anther utility to work to lower the Fan Speed? Any other suggestions would be welcome. Peter at Cebic Technologies [/INST] Hi Peter, Have you tried powering the server off, unplugging it, then holding the power button down for 30 seconds? This will force the iDRAC hardware to restart, which is would be desirable, because the iDRAC also functions as the fan speed controller for the server. </s>
<s>[INST] Dear all,I did setup a new S4128T with OS10 and set a management interface ip. Open [URL] in Chrome results in a white page. No pop up or windows for credentials comes up.Do I have to setup something special in the switch?RegardsJay [/INST] Hi, There is not a GUI interface for this switch, everything is done through the CLI. </s>
<s>[INST] Hi, We recently purchased some additional drives for our NX3230 to increase the capacity on one of the existing volumes. I've gone into the Lifecycle Controller to find a way to add these disk to the existing RAID configuration, but the only options seem to be to wipe the existing configuration and start from scratch. Does anyone have and information or guides they can share that explain how to expand the array/RAID? Cheers, Mark. [/INST] Hello Mark, What you will need to do is to go into the perc bios and in there it will allow you to expand the virtual disk. What you need to be aware of is that your NX3230 is going to do a restripe of the data to all the drives. When the data is being restriped, your virtual disk is going to be a raid0, until the restripe is complete. A restripe is a low priority process, if you are using large size drives the restripe can take a long time to complete. It is best & fastest when adding drives, to backup all the data first, then destroy the virtual disk. Once virtual disk is destroyed then create the new virtual disk with the correct size. Please let us know if you have any other questions. </s>
<s>[INST] Hi, I just got a used Poweredge R710. I am running Proxmox VE as my hypervisor. I need to enable the Virtualization option in my BIOS. However, whenever I enable virtualization, and I restart the server, the virtulization option is disabled. Is there a fix for this? [/INST] Hi, I was seeing this from the BIOS screen because I always went back into the BIOS to check. However, I have fixed the problem. The problem was the improper placement of the NVRAM Jumper on the motherboard. I corrected it, and my BIOS settings can save now. However, it still doesn't update. - Christian </s>
<s>[INST] Hi, Is there a way to access the vmax all-flash, powermax and vmax40K arrays without their GK devices..? or in other words... when a power failure happens with no accessibility to the unisphere or solution enabler servers, how can we login to our production arrays..? [/INST] Hi As long as the aclx device is configured you can access the array without gk's. In terms of no control hosts available you can use embedded management on the array itself to access the array also. Regards Fin. </s>
<s>[INST] Hi! I created a case with education support in November. I got a reply a couple of times (within a day or two), but after a reply with "I¢¥m already investigating what the issue is." - I have not received any more replies, even after a couple of mails from me. About mid-December I even created a new case, because this became rather urgent. Still no reply in neither cases. Has anyone else experienced this lack of feedback from education support? Our training credits are nearing expiration very soon, and I don't know what to do... [/INST] Hello stianj, Could you please send your case# and your request via. private email to me? Best, Naomi #IWork4Dell </s>
<s>[INST] Hello, I recently moved my SAN to a new IP address. I thought I changed all the IP addresses I needed to in the SAN configuration. The SAN is working fine. However, I am still getting automatic emails saying my SAN group is not responding to ping requests, because whatever program is pinging is pinging the old IP address. Here is the text of the emails that are being sent: This message was generated by the Dell EqualLogic SAN Headquarters service (version 3.0.1.7331) running on myserver.mycompany.comThe following conditions on Group MYSANGROUP (123.45.178.90) have generated an alert notification: Critical conditions: IP address 123.45.178.90 is the old IP address of the group and is no longer valid. What do I need to change to have the service/system/program (whatever it is) ping the new IP address (187.65.132.10)? Thanks. [/INST] Hello, It will only remove it from the SANHQ database. It will not actually do anything to the SAN itself. You might have to check the online help. There is a way to just have it not actively monitor the group but keep the old data. Otherwise you can export the archive then view it later inside SANHQ. Regards, Don </s>
<s>[INST] I rebooted a Windows 2012 server that had an iSCSI connection to an Equallogic 6100 SAN. Following the reboot I checked File Explorer and the X: drive was not present. I launched the iSCSI initiator app and the target displays as connected. I disconnect and connected. I checked Disk Manager - ran a re-scan - drive does not appear. I checked the SAN monitoring log and have the following message: Member MOC-MEMBER02Subsystem MgmtExecEvent ID 7.4.3 7.4.24Message iSCSI login to target '172.100.0.10:3260, iqn.2001-05.com.equallogic:0-1cb196-a04af794f-42c004f7b2856e9c-xx-xxxxx-xxxxxx' from initiator '10.100.1.4:49152, iqn.1991-05.com.xxxx.xxxxxx.xxxxxx.xxxxx' failed for the following reason: Requested target not found. I do see the volume but it is named "production" Tvideo" I assume it is contained within that volume. Is there a way to look into the volume to see its contents? What steps do I take to re-mediate the lost SAN drive connection? Thanks, Milty [/INST] I have created a new volume on the SAN and configured access control for one initiator IP address only. I removed all settings in the initiator. I launched the iSCSI initiator on the server and entered the IP for the SAN. I copied in the IQN of the server.The firewall on the server is off for testing. I do not have any targets listed on the Target tab. I have rebooted the server. </s>
<s>[INST] Hi, I'm working on trying to upgrade the firmware for a VNXe3200 device. When running the health check prior to the upgrade, I receive this error: "The health check has failed. A problem has been detected with a backend disk processor enclosure. Ensure that the backend cabling is correct. Error code: platform::check_for_enclosure_faults_2." Under system health for the DPE, I see this error: "The Disk Processor Enclosure (DPE) has faulted. This may have occurred because of a faulted SP." I've verified that the management ports for both SP's are connected to the network on the same VLAN and I'm able to ping them both. Using the IPMI Tool, I logged into SP A and B and ran and all tests show "The interconnect is OK". Verified that SP A is the master/primary SP. I've cleared boot counters with and rebooted both SP's. When the SP's boot, there's an error in the Log in the web GUI that says: System [storage] has experienced one or more problems that have had a major impact. I re-imaged both SP's with the following: Both the DPE error under System Health and the Health Check error are still showing. Unfortunately, I'm not very familiar with these EMC storage devices. Thanks in advance! [/INST] After running I got the following error in the "BIOS and EPOS Errors" section: I reviewed the EMCSystemLogFile.log under /EMC/backend/log_shared and found the following errors for both SP A and B: Determined the issue was both SP's had failed CMOS batteries (CR2032). After replacing the CMOS battery in both SP's, the health check passed and we were able to upgrade the firmware. </s>
<s>[INST] Hi All; I have question about upgrading avamar client from 7.5.0 to 18.2 , when I upgrade it, it pops up the windows 1) close the applications and attempt to restart them or 2) Do not close application. A reboot will be required I don't want to reboot server, which option do I need to choose ? Thank you. [IMAGE] [/INST] Fairly obvious answer. Let it close the application (or you can stop the windows service Backup Agent, which is the Avamar client service) Reboot should not be needed. </s>
<s>[INST] Hi, Not really technical but doe someone know if we can scrap n SSD with PROSUPPORT next business day support ? thanks, Vivek [/INST] I think disk retention is a separate option to your maintenance contract I would suggest to contact your service account manager to check </s>
<s>[INST] Hi, Forgive me if there is already a post on this, but I looked to make sure first. I'm running version 3.3.1 (Build 12) of Open Manage Enterprise. I noticed that the latest Dell catalog dated 12-22-2019 doesn't contain update releases dated few days prior. I'm guessing this might be expected since the catalog was released right after them. Does this usually happen? Thanks, Daniel [/INST] Yes, that is normal. There is a process to creating and publishing catalogs. I don't know exactly how long that process takes, but the catalog will only contain updates that were available when it was created. The time from creation to publish could be a few days or a few weeks. </s>
<s>[INST] Hello, we have installed successfully Solaris 11 on Dell Poweredge R440, I'm trying to download the SUU for firmware update but couldn't find the Solaris operating system.. can you advise on the way forward to update all components f/w Regards, nnakhle [/INST] Solaris isn't a supported operating system, so I think you'll have an easier time getting you updates streamed to you by using the iDRAC web gui. The iDRAC is able to pull the update full update catalog, same as the Lifecycle Controller. This way you can update all your components and you won't have to worry about any OS hurdles. </s>
<s>[INST] I have an interesting situation going on here. Two, actually. I am looking for recommendations hopefully in the PowerVault family for entry-level storage. I am looking for options that can easily attach to a PowerEdge R620 (the MD arrays are out according to my hardware tech; we are trying to avoid multi-amp devices), so what's left? And then I am also looking for a bit more storage for my home network environment, as well, which includes a couple of servers, but only a standard 120 volt 20 amp circuit. Recommendations would be great. Thanks! [/INST] Hello Cambridgeport90, For an entry level storage based on the information that you provided there isn¡¯t much other than an MD or ME. With the server that you are using your options are limited. As you can use a MD1200 to connect to your server and that will give you added storage space. However, you can¡¯t use a MD1400 as that needs a 12gb SAS card. Your PE R620 server will not support a 12GB sas card. Only our 13th gen & 14th Gen servers (PE R630 or PE R640) support 12gb sas cards. Please let us know if you have any other questions. </s>
<s>[INST] I've recently deployed the Openmanage Enterprise virtual appliance to manage our servers. It seems to work reasonbably OK with the newer (13G) ones (with a few issues), but barely seems to work at all with the one 11G model (R710) which I still have - it can't see its DNS name, and doesn't seem able to check it for firmware updates. Is this expected behaviour? I realise that the 11G server is quite old now so that may well be the reason. All of the servers have iDRAC Enterprise licenses. Thanks [/INST] OMEnt has limited support for 11g systems. 11g systems are reliant on OpenManage Server Administrator as an agent. The iDRAC6 has limited capabilities as an agent in comparison to later generations. OpenManage Essentials is designed to use OMSA as an agent. OpenManage Enterprise is designed to use iDRACs as agents. If you are going to be managing 11th generation or older systems then you will probably want to use OME instead of OMEnt. [URL] </s>
<s>[INST] One of the two controllers in our MD3000 started flashing the error LED, and the "show storageArray profile" command reports "Status: failed" for that controller. Data is no longer accessible via that controller.There is currently one virtual disk owned by that controller (no multipath setup). I tried to move that virtual disk to the second (good) controller with the command:set virtualDisk [home] owner=1;This failed with the message:Error 18 - The operation cannot complete because of an internal target error.Is there any way to access the failed controller's virtual disk before the controller has been fixed/replaced?Thanks in advance. [/INST] Hi, Do you have storage manager installed? [URL] Determine how the MD3000 is connected. </s>
<s>[INST] Hi All; I have rman backup, it ran 18 hrs to backup 3.4TB in last 2 weeks but now it takes 25hrs to backup same size (3.4TB), If I set number of RMAN Channels = 1 and Fileperset = 1 in dataset then the output is: 2019-12-26 10:18:53 avtar Info <6083>: Backed-up 8.000 GB in 3.06 minutes: 157 GB/hour (20 files/hour) If I set number of RMAN Channels = 1 and Fileperset = 2 in dataset then the output is: 2019-12-24 13:36:00 avtar Info <6083>: Backed-up 11.40 GB in 22.68 minutes: 30 GB/hour (3 files/hour) If I set number of RMAN Channels = 1 and Fileperset = 4 in dataset then the output is: 2019-12-18 11:01:41 avtar Info <6083>: Backed-up 19.28 GB in 31.46 minutes: 37 GB/hour (2 files/hour) Any suggestion on it , please ? Thank you. [/INST] fixed it </s>
<s>[INST] Hello everybody, this is my first timer here. I replaced my old Dell PowerEdge T330 server,(service tag , CPU Xeon E3-1230 v6 3.5 GHz, 4 cores, RAID Perc H330 2 x 1 TB SATA, 32 Gb DDR-4, UDIMM, 2400 MHz, Windows 2012 R2) with a new Dell PowerEdge R640 server (service tag , CPU Intel Xeon Silver 4114 2.2 GHz, 10 cores (RAID Perc H730 mini, 4 x 300GB SCSI, 64 Gb DDR-4, double rank, ECC registered, 2666 MHz, Windows 2016 ). The main use for the server is for running SCADA, and the corresponding Report application. During the testing of the new server, (Dell PowerEdge R640) we determined that the speed at which reports are generated is 40% slower cca, compared to the old server. Benchmark test show that the speed of the old memory is 29 Gb/s , and the speed of the new one is 25Gb. The software developer says that the Ram speed causes a slower report generation. [IMAGE] [IMAGE] The seller delivered the server with a 4 x 16 Gb, DDR-4, double rank, ECC registered, 2666 MHz, memory which was installed into: A1, A7, A2, A8. We tried the to make a memory arrangement: A1, A2, A4, A5, and while starting up BIOS it reported a mistake. [IMAGE] The PC works with memories arranged in the order : A1, A2, A3, A5, but the report generation is still very slow. How can we speed up the RAM? The PC is two months old, we already had a SSCI failure, and we had to replace the motherboard (it was not possible to activate the server)¡¦... Best regard Dusan [/INST] It sounds like slot 4 is bad. If the memory mode is optimizer then the memory should have been populated in slots 1,2,4,5. It appears that someone put the memory in slots 1,2,7,8 because slot 4 was bad. Unless the memory is in some other mode it should not have been populated that way. I don't see a memory mode that would be populated 1,2,7,8. I would test other memory modules in slot 4 to see if the error follows modules or errors on every module in slot 4. If slot 4 is bad then the system board will need to be replaced. Maximum memory performance will require 6 identical modules in slots 1-6. </s>
<s>[INST] Storage: SC5020 OS: Redhat 6.9 Clustered. I did 750GB db restoration, during the job, I had to write and delete backup files on 1.5TB volume. Now the volume is pretty much empty (99%). However, SC5020 shows the volume is 97% full. It seems as the space emptied out in Red Hat doesn't reflect to SC5020. What is the proper way and command to send space reclamation from Red Hat 6.9 to SC5020? Thank you in advance. [/INST] To share with anyone. 1. from RHEL, # fstrim -v /dir1 (this will send SCSI UNMAP command to SC5020) 2. Expire all snapshots and coalesce last snapshot to Active Space. This will remove all space occupied by snapshots and truncate the whitespace. </s>
<s>[INST] Hi, Im not sure how to properly populate RAM in a T640. I have two 32GB Dimms, Single CPU. Is it correct to put them into A1 and A5? [/INST] A1 and A7 share channel 0, per the owner's manual. A5 would share channel 4 with A11. I would populate A1 and A7. Page 106 goes into memory population guidelines in greater detail. [URL] (Pg 105) </s>
<s>[INST] I have ssh enabled and can login with admin[NAME] using password just fine. I created a ssh pubkey user/key (both with name "admin" and another name).Both entries have my pubkey though. When i try to login with "ssh -vvv admin[NAME]" i see this and still get prompted for the admin password though. Why? What else can i try? The pubkey that is being sent over (RSA 10:43:c7:58:...) is the one that i have pasted in the web UI (and can see and confirm there). I have it added in the ssh-agent, thats why ssh doesnt find it on the disk. ...debug1: Host 'mlmsw1-0' is known and matches the RSA host key.debug1: Found key in /home/support/.ssh/known_hosts:674debug1: ssh_rsa_verify: signature correctdebug2: kex_derive_keysdebug2: set_newkeys: mode 1debug1: SSH2_MSG_NEWKEYS sentdebug1: expecting SSH2_MSG_NEWKEYSdebug2: set_newkeys: mode 0debug1: SSH2_MSG_NEWKEYS receiveddebug1: SSH2_MSG_SERVICE_REQUEST sentdebug2: service_accept: ssh-userauthdebug1: SSH2_MSG_SERVICE_ACCEPT receiveddebug2: key: .ssh/id_rsa (0x7ff7b8455360),debug2: key: /home/support/.ssh/id_rsa ((nil)),debug2: key: /home/support/.ssh/id_dsa ((nil)),debug2: key: /home/support/.ssh/id_ecdsa ((nil)),debug2: key: /home/support/.ssh/id_ed25519 ((nil)),debug1: Authentications that can continue: publickey,passworddebug3: start over, passed a different list publickey,passworddebug3: preferred gssapi-keyex,gssapi-with-mic,publickey,keyboard-interactive,passworddebug3: authmethod_lookup publickeydebug3: remaining preferred: keyboard-interactive,passworddebug3: authmethod_is_enabled publickeydebug1: Next authentication method: publickeydebug1: Offering RSA public key: .ssh/id_rsadebug3: send_pubkey_testdebug2: we sent a publickey packet, wait for replydebug1: Authentications that can continue: publickey,passworddebug1: Trying private key: /home/support/.ssh/id_rsadebug1: key_parse_private2: missing begin markerdebug1: key_parse_private_pem: PEM_read_PrivateKey faileddebug1: read PEM private key done: type Enter passphrase for key '/home/support/.ssh/id_rsa': debug1: key_parse_private2: missing begin marker debug1: read PEM private key done: type RSA debug3: sign_and_send_pubkey: RSA 10:43:c7:58:dd:f2:2e:42:95:e7:8f:1d:3a:54:dc:59 debug2: we sent a publickey packet, wait for reply debug1: Authentications that can continue: publickey,password debug1: Trying private key: /home/support/.ssh/id_dsa debug3: no such identity: /home/support/.ssh/id_dsa: No such file or directory debug1: Trying private key: /home/support/.ssh/id_ecdsa debug3: no such identity: /home/support/.ssh/id_ecdsa: No such file or directory debug1: Trying private key: /home/support/.ssh/id_ed25519 debug3: no such identity: /home/support/.ssh/id_ed25519: No such file or directory debug2: we did not send a packet, disable method debug3: authmethod_lookup password debug3: remaining preferred: ,password debug3: authmethod_is_enabled password debug1: Next authentication method: password admin[NAME]-0's password: [/INST] Looks like i had simply not done this # ip ssh pubkey-auth But another question.I can only have one single key for one (e.g. admin) account? </s>
<s>[INST] Hello, I'm new to the Dell Server game. I will be needing to create a separate array to increase storage on my PowerEdge R630. I don't have access to connect the iDRAC connection at this point in time, working on it. Is there any Dell management software that can be added to windows 2012 that can build the array? Server is bare metal Windows 2012 R2. [/INST] OpenManage Server Administrator can do more than the iDRAC and should be installed on every Dell server you manage. Specifically, find downloads for the R630 running Server 2012 R2 here:[URL] OpenManage Server Administrator version for your system and OS:[URL] </s>
<s>[INST] Hi, We received new servers and I decided to create template in OpenManage from one of the R640 servers and then apply it to newly arrived servers. After that I updated all firmwares including iDRAC to version 4.00.00.00 and iDRAC stopped sending e-mail alerts. If I downgrade FW to 3.36.36.36 - it works without any changes in settings. Could you please advise what I should tune to start receiving e-mail alerts with FW 4.00.00.00 ? thank you. [/INST] There were a lot of changes made in 4.0 that may affect emails. I would start with number 18 in the Important notes section of the release notes. [URL] If that does not resolve the issue then you should review the lifecycle log and your mail server log to try to determine what exactly is failing. </s>