text
stringlengths
29
274k
<s>[INST] Looking at some SSD options and the Samsung 860dtc series are being advertised as "enterprise"I had a few clients looking at some refurb 420\620's with 720Perc (maybe it was 710)in any case has anyone heard anything about these drives?960gb, 1920gb DataCentre use. im lookin to throw a couple 1920 as Raid1 on a esx box for a few 25-35 sites hosting DC\Exchange. Raid1 to simply provide me less downtime if one fails. I know how raid works and that the SSD will be used. [/INST] Let me clarify, as well as correct myself. The DTC do appear to be the data center versions, where I mistook as EVO's when referring to laptops and desktops. I am not showing the drive listed, so it isn't seen as supported. Now with that being said, it doesn't mean offhand that it won't work, but simply that it hasn't been tested on the server. So we can't say definitively if it will work or not. It would be based solely on trial and error, but we couldn't attest to the functionality of the drive. </s>
<s>[INST] I am using the awssdk.s3 library for .Net Core to connect to ECS. This works in every scenario I have tried except for one. When I call the CompleteMultipartUploadAsync method, if fails every time. I know I am using it right, first initiating the multipart upload and then uploading a couple of parts before finally trying to complete it. Everything leading up to CompleteMultipartUploadAsync works, even the call I make to AbortMultipartUploadAsync after catching the exception. The ErrorCode of the exception is "InvalidRequest". Is CompleteMultipartUploadAsync supported in ECS? Thank you. [/INST] I found the answer. I did not know about etags. Once I included the etags in the complete request, it worked. </s>
<s>[INST] Got a T410 with a PERC6i, and I'd like to put a T410 in there. Anyone know the part number for the compatible one, and for the SAS and battery cables? Thanks! [/INST] Hello There are several variations of the H700 adapter that are compatible with the T410. Here is the part number for the 512MB H700A without non-volatile cache: J9MR2 Please keep in mind that there are several part numbers for the same part, this is just one of them. We may change the part number if anything about the card changes. If the shipping firmware, packaging material, stickers, or anything else changes we may create a new part number. You can find more information about the controller in the manual. [URL] There are too many possible cables. I'm not going to list all of the cables. If you provide information about your drive configuration then myself or someone else may be able to provide the cable part numbers for your configuration. Thanks </s>
<s>[INST] hi all.. we have the first installation of a dd 9300 ha since we don-t have any experience we need info like > how many ip we needs or ask to customer to provide ? cable configuration ? how does it works ha in data domain ? how to configure it ? starting from what code we can configure it ? or what code ddos do you suggest ? many thanks regards Giacomo cester [/INST] Hello Giacomo cester, Here is the install guide for your DD9300 that has what is needed for the install. [URL] Please let us know if you have any other questions. </s>
<s>[INST] Il nostro server -Service tag: { { {Svc Tag removed by Moderator / Tag Svc rimosso dal moderatore }}}- segnala il seguente problema: Fault detected on drive 1 in disk drive bay 1 Cosa dobbimo fare per risolverlo ? Grazie [/INST] [IMAGE] </s>
<s>[INST] We use an EQL PS6100 array for our VDI environment. The issue is it is taking up a lot of space even after I deleted the VDI's. How do I reclaim this space in the group management? [/INST] Hello, The array on its own is unable to reclaim space. This is because like all block storage the array is unaware of files or filesystems. The OS tells the storage WRITE data at LBA X or READ data at LBA X. Only the OS via an allocation table knows what LBAs are used or free. There are SCSI commands to tell storage that blocks are free. The UNMAP LBA X command must come from the OS. So it is entirely dependent on the OS and filesystem to send these UNMAP commands. Some OS/Filesystems have software to do this. E.g. VMware VMFS has the ESXCLI command that will attempt to reclaim blocks. Windows W2K12+ uses the defrag program to also send UNMAP commands. On the EQL side the only caveat is the the volume cannot be using EQL replication. Either SYNC or ASYNC, if so then UNMAP is not supported. You would have to DISABLE replication, not PAUSE, run UNMAP then start replication over for that volume. Regards, Don </s>
<s>[INST] Since upgrading multiple vxrails to 4.5.227 in different locations we're getting frequent temperature alerts. When viewing the hardware tab the alerts vs what's being reported as the temperature doesn't match and often clears if I update sensors in the hardware tab. These vxrails weren't getting temperature alerts before the upgrade when they were on 4.0. Are there any existing issues with this? [/INST] Check out: [URL] This is due to an ESXi CIM bug where non-existent hardware (NVMe etc) sensor readings are "0" where 0 in this instance is detected as a cause for alarm in vSphere. The fix will be included in a future VxRail update, in the meantime to workaround you can disable the alarm in VC </s>
<s>[INST] R630 with IDRAC 2.30.30.30, bios 2.0.1, upgrade firmware to 2.60.60.60, then reboot hangup when "Loading BIOS Drivers...", and try many times with the same error. downgrade IDRAC to 2.30.30.30, still hangup. try to reset idrac , still the same. [IMAGE]hangup [/INST] Remove and reapply server input power£¬ then everything is ok£¬ Thanks very much. </s>
<s>[INST] Just wondering has anyone seen this with rp4vm 5 .2.P2 It¡¯s a fresh install. After a failed upgrade... But the consistency group icons are unavailable for selection at one site, . All CG operations are available from second site vcs03.. [IMAGE] Debug to date : Reinstalled the plugin Login with admin[NAME].local Rebuilt the CG Reboot¡¯s /vc/rp/host Failed over the CG to see if was local/remote related [/INST] So the plugin must not have loaded correctly..[IMAGE] Even though it was showing enabled and correct in the /MOB, and updated from Help, the option to upgrade recover point for vm's option was still available from the help tab. [IMAGE] Cheers Idan for you time.. </s>
<s>[INST] We recently acquired a PowerVault ME4024, with a mix of flash and 10k drives. We bought some SSDs to use them as storage and some (2x480GB) to create a SSD Cache. I have created a read-cache disk group with these two drives but I'm not sure I have configured them correctly: Pool A Pool B I created the disks groups and some volumes, but I want to be sure the 10K disk groups are being optimized by the read-cache disk group. Can you help me? [/INST] Hello Markman12-, The following is found on page 88 of the administrator guide. [URL] ¡°A read-cache disk group is a special type of a virtual disk group that is used to cache virtual pages to improve read performance. Read cache does not add to the overall capacity of the pool to which it has been added. You can add or remove it from the pool without any adverse effect on the volumes and their data for the pool, other than to impact the read-access performance. If your system uses SSDs, you can create read-cache disk groups for virtual pools if you do not have any virtual disk groups for the pool that are comprised of SSDs. Virtual pools cannot contain both read-cache and a Performance tier. Only a single read-cache disk group may exist within a pool. Increasing the size of read cache within a pool requires the user to remove the read-cache disk group, and then re-add a larger read-cache disk group. It is possible to have a read-cache disk group that consists of one or two disks with a non-fault tolerant RAID level. ¡° Based on the way you have configured your disk groups & pools your setup follows the setup for SSD read-cache. Please let us know if you have any other questions. </s>
<s>[INST] Hello I have a up linked DELL 7048P from Nexus 3132Q and I can't bring the links up after upgraded to the latest firmware on 7048P trough openmanage switch administrator. Before that the 10G links was working I followed the instruction from dell support carefully. ([URL] It is my first time I used DELL PowerConnect switch on my setup and all of my network equipment is cisco I have a few X1052's but seems they don't have any issues connecting with cisco as I believe Power connect shouldn't have too because the link was up before I don't know what exactly happen after the upgrade I had no errors during the upgrade Any suggestions? console(config-if-Gi1/0/45)#speed 10000Selected option is not supported on this interface.console(config-if-Gi1/0/45)#interface tengigabitethernet ? / / Enter interface in interface format. console(config-if-Gi1/0/45)#interface tengigabitethernet 1/0/45 An invalid interface has been used for this function. [/INST] The combo ports are still 1G only the rear expansion modules are 10G. Page 7 [URL] </s>
<s>[INST] Hi all Rather a quick one. In the old days there was an agent I used to install on Windows Server for better integration with EMC VNX. Is there a similar one for EMC Unity as well or is it not needed to install any software? Cheers and thanks a lot [/INST] Unity does not use the EMC Host Agent for hosts. glen </s>
<s>[INST] Hi all, Recently I've been working on installing my Poweredge r610 server and I'm getting an error. I've been working on this for hours now but I can't figure out whats causing this. The error I'm getting says "Fault detected in Drive 2" (same error for drive 3). I've tried 2 different disks and also tried placing them in other slots. These drives are both very new and have pretty much not been used before placing them in the server. I've scanned them with a bunch of tools which both show no errors. When booting the server the orange flashing ligths become green. It also says it is loading all 3 virtual drives. My raid config utility shows no errors either. The drives are even detected by windows, useable and fast. While booting the lights start flashing orange again. I can still use them without any errors. Could anyone explain why I'm getting these errors? Thanks in advance! Please note that I am not a system administrator. I'm a developer who likes working with servers at home ?? [/INST] Try updating the system, but the problem is the "two Samsung SSD's and two HDD's I had lying around" ... the controller has very specific requirements of the drives, so you can't expect just any old drive will work. They may, but they may not. The messages will not disappear entirely. The best you can do with those drives is get them to show as online BUT with a non-critical flag/message regarding the drives' state. They simply don't know how to communicate their status to the controller in the way the controller expects. </s>
<s>[INST] I have a PowerVault 124T autoloader and I cannot log into through the web console & from the device front panel. What is the default username and password for the 124T through the web console & front panel login? [/INST] Hello AntoBen, The default username for the Remote Management Unit is admin. The default password is password. The front panel is not set with a password by default. When you try to login using the web utility what is the numbers in the ** **? Here is an example **12345**. Please let us know if you have any other questions. </s>
<s>[INST] I am really struggling to troubleshoot this problem because it just doesn't seem to make any sense. After deploying the OVA and adding my Isilon cluster as a source, the Access Zones are recognised and the SMB share is mounted on the Isilon Search appliance. I can browse the files and even read the contents, but the Index never populates because the Scan jobs shows up as failed. Looking at the logs under /usr/local/search/log I see the following: ==> search-adminapi-stdout-issearchvm.log <== Access zones of Source server isilon.example.com: [{:zone_id=>1, :zone_name=>"System", :system=>true, :zone_path=>"/ifs"}, [...] {:zone_id=>15 [...]}] *******before api source create get_source_by_field_value with query json: {"from":0,"size":999,"query":{"bool":{"must_not":null,"must":{"term":{"general.name":"ISILON"}}}},"sort":[{"general.name":{"order":"asc","mode":"min"}}]} get_source_by_field_value with query json: {"from":0,"size":999,"query":{"bool":{"must_not":null,"must":{"term":{"general.address":"isilon.example.com"}}}},"sort":[{"general.name":{"order":"asc","mode":"min"}}]} ******in get_source_by_id, id:0007430a01a2b8d41d52c91d2ff48784fd9a mount test on share path //isilon.example.com/zinc$ success ******after audit setting Access zones of Source server isilon.example.com: [{:zone_id=>1, :zone_name=>"System", :system=>true, :zone_path=>"/ifs"}, [...] {:zone_id=>15 [...]}] ******before add source ******in add source ******add source response: {"_index"=>"system", "_type"=>"source", "_id"=>"0007430a01a2b8d41d52c91d2ff48784fd9a", "_version"=>1, "_shards"=>{"total"=>1, "successful"=>1, "failed"=>0}, "created"=>true} ******aftere add source *******after api source create create audit response : {:code=>201, :body=>{"_index"=>"system", "_type"=>"audit", "_id"=>"AWb1Kbg5RkV7iPXNHXWK", "_version"=>1, "_shards"=>{"total"=>1, "successful"=>1, "failed"=>0}, "created"=>true}, :token=>"[..]"} Get content index info for app isilon success Creating index ISILON in app isilon Create index ISILON in app isilon success set_index_user_roles response: {:code=>200, :body=>{"message"=>"ok"}, :token=>"[...]"} create audit response : {:code=>201, :body=>{"_index"=>"system", "_type"=>"audit", "_id"=>"AWb1Kbm7RkV7iPXNHXWL", "_version"=>1, "_shards"=>{"total"=>1, "successful"=>1, "failed"=>0}, "created"=>true}, :token=>"[...]"} Create workitem request: {"general":{"category":"job","type":"add_src","subtype":null,"platform":null,"feature":null,"name":"ISILON","description":"activity for source ISILON","source":["0007430a01a2b8d41d52c91d2ff48784fd9a"],"index":["isilon"],"node":{"target":"_all"},"priority":8,"stoptime":"5000-01-01T00:00:00.000Z","status":"pending","heartbeat":"2018-11-08T21:10:44.482Z","createdtime":"2018-11-08T21:10:44.482Z","modifiedtime":"2018-11-08T21:10:44.482Z"},"owner":{"modifiedby":{"id":"31393137323739382d373733382d313033382d393838332d303964373839336435663739","name":"admin","directory":"DefaultOpenLDAP","dn":"cn=admin,ou=People,dc=example,dc=com"},"createdby":{"id":"31393137323739382d373733382d313033382d393838332d303964373839336435663739","name":"admin","directory":"DefaultOpenLDAP","dn":"cn=admin,ou=People,dc=example,dc=com"}},"schedule":{},"config":null} Create workitem response: {:code=>201, :body=>{"_index"=>"system", "_type"=>"workitem", "_id"=>"AWb1KboWRkV7iPXNHXWM", "_version"=>1, "_shards"=>{"total"=>1, "successful"=>1, "failed"=>0}, "created"=>true}, :token=>"[...]"} create audit response : {:code=>201, :body=>{"_index"=>"system", "_type"=>"audit", "_id"=>"AWb1KbpERkV7iPXNHXWN", "_version"=>1, "_shards"=>{"total"=>1, "successful"=>1, "failed"=>0}, "created"=>true}, :token=>"[...]"} Isilon version is: 8.1.0.4. Protection policy of Source server isilon.example.com: +2d:1n inode mirror count is: 3 inode total is : 747709955.0 Total inode count is: 747709955.0, total objects count is: 241196760 And in the worker log: ==> search-isilon-worker-issearchvm.log <== 181|P 1|T [Thread-15]|2018-11-09 09:11:12,543|SourceAddHandler::mountShare|INFO|mount: /mnt/isi/ISILON-ISILON-0007430a01a2b8d41d52c91d2ff48784fd9a/ifs => //isilon.example.com/zinc$ |SourceAddHandler.java(196)|Job Id: AWb1KboWRkV7iPXNHXWM; issearchvm 182|P 1|T [Thread-15]|2018-11-09 09:11:12,551|BaseProvider::declaimSource|INFO|[task source-DEclaim] need=false,DEclaimed=true,max=-1,source-id=0007430a01a2b8d41d52c91d2ff48784fd9a,task-id=AWb1KhYLRkV7iPXNHXWO |BaseProvider.java(633)|Job Id: AWb1KboWRkV7iPXNHXWM; issearchvm [...] 191|P 1|T [Thread-9]|2018-11-09 09:11:12,794|MonitorWorkerHandler::refreshSource|INFO|Get the source info for id: 0007430a01a2b8d41d52c91d2ff48784fd9a |MonitorWorkerHandler.java(133)|Job Id: AWbwtHE2-2X-a4Sc2mGm; issearchvm 192|P 1|T [Thread-9]|2018-11-09 09:11:12,845|MonitorWorkerHandler::refreshSource|INFO|Get index name: isilon |MonitorWorkerHandler.java(139)|Job Id: AWbwtHE2-2X-a4Sc2mGm; issearchvm 193|P 1|T [Thread-9]|2018-11-09 09:11:12,869|MonitorWorkerHandler::refreshSource|INFO|Get isilon server info: address: isilon.example.com, port: 8080, user: zinc |MonitorWorkerHandler.java(145)|Job Id: AWbwtHE2-2X-a4Sc2mGm; issearchvm [...] 812|P 1|T [Thread-9]|2018-11-09 09:12:35,668|IsilonAuth::createSessionAuthHeaders|INFO|[cookie][https:// :8080]: [isisessid=3d7dfe4a-dc0d-4453-97ea-f9224ff93cd2]=>[isisessid=8f89ea1b-6984-4c53-a585-5254c8a0121f] |IsilonAuth.java(121)|Job Id: AWbwtHE2-2X-a4Sc2mGm; issearchvm 813|P 1|T [Thread-9]|2018-11-09 09:12:35,670|RestClient::doCommon|WARNING|(1/2) [401] [1ms] [N/A] [GET],[https:// body=[] resp-code=[401] resp-body=[{"errors":[{"message":"authorization required"}]}] |RestClient.java(674)|Job Id: AWbwtHE2-2X-a4Sc2mGm; issearchvm 814|P 1|T [Thread-9]|2018-11-09 09:12:35,670|MonitorWorkerHandler::getItemAttribute|WARNING|Cannot logon to isilon server isilon.example.com with username zinc password ********, will refresh source and have another try |MonitorWorkerHandler.java(246)|Job Id: AWbwtHE2-2X-a4Sc2mGm; issearchvm Which makes no sense because I can definitely login to the Isilon with the user and password I created, as well as fetching the JSON response from the API using curl: curl 'https:// :8080/namespace/ifs/SkypeShare/2-BackupService-11/BackupStore/TaskAssignment/BackupTask/BackupTask.txt?metadata' -H 'Connection: keep-alive' -H 'Pragma: no-cache' -H 'Cache-Control: no-cache' -H 'Authorization: Basic [TOKEN]' -H 'Upgrade-Insecure-Requests: 1' -H 'User-Agent: Mozilla/5.0 (X11; Linux x86_64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/70.0.3538.77 Safari/537.36' -H 'DNT: 1' -H 'Accept: text/html,application/xhtml+xml,application/xml;q=0.9,image/webp,image/apng,*/*;q=0.8' -H 'Accept-Encoding: gzip, deflate, br' -H 'Accept-Language: en-NZ,en;q=0.9,en-GB;q=0.8,en-US;q=0.7,fr;q=0.6,es;q=0.5' --compressed --insecure { "attrs" : [ { "name" : "is_hidden", "value" : false }, { "name" : "size", "value" : 40 }, { "name" : "block_size", "value" : 8192 }, [...] The permissions for the zinc user in the Isilon source are exactly as the Installation docs describe. What could be missing here? Also, my sincere apologies for tagging you directly. I don't know exactly where to post this, so I tagged you because you posted about Search before (based on the (few) results I found). dfelt JamesTMorton [/INST] Hello EBurqueno, I am sorry to say but Zinc is a dead product for searching on Isilon clusters. Not sure where you got the software, but at this time the tool to use would be ClarityNow! as a search tool for Isilon. I see based on what you posted that you have OneFS 8.1.0.4 which is considerably newer than the last version of OneFS that Zinc was built to work with. I would love to help you with this, but shortly after I started working with Zinc they made the decision to end the project and not move forward leaving it to other open source 3rd party products and ClarityNow! You can check out more about ClarityNow at [URL] site. Thank you, David Felt </s>
<s>[INST] I have a question regarding installing WS 2016 to R710 and DELL EMC Lifecycle Controller OS Driver Pack 17.12.00 that was published in late 2018. May I ask if the driver pack should be installed after installing OS or during? Currently, my purpose is to upgrading Windows Server 2008 R2 on R710 to WS 2016. Actually, I may have to clean-install the OS. I know Dell does not support WS 2016 for the machine, and Lfecycle controller can't be used to install the OS until now. But late this year, Dell published EMC Lifecycle Controller OS Driver Pack 17.12.00 that supports R710 and WS 2016. Thus, I wonder how to use the driver pack for the OS installation. [/INST] For future reference, I got the answer by finding following statement in Driverpack_readme.txt in the DVD. </s>
<s>[INST] what is difference between stats keys node.clientstats.connected.nfs node.clientstats.active.nfs [/INST] castleknock Connected connections are total connections (idle and active). Active connections are the connections with I/O. </s>
<s>[INST] Hi All Would it be bad practice to add an external DNS server address to a top of rack switch which provides a route to the outgoing firewall as well as routing the internal traffic? Thanks Eric [/INST] Hi, That should be fine, as long as there is a firewall or router between the switch and the internet. </s>
<s>[INST] Can EMC Smarts receive SNMP INFORM notifications? If so, does EMC Smarts acknowledge receipt of the INFORM? I've searching all over and have not found any info to even suggest the answer to this one way or another, thanks for any help you can provide! [/INST] Hi Sean, Sorry for the delay in response. Currently Smarts does not support informs on SNMP v2 only SNMP v3. I hope this answers your question. Please let us know if you have any further questions. Thank you, Kolter </s>
<s>[INST] We have a PowerEdge R710 where one drive went missing and another went failed in a RAID 5 configuration. Are we going to be able to swap out the missing drive and have it rebuild with the other drive being failed? What is the best way to handle this scenario? [/INST] Hello RAID 5 cannot recover from two failed drives. If you have important data that is not backed up then you should contact a data recovery company. You will need to create a new virtual disk. You may be able to re-seat that last failed drive and force it online. If you are able to do that and the virtual disk comes back up then the data will either be accessible or the disk will be seen as blank and cause the controller to delete the other disks to match. [URL] Thanks </s>
<s>[INST] Hi folks, I am following the Quick Start Guide on [URL] deploy ECS CE 3.2.2.0 (single node) on CentoOS 7. The bootstrap ran fine but the install is failing as below on "step1" with 'module' object has no attribute 'HTTPError'. TASK [common_deploy : Common | Create a data container for ECS configuration control] ****************************************************************************************************************************************************************************************** An exception occurred during task execution. To see the full traceback, use -vvv. The error was: AttributeError: 'module' object has no attribute 'HTTPError' fatal: [192.168.100.189]: FAILED! => {"changed": false, "failed": true, "module_stderr": "Traceback (most recent call last):\n File \"/tmp/ansible_4FOhhl/ansible_module_docker.py\", line 526, in \n import docker.client\n File \"/usr/lib/python2.7/site-packages/docker/__init__.py\", line 6, in \n from .client import Client, AutoVersionClient, from_env # flake8: noqa\n File \"/usr/lib/python2.7/site-packages/docker/client.py\", line 11, in \n from . import api\n File \"/usr/lib/python2.7/site-packages/docker/api/__init__.py\", line 2, in \n from .build import BuildApiMixin\n File \"/usr/lib/python2.7/site-packages/docker/api/build.py\", line 7, in \n from .. import errors\n File \"/usr/lib/python2.7/site-packages/docker/errors.py\", line 4, in \n c lass APIError(requests.exceptions.HTTPError):\nAttributeError: 'module' object has no attribute 'HTTPError'\n", "module_stdout": "", "msg": "MODULE FAILURE", "rc": 1} PLAY RECAP ********************************************************************************************************************************************************************************************************************************************************************* 192.168.100.189 : ok=19 changed=15 unreachable=0 failed=1 Playbook run took 0 days, 0 hours, 0 minutes, 19 seconds Operation failed. Running "step1" a 2nd time fails as the ECS disk is already partitioned, however when I re-format the drive and re-run "step1" again I hot the same error-> APIError(requests.exceptions.HTTPError):\nAttributeError: 'module' object has no attribute 'HTTPError'\n Has anyone seen this behaviour? Message was edited by: micksul [/INST] The issue was that the obj docker container IP range matched the network I used to deploy ECS. I performed a workaround and ECS CE is up and running. </s>
<s>[INST] membist failure the following dimm has been disabled a1 and a4 is what the post test is prompting is a brand new machine and having this issue. tried unplugging until no power was stored it had gone away but then the issue resurfaced bios is up to date any and all suggestions would be appreciated for this newb. [/INST] Hello You probably have a faulty memory module. When a module fails, memory that is dependent on that module will be disabled. You can run diagnostics, review logs, and move memory around to troubleshoot memory issues. You can find more information in the documentation on the system support page. [URL] Thanks </s>
<s>[INST] Can a MD3260 or MD3260i be converted to a MD3060e? Is the only difference between a MD3260/MD3260i and a MD3060e the controllers? So basically I have a MD3260i/MD3060e setup that will require expansion and I have some unused MD3260 and a MD3260i boxes that hopefully could be used for expanding my setup. I guess I cannot daisy chain a MD3260 to a MD3260i (or maybe I can?) so I was thinking about purchasing some MD3060e controllers and put them in one of my unused MD3260 box. Also I know that I will need a license to upgrade my 120 disks setup to a 180 disks setup so does anyone know how much this premium feature license cost? [/INST] Hello casfr, You can us an MD3260i & convert it to a MD3060e. Now your MD3260i will not be supported as an MD3060e if there is an issue that happens. You will need to reset your MD3260i back to factory settings. You will also need to get some MD3060e EMM¡¯s & will need to make sure that all EMM¡¯s are using the same firmware as your other MD3060e. Premium features license can vary from customer to customer. It is best to contact your sales rep to see what your cost would be. Please let us know if you have any other questions. </s>
<s>[INST] Hi I can¢¥t find any information about smb/cifs version on Data domain 6300 and dd os 6.1.2.10 The only information I can find is about smbv2, how about smbv3 support? [/INST] I got information from support: SMB2.0 and SMB2.1 supported SMB3 support is planned for next year (No ETA) </s>
<s>[INST] Hey folks, My CMC is behaving a little oddly. We've recently reconfigured switches in one of our M1000e, and were making some minor changes just to apply labels to ports. Mid session, the CMC session kicked the engineer out, and we now can't get into ANY of the six M8024-K switches in the unit. [IMAGE] Exciting screenshot. Is there anything I can do remotely that will help, or do i need to send someone to site to reseat switches? Thanks! Max [/INST] In that case reseating the switches is probably the best option. You could also try failing over to the other CMC if you have two. </s>
<s>[INST] System: PowerEdge R910, 11GOperating System: RHEL/CentOS 7Issue: Deployment Toolkit v6.0.1 missing libstdc++ and libxml2 packagesBIOS and iDRAC firmware upgrades are being done remotely via iDRAC6 Enterprise. This is an 11G server, so the firmware is no longer included as an update using the Lifecyle Controller. Per article:[URL]#2I downloaded the Deployment Toolkit for R910, and I'm mapping the "ISOLinux.iso" using the iDRAC6 virtual console's virtual media feature.The BIOS update to version 2.12.0 worked without problem. The iDRAC firmware update (version 2.85 to 2.90 using ESM_Firmware_9GJYW_LN32_2.90_A00.BIN) fails with the following error message:"The following packages are required for update package to run: compat-libstdc++-33.i686 libstdc++.i686 libxml2.i686"In my experience this type of error usually results from a 64-bit OS like RHEL/CentOS 7 attempting to run 32-bit software.Since I'm using the Deployment Toolkit on the ISO image mounted as virtual media, how do I resolve the dependencies? (The OS on the R910, and the machine I'm using to to perform the maintenance have the libstdc++ and libxml2 packages installed)This is an exclusively RHEL/CentOS environment, so I'm looking for a long-term maintenance solution NOT involving MS Windows. Or is there an alternative update method for the iDRAC firmware that can be done remotely from a machine running RHEL/CentOS 7? [/INST] We have 100% Linux environment - not a single server, or workstation running windows. Since Dell supports numerous Linux distros, it would be useful to get some Linux-specific hardware support.For Linux users: None of the toolkit software is needed for the iDRAC firmware update.SOLUTION:1. On any Linux client machine, browse to the associated dell.com/support for the service tag/server model.2. I was unable to get the iDRAC6 to accept the firmware image for RHEL 7/CentOS 7 ("ESM_Firmware_9GJYW_LN32_2.90_A00.BIN") using the iDRAC web gui > iDRAC > upgrade > upload feature. Alternatively, I extracted the firmware image from the Windows Server 2003 archive (step 3). Yes,3. Select OS: Windows 2003 server and download "Dell iDRAC Monolithic Release 2.90", file "ESM_Firmware_9GJYW_WN32_2.90_A00.EXE".4. On Linux client machine, use any archive management software that can handle Windows archive EXE file to extract files. Using the "unzip" program via command line:cd ~/Downloads/mkdir idrac6_firmware_2.90cd idrac6_firmware_2.90/unzip ESM_Firmware_9GJYW_WN32_2.90_A00.EXE*** NOTE: The only relevant file is payload > "firmimg.d6" 5. I had numerous failures uploading and installing the firmware image using the iDRAC6 web GUI, so I recommend rebooting both the client machine with fresh browser session, and the iDRAC. To avoid a factory reset of the iDRAC and lose settigs, a soft-reset can be easily via secure shelle:Client machine's command line:ssh yourLoginName[NAME]:/admin1-> racadm racreset6. Give the iDRAC a 5 minutes to reboot. On your Linux client machine use a browser to log into the iDRAC through the web gui.7. Browse to iDRAC Settings > Update > click Browse > select ~/Downloads/idrac_firmware_2.90/payload/firmimg.d6 (or wherever the firmware image was extracted).8. "Upload (Step 1 of 3) > Click upload. Do NOT browse off of the iDRAC upload page.9. If the upload is successful you will see "Status (2 of 3)", showing current version number and new version number. If it fails/hangs try rebooting your client and browser session.10. Click "next" button11. The installation of the firmware should start and show "Updating (Step 3 of 3)" and periodically update the "status" box. Do NOT browse off of the iDRAC installation page. Mine took about 10 minutes and spent several minutes before jumping to each of 0%, 30%, 50%, 70%, 90% values. Let it run. If you see a spinning wheel, or a message like "The firmware is updating, try again later", start over at step 5.12. If the installation is successful, you will get a new message confirming it, and indicating that the current session is no longer valid. The iDRAC is automatically rebooting with the new firmware. Give it several minutes - mine took 5+ minutes. </s>
<s>[INST] I thought I would upgrade our Networker server to Solaris 11.4 and gst fails to start. All all works find with Solaris 11.3 but I get the server gst starts and shutdowns and I do not see any errors! I. 10/31 16:42:32. SQL Anywhere Network Server Version 12.0.1.3152 I. 10/31 16:42:32. OEM Authenticated Edition, licensed only for use with authenticated OEM applications. I. 10/31 16:42:32. I. 10/31 16:42:32. Copyright (c) 2001-2011, iAnywhere Solutions, Inc. I. 10/31 16:42:32. Portions copyright (c) 1988-2011, Sybase, Inc. All rights reserved. I. 10/31 16:42:32. Use of this software is governed by the Sybase License Agreement. I. 10/31 16:42:32. Refer to [URL] I. 10/31 16:42:32. I. 10/31 16:42:32. Connection limit (licensed seats): 500000 I. 10/31 16:42:32. Processors detected: 2 (containing 16 logical processors) I. 10/31 16:42:32. Maximum number of physical processors the server will use: 2 I. 10/31 16:42:32. This server is licensed to: I. 10/31 16:42:32. EMC I. 10/31 16:42:32. EMC I. 10/31 16:42:32. Running SunOS 5.11 11.4.2.3.0 on X86_64 I. 10/31 16:42:32. Server built for X86_64 processor architecture I. 10/31 16:42:32. 361028K of memory used for caching I. 10/31 16:42:32. Minimum cache size: 9664K, maximum cache size: 512000K I. 10/31 16:42:32. Using a maximum page size of 4096 bytes I. 10/31 16:42:32. Multiprogramming level: minimum:16, current:20, maximum:80 I. 10/31 16:42:32. Automatic tuning of multiprogramming level is enabled I. 10/31 16:42:32. Starting database "lgto_gst" (/var/lgto_gstdb/lgto_gst.db) at Wed Oct 31 2018 16:42 I. 10/31 16:42:32. Transaction log: lgto_gst.log I. 10/31 16:42:32. Starting checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:42 I. 10/31 16:42:32. Finished checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:42 I. 10/31 16:42:32. Database "lgto_gst" (lgto_gst.db) started at Wed Oct 31 2018 16:42 I. 10/31 16:42:32. This database is licensed for use with: I. 10/31 16:42:32. Application: GEMS I. 10/31 16:42:32. Company: Legato Systems, Inc. I. 10/31 16:42:32. Database server started at Wed Oct 31 2018 16:42 I. 10/31 16:42:32. Trying to start SharedMemory link ... I. 10/31 16:42:32. SharedMemory link started successfully I. 10/31 16:42:32. Trying to start TCPIP link ... I. 10/31 16:42:32. Starting on port 2638 I. 10/31 16:42:37. TCPIP link started successfully I. 10/31 16:42:37. Now accepting requests I. 10/31 16:42:46. Database server shutdown requested by DBSTOP I. 10/31 16:42:46. TCPIP listener on IP address (::):2638 is exiting I. 10/31 16:42:46. TCPIP listener on IP address 0.0.0.0:2638 is exiting I. 10/31 16:42:46. Starting checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:42 I. 10/31 16:42:46. Finished checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:42 I. 10/31 16:42:47. Database server stopped at Wed Oct 31 2018 16:42 I. 10/31 16:45:27. SQL Anywhere Network Server Version 12.0.1.3152 I. 10/31 16:45:27. OEM Authenticated Edition, licensed only for use with authenticated OEM applications. I. 10/31 16:45:27. I. 10/31 16:45:27. Copyright (c) 2001-2011, iAnywhere Solutions, Inc. I. 10/31 16:45:27. Portions copyright (c) 1988-2011, Sybase, Inc. All rights reserved. I. 10/31 16:45:27. Use of this software is governed by the Sybase License Agreement. I. 10/31 16:45:27. Refer to [URL] I. 10/31 16:45:27. I. 10/31 16:45:27. Connection limit (licensed seats): 500000 I. 10/31 16:45:27. Processors detected: 2 (containing 16 logical processors) I. 10/31 16:45:27. Maximum number of physical processors the server will use: 2 I. 10/31 16:45:27. This server is licensed to: I. 10/31 16:45:27. EMC I. 10/31 16:45:27. EMC I. 10/31 16:45:27. Running SunOS 5.11 11.4.2.3.0 on X86_64 I. 10/31 16:45:27. Server built for X86_64 processor architecture I. 10/31 16:45:27. 361028K of memory used for caching I. 10/31 16:45:27. Minimum cache size: 9664K, maximum cache size: 512000K I. 10/31 16:45:27. Using a maximum page size of 4096 bytes I. 10/31 16:45:27. Multiprogramming level: minimum:16, current:20, maximum:80 I. 10/31 16:45:27. Automatic tuning of multiprogramming level is enabled I. 10/31 16:45:27. Starting database "lgto_gst" (/var/lgto_gstdb/lgto_gst.db) at Wed Oct 31 2018 16:45 I. 10/31 16:45:27. Transaction log: lgto_gst.log I. 10/31 16:45:27. Starting checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:45 I. 10/31 16:45:27. Finished checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:45 I. 10/31 16:45:27. Database "lgto_gst" (lgto_gst.db) started at Wed Oct 31 2018 16:45 I. 10/31 16:45:27. This database is licensed for use with: I. 10/31 16:45:27. Application: GEMS I. 10/31 16:45:27. Company: Legato Systems, Inc. I. 10/31 16:45:27. Database server started at Wed Oct 31 2018 16:45 I. 10/31 16:45:27. Trying to start SharedMemory link ... I. 10/31 16:45:27. SharedMemory link started successfully I. 10/31 16:45:27. Trying to start TCPIP link ... I. 10/31 16:45:27. Starting on port 2638 I. 10/31 16:45:32. TCPIP link started successfully I. 10/31 16:45:32. Now accepting requests I. 10/31 16:45:41. Database server shutdown requested by DBSTOP I. 10/31 16:45:41. TCPIP listener on IP address (::):2638 is exiting I. 10/31 16:45:41. TCPIP listener on IP address 0.0.0.0:2638 is exiting I. 10/31 16:45:41. Starting checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:45 I. 10/31 16:45:41. Finished checkpoint of "lgto_gst" (lgto_gst.db) at Wed Oct 31 2018 16:45 I. 10/31 16:45:42. Database server stopped at Wed Oct 31 2018 16:45 I know I do not need GST to start, but I was unable to enable the Jukebox at the command prompt, so I need the GUI. Any ideas? [/INST] Got it working! It is the Apache httpd which is having problem. /opt/LGTOnmc/apache/bin/httpd is failing on a missing libucb.so.1 library. I could try to put in a newer version of httpd in, but for a quick fix I copied the old Solaris11.3 library to Solaris 11.4 # cp /Solaris11.3/usr/ucblib/amd64/libucb.so.1 /opt/LGTOnmc/apache/lib The /etc/init.d/gst started. Thanks Andrew </s>
<s>[INST] I asked this question last week, but need to dive a little deeper. I asked about zeroing out the data on the disks of a VNXe3300. I was pointed to a document containing commands to destroy the data and prepare the VNXe for decommission. However, I need to get down to the byte level on the disks and overwrite the data on the disks themselves. Is there an EMC tool that will do this? Thanks ! [/INST] Thank you very much. Where do I run this command from ? Thanks ! </s>
<s>[INST] Hi all, how can I find out the number of hours needed to write zeros into the storage below ? I will be using the method below . [URL] Model: EMC VNXe 3200 Disks: 3 x 200GB flash drive for fast cache 31 x 300GB 15K RPM SAS drives Model: EMC Data Domain 2200 Disk: 14TB raw capacity [/INST] I don't believe there is any way to estimate how long this will take. It could be hours, could be longer. Make sure you have deleted all objects off first, so that nothing is configured. glen </s>
<s>[INST] Hi all, I could really use some help and insight. The company I work for uses a 3rd party vendor for hosting our data. Unfortunately, trying to pry information from this vendor is like pulling teeth. We are experiencing an issue wherein the Access Date for the filesystem is always being changed. Our company deals in data preservation this poses a pretty big issue for us. With the information I have been able to grab a hold of, the vendor is using an FS8600 with a Linux OS. I have made inquiries if the NOATIME option can be turned on for the mounted drives. The response I have gotten is less than desirable that "Dell has built a proprietary OS that sits on top of the Linux Shell, and that there are a limited set of commands that are reserved for Dell Engineering team." Anyone happen to know anything about this Dell OS (I am not sure if the vendor is talking about Dell Storage Manager or Dell Storage Center OS) and the interaction with Linux and availability of options? Thank you, and I really appreciate any information! [/INST] Hello Maliceous, Likewise is part of the FS system. Please let us know if you have any other questions. </s>
<s>[INST] We have a Unity 500 Hybrid with a mixture of 2,5" and 3.5" disks and related DAE's. My question, does the order of the DAE's make a difference when racking and cabling or is this a "moot point" these days (3 x 2.5" DAE's and 3 x 3.5" DAE's)? Thanks [/INST] OK - look at page 63 in the manual. The first DAE that's connected to the DPE, you used cables from the DPE to the first DAE using the "A" port on the DAE - this is the "IN" port on the DAE. Port "B" is the "OUT" port to the next DAE in the chain to that DEA's "A" ports. You have two Backend (BE0 and BE1) SAS buses on the DPE, so balance the number of DEA's on the buses. BE0 connects to the DPE disks, so use BE1 to connect to the first DAE, then BE0 to the second DAE, then BE1 to the third DAE. Then you have two DAE's (one is the DPE) on BE0 and two on BE1. The order does not matter, but if you only have 1 meter cables you might have problems if you connected all the BE0 DAE's first, then tried to cable the BE1 bus to the fourth DAE - the 1 meter cable might not reach. It's B (out) to A (in). glen </s>
<s>[INST] System is out of warranty and a lab system, its working but i want to reload the image on it because some configuration won't let me delete it. I boot it up with serial cable attached, and hit ctrl-c and per "Backrev Array" solution it's supposed to do a Minisetup and reboot a few times. It never reboots it just sits at the "int13 - EXTENDED READ (4000)" and never goes further. I rebooted it manually myself and try to start the process again but I just get this... any ideas? ABCDabcdEFabcd << Stopping after POST >> GabcdefHabcdefIabcdefJabcdeKLabMabNabOabcPQRSTUVWabXYabZAABBCCabDDabcEEabcFFabcGGabcHHabcIIabJJabKKLLMMNNOOPPQQRRSSTTUUVVWWXX ************************************************************ * Extended POST Messages ************************************************************ INFORMATION: POST Start INFORMATION: MCU Operating mode changed from Linux to Clariion INFORMATION: PSB not present ************************************************************ EndTime: 10/28/2018 15:29:59 .... Storage System Failure - Contact your Service Representative ... ******* Enclosure: 0x0008000B : Added to Table Motherboard: 0x00130009 : Added to Table Memory: 0x00000001 DIMM 0: 0x00000001 DIMM 1: 0x00000001 DIMM 2: 0x00000001 Mezzanine: 0x00100007 I/O Module 0: 0x00000001 : Added to Table I/O Module 1: 0x00000001 : Added to Table Power Supply A: 0x000B0014 Power Supply B: 0x00000001 0x00130009: MCU 0540 0x00130009: CMDAPP 0504 0x00130009: CMDTABLE 0096 0x00130009: CMDBOOT 0002 0x00130009: PLX 0305 0x000B0014: PS FW 0027 Checksum valid Relocating Data Directory Boot Service (DDBS: Rev. 05.03)... DDBS: K10_REBOOT_DATA: Count = 1 DDBS: K10_REBOOT_DATA: State = 0 DDBS: K10_REBOOT_DATA: ForceDegradedMode = 0 DDBS: **** WARNING: SP rebooted unexpectedly before completing MiniSetup on the Utility Partition. DDBS: MDDE (Rev 600) on disk 1 DDBS: MDDE (Rev 600) on disk 3 DDBS: MDB read from both disks. DDBS: Chassis and disk WWN seeds match. DDBS: First disk is valid for boot. DDBS: Second disk is valid for boot. Utility Partition image (0x0040000F) located at sector LBA 0x1453D802 Disk Set: 1 3 Total Sectors: 0x013BA000 Relative Sectors: 0x00000800 Calculated mirror drive geometry: Sectors: 63 Heads: 255 Cylinders: 1287 Capacity: 20686848 sectors Total Sectors: 0x013BA000 Relative Sectors: 0x00000800 Calculated mirror drive geometry: Sectors: 63 Heads: 255 Cylinders: 1287 Capacity: 20686848 sectors Stopping USB UHCI Controller... Stopping USB UHCI Controller... EndTime: 10/28/2018 15:33:37 int13 - RESET (1) int13 - CHECK EXTENSIONS PRESENT (3) int13 - CHECK EXTENSIONS PRESENT (5) int13 - GET DRIVE PARAMETERS (Extended) (6) int13 - EXTENDED READ (200) int13 - EXTENDED READ (400) int13 - EXTENDED READ (600) int13 - READ PARAMETERS (800) int13 - READ PARAMETERS (802) int13 - DRIVE TYPE (803) int13 - CHECK EXTENSIONS PRESENT (804) int13 - GET DRIVE PARAMETERS (Extended) (805) int13 - READ PARAMETERS (806) int13 - EXTENDED WRITE (846) int13 - EXTENDED WRITE (847) int13 - EXTENDED WRITE (848) int13 - READ PARAMETERS (964) int13 - DRIVE TYPE (965) int13 - CHECK EXTENSIONS PRESENT (966) int13 - GET DRIVE PARAMETERS (Extended) (967) int13 - READ PARAMETERS (968) int13 - EXTENDED WRITE (997) int13 - EXTENDED WRITE (998) int13 - EXTENDED WRITE (999) int13 - EXTENDED READ (1000) int13 - EXTENDED WRITE (1012) int13 - EXTENDED WRITE (1013) int13 - EXTENDED WRITE (1014) int13 - EXTENDED READ (1200) int13 - EXTENDED READ (1400) int13 - EXTENDED READ (1600) int13 - EXTENDED READ (1800) int13 - EXTENDED READ (2000) int13 - EXTENDED READ (2200) int13 - EXTENDED READ (2400) int13 - EXTENDED READ (2600) int13 - EXTENDED READ (2800) int13 - EXTENDED READ (3000) int13 - EXTENDED READ (3200) int13 - EXTENDED READ (3400) int13 - EXTENDED READ (3600) int13 - EXTENDED READ (3800) int13 - EXTENDED READ (4000) It doesn't seem to ever go past this... so I cannot move on to the next steps in the solution. any help or experience with this would be much appreciated! -M [/INST] The system is reimaged... SPa boots up fine now. In the end I needed to use SPb to run the utility partition to do the reimage. </s>
<s>[INST] Hi, Trying to setup vrpa cluster on esxi 6.7U1, installation ends up with an error: could not create virtual repository. And when I check logs, i see in server.log: 2018-10-27 18:01:22,237 [CommandWorker-13] (BaseAction.java:42) ERROR - CreateRecoverPointDeviceAction Failed. com.emc.recoverpoint.connectors.actions.infra.ActionFailedException: API Version <6.7.1> is not a number, cannot get virtual disk type Maybe there are any updates comming to support newest ESXi? [/INST] Yes it seems to be Vcenter issue. I can reproduce problem with 6.7.0U1, while 6.7.0d works fine. </s>
<s>[INST] We have a batch of PER 13G servers which have been upgraded from ESXi 6.5u1 to ESXi 6.7 GA and ever since, OMSA agent is not working on these ESXi servers, and we cannot manage them with OMIVV or OMSA Managed Node anymore. It is stated here: <ADMIN NOTE: Broken link has been removed from this post by Dell> that ESXi 6.7 is supported with OMSA 9.1.1, however, the only supported server models are PER840 and PER940xa. A few days ago, Dell EMC Systems Management Tools (containing OMSA agent) v.9.2.0 have been published for 13G servers and ESXi 6.7 is listed as supported, however, no packages for any ESXi version can be found inside the bundle. Dell VUM repository ([URL] still does not return any OMSA packages for ESXi 6.7 when requested through VUM. ESXi 6.7 GA is out for more than 6 months, which should be more than enough time to release an OMSA agent that supports this ESXi version for a broader range of Dell PER servers. When will the OMSA agent that supports ESXi 6.7 and 13G servers be released either through VUM, or as a VIB (zip) package ? [/INST] Well it seems like someone in Dell has heard my call for help :) Here it is: [URL] </s>
<s>[INST] I bought a used C6220 II system board 0083N0 which has BIOS 3.2.11 from 2014. I would like to update that, but all current BIOS for C6220/C8220 series are 2.x. I haven't been able to figure out what that old 3.2.11 is and if it is safe to update to current 2.9 or similar? [/INST] Hello That is not a C6220/II board. It is a system board for one of our Data Center Solutions products that are based on the Cloud line of products. The DCS line of servers are custom solutions that may use hardware, BIOS, or firmware that is specific to the customer the solution was created. Any custom BIOS or firmware created for a customer is only available to that customer. I would not use that system board in a normal C6220 II. If you are not having any issues then I would not change the BIOS. Thanks </s>
<s>[INST] Hello, Our T310 server with raid 5 running on perc h700 started displaying some errors recently. It is just 2 months our of warranty and not allowed to be extended. I wish we could. I suspect a drive is starting to go bad. I wondered if I someone could look over the info below and confirm my thoughts. And to also recommend the next course of action. The primary concerning errors I will post first, then secondary errors that might also be a concern, then system, controller and drive info. Sorry if the formatting is less than ideal. Please let me know if you need anything else. Thank you very much for your help. ---------- most concerning errors 2095 Sun Oct 21 21:11:57 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 3 Sense code: 11 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02095 Sun Oct 21 21:11:57 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02095 Sun Oct 21 21:11:57 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 3 Sense code: 11 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02266 Sun Oct 21 21:11:57 2018 Storage Service Controller log file entry: Physical Disk 0:0:0 Controller 0, Connector 02095 Sun Oct 21 21:11:54 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 0 --------------- other errors that are also slightly concerning 2095 Sun Oct 21 21:11:57 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 3 Sense code: 11 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02095 Sun Oct 21 21:11:57 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02095 Sun Oct 21 21:11:57 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 3 Sense code: 11 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02266 Sun Oct 21 21:11:57 2018 Storage Service Controller log file entry: Physical Disk 0:0:0 Controller 0, Connector 02095 Sun Oct 21 21:11:54 2018 Storage Service Unexpected sense. SCSI sense data: Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:0:0 Controller 0, Connector 02243 Sat Oct 20 04:24:14 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Oct 20 03:28:07 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Oct 13 04:27:07 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Oct 13 03:27:57 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2358 Fri Oct 12 16:54:20 2018 Storage Service The battery charge cycle is complete.: Battery 0 Controller 02199 Fri Oct 12 13:28:30 2018 Storage Service The virtual disk cache policy has changed.: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2189 Fri Oct 12 13:28:29 2018 Storage Service The controller write policy has been changed to Write Back.: Battery 0 Controller 02247 Fri Oct 12 12:41:54 2018 Storage Service The controller battery is charging.: Battery 0 Controller 02177 Fri Oct 12 12:41:40 2018 Storage Service The controller battery Learn cycle has completed.: Battery 0 Controller 02188 Fri Oct 12 11:49:10 2018 Storage Service The controller write policy has been changed to Write Through.: Battery 0 Controller 02199 Fri Oct 12 11:49:10 2018 Storage Service The virtual disk cache policy has changed.: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2176 Fri Oct 12 10:18:05 2018 Storage Service The controller battery Learn cycle has started.: Battery 0 Controller 02180 Mon Oct 08 09:46:30 2018 Storage Service The controller battery Learn cycle will start in 4 days.: Battery 0 Controller 02243 Sat Oct 06 04:23:47 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Oct 06 03:27:50 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Sep 29 04:26:51 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Sep 29 03:27:43 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Sep 22 04:25:57 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Sep 22 03:27:35 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2358 Mon Sep 17 11:35:22 2018 Storage Service The battery charge cycle is complete.: Battery 0 Controller 02334 Mon Sep 17 11:14:13 2018 Storage Service Controller event log: Unexpected sense: Encl PD 20 Path 5882b0b04b4bf400, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:12 2018 Storage Service Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:12 2018 Storage Service Controller event log: Battery started charging: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:12 2018 Storage Service Controller event log: Unexpected sense: Encl PD 20 Path 5882b0b04b4bf400, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:11 2018 Storage Service Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:11 2018 Storage Service Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:11 2018 Storage Service Controller event log: Time established as 09/17/18 11:09:52; (65 seconds since power on): Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:11 2018 Storage Service Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Firmware initialization started (PCI ID 0079/1000/1f16/1028): Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Battery Present: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Package version 12.10.7-0001: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Board Revision A04: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Adapter)2334 Mon Sep 17 11:14:10 2018 Storage Service Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Adapter)1000 Mon Sep 17 11:14:02 2018 Instrumentation Service Server Administrator starting1012 Mon Sep 17 11:14:02 2018 Instrumentation Service IPMI status Interface: OS1001 Mon Sep 17 11:14:02 2018 Instrumentation Service Server Administrator startup complete1008 Mon Sep 17 11:14:02 2018 Instrumentation Service Systems Management Data Manager Started2243 Sat Sep 15 04:27:15 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Sep 15 03:29:21 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2085 Thu Sep 13 16:50:27 2018 Storage Service Virtual disk Check Consistency completed: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2058 Thu Sep 13 16:01:54 2018 Storage Service Virtual disk Check Consistency started: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2243 Sat Sep 08 04:26:10 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Sep 08 03:29:14 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Sep 01 04:28:10 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Sep 01 03:29:08 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Aug 25 04:30:11 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Aug 25 03:29:01 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Aug 18 04:29:10 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Aug 18 03:28:50 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Aug 11 04:26:08 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Aug 11 03:28:44 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Aug 04 04:30:35 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Aug 04 03:28:35 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Jul 28 04:28:15 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Jul 28 03:28:30 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2243 Sat Jul 21 04:26:26 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Jul 21 03:28:24 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2358 Sat Jul 14 13:57:59 2018 Storage Service The battery charge cycle is complete.: Battery 0 Controller 02189 Sat Jul 14 10:32:10 2018 Storage Service The controller write policy has been changed to Write Back.: Battery 0 Controller 02199 Sat Jul 14 10:32:10 2018 Storage Service The virtual disk cache policy has changed.: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2247 Sat Jul 14 09:46:40 2018 Storage Service The controller battery is charging.: Battery 0 Controller 02177 Sat Jul 14 09:46:25 2018 Storage Service The controller battery Learn cycle has completed.: Battery 0 Controller 02188 Sat Jul 14 08:53:55 2018 Storage Service The controller write policy has been changed to Write Through.: Battery 0 Controller 02199 Sat Jul 14 08:53:55 2018 Storage Service The virtual disk cache policy has changed.: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2176 Sat Jul 14 07:22:36 2018 Storage Service The controller battery Learn cycle has started.: Battery 0 Controller 02243 Sat Jul 14 04:24:56 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Jul 14 03:28:14 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter)2085 Tue Jul 10 17:10:52 2018 Storage Service Virtual disk Check Consistency completed: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2058 Tue Jul 10 16:21:28 2018 Storage Service Virtual disk Check Consistency started: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Adapter)2180 Tue Jul 10 05:59:02 2018 Storage Service The controller battery Learn cycle will start in 4 days.: Battery 0 Controller 02243 Sat Jul 07 04:19:48 2018 Storage Service The PTRL Read has stopped.: Controller 0 (PERC H700 Adapter)2242 Sat Jul 07 03:28:08 2018 Storage Service The PTRL Read has started.: Controller 0 (PERC H700 Adapter) ------------------------ system info server t310 Status ID Name Slot ID State Firmware Version Storport Driver Version0 PERC H700 Adapter PCI Slot 1 Ready 12.10.7-0001 6.1.7601.18386Firmware Version 12.10.7-0001Driver Version 4.31.01.64Storport Driver Version 6.1.7601.18386 server 2008 r2 sp1 ID 0:0:0Status OKName Physical Disk 0:0:0State OnlinePower Status Spun UpBus Protocol SATAMedia HDDRevision MA08T10 PI Capable NoCertified YesCapacity 232.25GBUsed RAID Disk Space 232.25GBAvailable RAID Disk Space 0.00GBHot Spare NoVendor ID DELL(tm)Product ID ST3250310NSSerial No. 9SF18CHBPart Number TH0F420T2123398L001WA0Negotiated Speed 3.00 GbpsCapable Speed 3.00 GbpsSector Size 512BSAS Address 4433221107000000Non-RAID HDD Disk Cache Policy Not ApplicablePhysical Disk 0:0:1 Online Spun Up Available TasksBlinkUnblinkOffline ... Execute SATA HDD 02.03B05ID 0:0:1Status OKName Physical Disk 0:0:1State OnlinePower Status Spun UpBus Protocol SATAMedia HDDRevision 02.03B05T10 PI Capable NoCertified YesCapacity 232.25GBUsed RAID Disk Space 232.25GBAvailable RAID Disk Space 0.00GBHot Spare NoVendor ID DELL(tm)Product ID WDC WD2502ABYS-18B7A0Serial No. WD-WCAT1J281714Part Number TH0H962F1255216R036CA0Negotiated Speed 3.00 GbpsCapable Speed 3.00 GbpsSector Size 512BSAS Address 4433221106000000Non-RAID HDD Disk Cache Policy Not ApplicablePhysical Disk 0:0:2 Online Spun Up Available TasksBlinkUnblinkOffline ... Execute SATA HDD 02.03B05ID 0:0:2Status OKName Physical Disk 0:0:2State OnlinePower Status Spun UpBus Protocol SATAMedia HDDRevision 02.03B05T10 PI Capable NoCertified YesCapacity 232.25GBUsed RAID Disk Space 232.25GBAvailable RAID Disk Space 0.00GBHot Spare NoVendor ID DELL(tm)Product ID WDC WD2502ABYS-18B7A0Serial No. WD-WCAT1J280891Part Number TH0H962F1255216R032DA0Negotiated Speed 3.00 GbpsCapable Speed 3.00 GbpsSector Size 512BSAS Address 4433221105000000Non-RAID HDD Disk Cache Policy Not Applicable virtual diskStatus Name State Hot Spare Policy violated Tasks Layout Size T10 Protection Information Status Device Name Bus Protocol Media Read Policy Write Policy Stripe Element Size Disk Cache PolicyVirtual Disk 0 Ready Not Assigned Available TasksReconfigure ...Delete ...Check ConsistencyAssign/Unassign Dedicated Hot Spare ...BlinkUnblinkRename ...Change Policy ...Slow Initialize ...Fast Initialize ...Replace Member Disk ... Execute RAID-5 464.50GB No Windows Disk 0 SATA HDD Adaptive Read Ahead Write Back 64 KB Enabled [/INST] Hello I put the logs in a spoiler tag to make the thread easier to read. In the future, if you want to add logs to a thread then please either attach a file or provide a URL to a text sharing site instead of copying and pasting logs into a post. Log snippets are fine, but large snippets or full logs don't belong in the post body. These look like bad block errors to me. Bad blocks happen with drives, they are fairly common. If multiple bad blocks are found on a drive then it could be a sign that the drive is going to fail. Once the disk crosses a threshold for bad blocks the SMART on the disk will report the drive as predictive failure. If I had several drives that were reporting bad blocks then I would be proactive about replacing them. If it was just one drive and I had good backups then I would wait for it to go predictive failure before replacing. I didn't notice any of the drives being predictive failure in the logs. I would also run a consistency check. It is good to run consistency checks at regular intervals or when disk issues are encountered. A consistency check will verify the data is intact. You can find more information in the controller manual. [URL] Thanks </s>
<s>[INST] I have two new Brocade Switch 6520, acting as standalone, i wont merge those The default domain id is 1 I want to learn about the best practices to set the domain id for standalone switches, is there any advice to about brocade 6520 domain id must be greater o smaller than others? for example Brocade 6520-1 Set the domain to 3 and the other Brocade 6520-2 Set the domain id to 4. Does it matter domain id ranking?? Do you recommend to use or leave the default id ? or change it just for best practices Bes regards [/INST] Hi, you can leave the Domain ID at the default. It will make no difference to the switches or the protocol while running in a single switch fabric. Regards, Erik </s>
<s>[INST] Understand 3-node software update is supported from 4.5.200 and can be done by customer for vSphere Std, where can I find the procedure? [/INST] The procedure is in SolVe _[URL] </s>
<s>[INST] Hi, I have a T620 running Windows 10 Pro. The fans used to be very loud. Then they stopped being loud for a while, and now they are pretty loud again. I did not change any hardware or install any kind of updates. However, I noticed that it says when booting: 2 Virtual Drive (s) found on the host adapter. 1 Virtual Drive (s) Degraded. I would think that this (the Degraded) is the reason the fans are so loud again!? But I am not sure. I googled a little bit and found a thread on this forum where "Flash" suggested to run some sort of diagnostics. Already forgot what it is called, but it had something to do with RAID. I was going to do that, but I cannot login to OpenManage!? I have been trying all day, but it never works. I googled for a while trying to figure out what the login credentials are, and even though I believe I found them, still does not work. I found a thread where Flash is saying: "The host name is not 'administrator'. Username should be in the format: domain\username and its password. Don't check the Active Directory box if present. User MUST be a member of the server's Administrator group or a Domain Admin. User MUST have a password. Use IE, add server to Intranet Zone and try. You MUST be logged in as the admin user. Turn off IE Security Config (at least for administrators)." I googled on how to find my hostname and it is DESKTOP-L36***S (changed three characters. Not sure if I even have to?). So I use DESKTOP-L36***S/1311 as the hostname. I then do what flash said. MY Domain is WORKGROUP and my username is P. So I use WORKGROUP\P and as a password I use the same one that I use to login to my computer. Having said this. I tried every possible combination and it never works. I tried under Hostname / IP address: DESKTOP-L36***S/1311 DESKTOP-L36***S:1311 WORKGROUP/1311 WORKGROUP:1311 DESKTOP-L36***S Under username I tried: DESKTOP-L36***S/P DESKTOP-L36***S\P desktop-l36***s/P desktop-l36***s\P WORKGROUP/P WORKGROUP\P Under password I used my password. Same as the one I login with to my computer... I am sure I might have not listed all combination I tried, but trust me, I tried them all. Nothing works. Any ideas? Thanks, G [/INST] Available options will depend on the RAID controller you are using. I didn't notice it mentioned in any of your posts. If the controller supports any recovery options then they would be a re-sync, foreign configuration import, or forcing a disk online. Re-tagging the virtual disk may also be an option. You can find out more information in the controller manual. [URL] </s>
<s>[INST] Good evening All I am hoping someone can point me in the right direction, I have 3 Nutanix hosts with OVS - at the moment I am unable to configure Bond0 and I think it may be the settings on the X4012 x 2 switches at the level above. The GUI on the x4012 switches is not something I find easy to work with, so any tips gratefully received. This is what I have: [IMAGE] Can you help with the configuration of the X4012 ports - I have them set up as a Trunk - do I need anything else to make this work with a Nutanix OVS Bond Would it be ok to take cables from the hosts 1gb eth2 and eth3 to the M3024 switches to create Bond1 for DMZ VLAN. How do I check where the traffic is actually going? Many thanks [/INST] Hi All I enlisted the help of Nutanix for this as it had me stumped. The Nutanix engineer spent quite a while checking the Nutanix environment and concluded there was no problem with the HCI environment... so he took a look at the X4012 switches connected for the backbone, the problem turned out to be that the CVM had a mac address that was not being automatically added to the ARP table of the switch. Adding the mac address to the static list solved the problem, there is still a Dell support request open to try and find the root cause of the failed ARP entry. Have a splendid weekend All. E. </s>
<s>[INST] After updating Windows Server 2012 r2 on our server (DELL PowerEdge T330), after the restart, a "No boot device available" error message appeared and booting did not resume. :smileysad: Before the update, our server was working fine. What is the solution? Please somebody help me. [/INST] Hi Chris, I found the cause of the error. There are two physical hard disks in the server that are managed by the raid controller as a virtual disk.After the update when restarted the system, for some reason, booting from the virtual disk failed, and this error message was displayed: "No boot device available os Operating System detected.Current boot mode is set to BIOS.Please ensure a compatible bootable media is available." I tried to manually update the BootMGR File, first in BIOS boot mode. Thereafter booting from a Windows installation dvd, at the command prompt "bcdboot C:\Windows /s D:\" did not solve the problem. I came to the conclusion that no BIOS mode was set before. Then I switched to UEFI boot mode.The command "bcdboot C:\Windows /s D:\" solved the problem. The good solution I found here. </s>
<s>[INST] We are trying to configure DRACs on all of our Windows servers (mostly2012 R2). All R710s and R910s we have tried just worked with littleeffort. But, we haven't been able to get any PowerEdge 2950s to work.In all cases we're using a shared NIC; the DRAC has a different IPaddress in the same subnet.I can ping the DRAC IP address on three 2950s; on two I cannot.A web browser cannot get a response from the 2950s.If I run "racadm getsysinfo" on a pingable 2950, I getERROR: RACADM is unable to process the requested subcommand because there is nolocal RAC configuration to communicate with. (Same command on an R710spits out a lot of info.) There definitely is a DRAC; I can configureit by hitting ctrl-E during boot or with OMSA.I suspect a DRAC firmware update may help. I got a bootable ISO ofdrivers for 2950s from[URL] ran for ~half an hour on one 2950 and updated some things, but Ithink not the DRAC firmware.Systems-Management_Firmware_D8GP9_WN32_1.65_A00.EXE from[URL] "not compatible with your system configuration".I have firmimg.d5 from f_drac5v165_A00.exe but I don't know how toinstall it without either a working DRAC or working racadm.I can ssh into the servers where the DRAC is working, but not into theones where it is not working.I know TLS may be a problem for web access. We've disabled TLS 1.0and 1.1 by group policy, but a web browser from a machine not in thedomain also couldn't connect.In DRAC BIOS setup, the top box says 1.28 which I assume is thefirmware version. BMC was 2.1 before update, now 2.5.Any suggestions on how to update the DRAC firmware or any otheractions we should take? Thanks. [/INST] Hello It sounds like the DRAC is either not installed or not functional. The CTL E BMC/DRAC menu is available whether a DRAC is installed or not. If a DRAC is installed the BMC/DRAC menu should list a Remote Access Controller revision. You will also have a couple of extra options, like virtual media configuration. If those are not present then the DRAC is either not functional or not installed. You can find more information in the manuals. [URL] [URL] The DRAC manuals should be under DRAC and BMC manuals should be under Remote Enterprise Systems Management on the Embedded Server Management manuals link. The system manuals are on the system support page. Thanks </s>
<s>[INST] Hi i am migrating from VMAX250F to VMAX 450FX by using SRDF but i have a question, it is just to make sure that everything will work properly 1.-I created my SRDF pairs symrdf -sid 1234 -f filepairs.txt -rdfg 10 -type rdf1 -invalidate r2 2.- I established the pairs symrdf -sid 1234 - filepairs.txt -rdfg 10 -type rdf1 -est The question here I forgot to add the -full option is it going to perform a full establish or is it going to perfom a incremental??? Best Regards [/INST] When you set it up for the first time, it will replicate all the data to the R2 volume, even though a -full was not used. However, if you are migrating from a VMAX 250F to a 450 FX you should try the Non Disruptive Migration ans its way easier and highly non disruptive. .[URL]¡¦ </s>
<s>[INST] I have a PowerEdge 2950 with an attached Powervault MD1000. The connection is made through a PERC 6/E. In the MD1000 I have installed seven (7) 2TB harddrives, with the last 1 installed recently. I have been adding harddrives to the enclosure periodically and performing the "Reconfiguration" each time to add them to the Virtual Disk in RAID-5. I am using VMware 6.0 on the PowerEdge 2950 and accessing it through the vSphere Client (I do not have the vCenter Server). When I view the MD1000 through the Dell OMSA it shows a total capacity of the Virtual Disk at greater than 9TB but when I review the Virtual Disk through vSphere Client it shows a Partition of 3.94TB accessible (and the 9.09TB Capacity). I want to be able to access the entire available capacity through VMWare. Is there something I possibly missed during the installation of the hard drives into the enclosure or is there a limitation that I am not aware? [IMAGE]View of Virtual Disk from Dell OMSA [IMAGE]vSphere Client Datastore View of Virtual Disk [IMAGE]vSphere Client Device View of Virtual Disk [/INST] Hello Speedaemon, Sorry, I thought that you were changing the drives out for larger ones. Since you are just adding drives into empty slots you should be able to expand the virtual disk in the PERC utility or OMSA. Once the new space has been fully added to the virtual disk then you should just have to do a rescan in VMWare and it should see the space & allow it accessible. Since your PERC card is displaying the full size of your virtual disk I would say that there seems to be an issue with VMware. Please let us know if you have any other questions. </s>
<s>[INST] Hi, The user wants to execute Re-IP using the RP 4 VM's automatic copy VM network configuration function. However, if you look at the manual, the support OS is RHL 6.5 or 7.2. The OS version used by the user is RHL 6.6, 7.1. Is this version supported? . RP4VM version is 5.1.1.3. Regards, Hideki [/INST] These are supported, depends on the vmtools versions being used, some older versions require that DeployPkg would be installed separately. Regards, Idan </s>
<s>[INST] Hello, Is there a link for the latest firmware for the Equallogic PS4100X available? We got a new controller and now the firmware versions are mismatched. Active Controller is version V6.06 (R351932) Secondary Controller is version V8.1.1 (R417753). We can either move the active to the same level as secondary or move them both to a higher version. I'm fine with either. We are using this in a VMWare vCenter Server 6.0.0 build 7924804. James [/INST] Hello, You need to have a support contract in place in order to download the firmware from eqlsupport.dell.com. What should have been done is removed the firmware SD card from the old one and install it in the new one to keep the revision the same. If you still have the failed CM this is the best option. SSH into the array. as grpadmin and try to run 'update' That firmware is VERY old so it may not work but it should attempt to downgrade the passive CM to 6.0.6 and then restart the CM. Note: If you are not running 6.0.6-H2 (or greater) there is a risk of damage to the VMFS filesystem. Also make sure you have configured ESXi to Dell's best practices. [URL] Regards, Don </s>
<s>[INST] Hey there, VNX5200. I wanted to check out clones, so I created a test to see how it worked. I ran the clone wizard and everything seemed to go well. Unfortunately, I started getting hot spare policy errors. Seems like the process of creating the clone allocated some of my unbound drives to a RAID group for the clone. I deleted the clones, but I can't delete the associated RAID group or the private LUNs. I want to get my hot spares back. Thanks, Drew Morone [/INST] Okay, just in case someone has the same issue. Like I said, the clone wizard allocates drives and creates a raid group when you run it. Apparently on the VNX series, you don't allocate hot spares, you just leave enough unbound drives around to cover your array. My policy is 1:30 drives. Anyway, I was able to figure this out. I had deleted all of the clone references, but had missed one that was hard to find. I did the following in the GUI after choosing my device: You should see the entries there, and you can delete them. This isn't the most obvious place, so it's easy to miss. </s>
<s>[INST] Using the iDRAC9 web interface, if I go to iDRAC Settings, Services, and disable Redfish, then the next time I log in, if I go to iDRAC Settings, Services, Settings, Time Zone and NTP Settings, all of the fields will be blank, and I am unable to enter any new values, the fields are obscured. If I set Redfish back to enabled, then re-log in, the fields are once again available, and show the values that were previously set. The firmware version is 3.21.23.22. Is this by design, or is it a bug? Thanks [/INST] Redfish should require authentication to access most information. You can go to these URLs to get an idea of what would be exposed. Replace the IP with your iDRAC's IP. [URL] [URL] Those URLs will show the basic layout, If you try to access something much deeper than that it should require authentication. We should have Redfish documentation on the iDRAC support page. [URL] Thanks </s>
<s>[INST] Hi there, we've got a fresh installed NetWorker 9.2.1.5 environment running on CentOS 7.5 Linux. We have five database servers running Oracle 10g on it. The database files are stored in the following folders: Server 1 => /oracle1 Server 2 => /oracle2 ... Server 5 => /oracle5 For the database backup we're using the NMDA Module so we have this and the NetWorker client software (9.2.1.5) installed on this systems (CentOS 5.11). I want to do a file system backup for this systems as well and don't want to save the oracle folders because they are very big. I decided to create a directive that looks as follows (due to NetWorker Admin Guide): << */oracle[1-5] >> +skip: * In the client setup I chose this directive for each client and set the save set to All. When I start the Workflow for this group the backup action monitor shows the following save sets: Server 1: / /boot /oracle1 Server 2: / /boot /oracle2 and so on... It seems, that the directive is not working. I can't find anything in the logs that says the client tries to use the directive. I also created a directive for each client because I wasn't sure about the new wildcard syntax for the folders: << /oracle1 >> +skip: * Can someone please help me with this? Regards Hendrik [/INST] After the backup completes, and you browse the client's files that were backed up, you will see the oracle directory backed up, but not the files within the oracle directories. In addition, you will see the hidden files too, because your skip "+skip: *" does not skip the hidden files (those that only have extension and no file name). To skip all files in a directory, use: +skip: * .?* </s>
<s>[INST] any ideas?[IMAGE] [/INST] Please make sure that you are using a right vSphere SSO account, like administrator[NAME].local because error messages says that account that has been used does not have enough privilege to proceed upgrade. If you are sure about SSO account, please reboot PSC and VCSA and try again. </s>
<s>[INST] Hello, I need help for merging 2 switches where VF needs to be disabled. Below is our current Brocade switches configuration; Model: Brocade 6520 Switches: Switch_1 Switch_2 Zoning: Soft VF > Enabled 1) FID: 128 > cfgzone: Not Defined > Fabric: n/a 2) FID: 2 > cfgczone: Zoning_A (Defined and Active) > Fabric: Switch_1 3) FID: 6 > cfgzone: Zoning_B (Defined and Active) > Fabric: Switch_1 & Switch_2 All FIDs, i.e. 128, 2, 6 have ports connected and zoned. Scenerio 1: Disable Virtual Fabric (A) We need to get rid of virtual fabric, i.e. FID 2, 6, and finally 128 (B) I need Default switch into Fabric with no impact to current zones and alias. > I am ok with Downtime of assets connected > I am ok with creating a New Defined Zoning Configuration. Scenerio 2: Keep Virtual Fabric Enabled, but delete FID 2 & FID 6, so using just Default FID 128 > I am ok with Downtime of assets connected > I am ok with creating a New Defined Zoning Configuration. > What will happen to zones and alias when ports are move from FID 2 & FID 6 to FID 128 > What will happen to zones and alias when finally all ports are in FID 128 and we disable Virtual fabric Step by step process to achieve scenerio 1& 2 will be highly appreicated. Thanks [/INST] Hi, Scenario 1: - Remove zoning. - Move ports from LS to default. - Delete LS. - Once done, in default switch disable VF, and reboot. - Re-create zoning. Scenario2: Is easier. - Remove zoning. - Move ports to default switch. - Delete LS. - In default switch re-create zoning. </s>
<s>[INST] I have a Dell Powerconnect 2824 with a Pfsense router connected to it. Newbie to Vlans. I'm trying to create a vlan so that I can put my IOt devices on the VLAN separate from the rest of my network. I have been trying to get just 1 extra computer on the Vlan 50 that I made and I can't seem to make that happen. I have Pfsense setup with the Vlan lan tag 50 and a subnet of 192.168.50.0 mask 255.255.255.0. I have been reading countless posts on here and Netgate to get this setup right but count seem to figure it out. To test I have a computer on port 2 of the switch set to PVID 50 of the Vlan I made. My Pfsense router is on port 23 so I have that port tagged. The rest of the ports are still in the default vlan 1. I don't get a IP address on the test computer, just a 169 IP address which I think it means it is not working. End goal is to use my new unifi AP that tags traffic to put all the IOT traffic on a separate vlan along with home assistant rasberry PI on that same Vlan that controls many of the IOT. [/INST] The tagging and untagged settings on the switch and AP need to match. If the PVID is 1 and the tagged VLAN is 50 on the switch, then the AP needs to be untagged for VLAN 1 and tagged for VLAN 50. </s>
<s>[INST] I am trying to download OME Enterprise and nothing happens when I fill out the form. I've tried multiple times throughout the last week or so and also with Chrome and I.E. to no avail. Any ideas? [/INST] Hello Now that it is a full release product, as of 3.0, it should be on the system support page. I just checked the support page of an R430, and it is listed under the Systems Management category. You should not need to fill out that form to get a download link. [URL] Thanks </s>
<s>[INST] Our enterprise is planning to buy a PowerVault MD3420. We already have a MD1420, with 2 Virtual Disks, connected to a PE R730 with a PERC H830. My questions are: Thanks [/INST] Hi, You will need a Non raid controller since the MD3420 has its own controllers. This is the part number for the SAS controller. 405-AADZ. I do not see a way to import the virtual disk from a PERC to an MD3420. </s>
<s>[INST] I have a stack of Force 10 MXL switches in an M1000e chassis. I would like to confirm how to gain access via serial cable to these switches. I assume I use a normal 9 pin D-sub to D-sub cable to connect to the serial interface on the chassis controller? From there I assume I can use the "connect switch-n" exactly as I would when connected to the chassis management controller via SSH? Once connected using the "connect switch-n" command, how does one disconnect? The documentation here doesn't mention that step: [URL] Thanks! [/INST] Yes, the serial cable connects directly to the switch. From a serial connection to the CMC, you can use the connect command to establish a session to switch. </s>
<s>[INST] [IMAGE]Hi Does any one know if i need to install a license for Time Finder SnapVx on VMAX All Flash 450FX with solutions enabler 8.4??? i found this info, but i need to make sure if i need or i dont need it (License) Best regards [/INST] yes snapvx is a licensed feature. But VMAX series are already elicensed so you don't need to load license manually anymore. DellEMC CE will apply (based on sales order) and add elicenses into box for you while he is installing/upgrade it. </s>
<s>[INST] We have VMware ESXi on Dell VRTX blade. It has 8 external port and 16 internal port (4 port * 1 blade). We have connected cables as per below, External port 1 - VLAN 10 (MGMT / vMotion) External port 2 - VLAN 20 (Backup) External port 3 - Trunk port External port 4 - Trunk Port External port 5 - VLAN 10 (MGMT / vMotion) External port 6 - VLAN 20 (Backup) External port 7 - Trunk port External port 8 - Trunk Port Can anyone please let me know how the mapping of external port is happening with internal port at the ESXi level. We can see 4 NIC adaper at each of the ESXi console. Not sure, how they are communicating/mapping with external switch. [/INST] The 2401 is a switch and not a passthrough there is not a one to one mapping, all ports can talk to all of the other ports. </s>
<s>[INST] I've noticed something new on Dell configurators that I haven't seen before. So far, Google hasn't been my friend. There appears to possibly be a new variation of SSDs with the designation of "AG Drive". Here is an example of what I'm seeing: PowerVault MD3060e Dense Enclosure | Dell United States 960GB SSD SAS Read Intensive 12Gbps 512 2.5in Hot-plug AG Drive Does anyone know what the difference is between AG drives and other drives? Maybe it's something internal to Dell or there's a technology that I'm not familiar with. I would greatly appreciate any thoughts. Some thoughts of mine are Ag is silver on the periodic table. Panasonic part number sometimes start with AG. AG drives seem to cost less than other SSDs. [/INST] Hi, Please do not post the same question in multiple locations. AG stands for agnostic, it is drives with certain specs but that may come from multiple manufactures rather than a specific branded drive. </s>
<s>[INST] Hello guys, I just wonder why command "terminal monitor" when entered in SSH/telnet session is not working. Switch model is N1548 or N1524P. I cannot see any output in SSH session (eg link state changes, STP, dot1x port changes etc). These kind of status messages used to work in previous models (eg 3548) even without "terminal monitor" command needed. Am I something important missing? Any further configuration commands? Or should this status messages even normally appear as I expect? :) I am confused. [/INST] Those are the only two commands I am aware of that would impact the telnet/ssh output/logging. </s>
<s>[INST] Quick question. I have a Dell Perc 6i RAID controller and need to move the port cable from A to B (cable length issues). Can I just move the connector over and keep the RAID? Or will I have to rebuild it as it is on a different port? Basically I connected it to port 1 (left side) and simply want to move it to port 0 (right side). Will it keep the Virtual Drive intact if I just move it? Thanks! [/INST] Gavin2812, You would likely need to move the drives to the other side of the backplane, in order to be visible to the controller. You shouldn't need to do anything beyond that I don't believe, but you may have a foreign configuration. If that is the case then import the foreign to proceed. Let me know how it goes. </s>
<s>[INST] Hi folks, we have a customer having trouble accessing their Isilon OneFS API through our software. We keep getting bad user name or password as an error. They are even trying the root user with no luck. That same user can login to the web admin interface using the same credentials. The first thing we do is create a session according the API doc. If we deploy a simulator out of the box, using the root user and what ever password at cluster creation time, our product has no problem. But our customers are frequently having problems with this. Are there some settings that restrict access to the API? What should I be looking for? Edit: I just realized something, when we send the POST request to "/session/1/session" we actually send BOTH platform AND namespace as services. Could it be that we don't have namespace privilege and thus can't get a session cookie? I will test this theory. [/INST] amarcionek What OneFS & patches? This might be your issue. API Auth Changes with Recent Security Patches (anti-CSRF token) </s>
<s>[INST] Hi, I was planing to upgrade dell essential 2.4.0 and was reading its user guide and i did not found any information regarding 9th generation servers specifically DELL PowerEdge 2950. Kindly can any one help me out in this issue as how i will manage these servers through Dell OME. [/INST] To prevent having to dig into the manuals, I figured I'd just say it: - only 10th generation and newer servers are supported by OME. This isn't too unreasonable as 9th generation servers were released in 2005 and 2006, which is well over 10 years ago. </s>
<s>[INST] Hello I need to upgrade the memory on the R320 and I've wondering if I can use the old ram to put it on the C6220 Because those 2 servers are the same generation I hope I can use it !!!! Thank you [/INST] Hello Maybe, if you get the model or part number from the memory you can search to see if it is for sale online. If it is for sale online then it would likely have a listing of compatible systems. You can also review the memory population rules on the C6220 to see if there would be any issues moving the memory. [URL] Thanks </s>
<s>[INST] Dear all, I have this warning in my RP configuration: RecoverPoint copy contains volumes from more than one VPLEX consistency group. It is recommended a RecoverPoint copy contain volumes from only one VPLEX consitency group. VPLEX consistency group: [No VPLEX CG,produzione] ; VX-DCSIT-RPA I checked all the CG,and I did not find volumes replicated in more than one CG. Can someone help me understand this warning? Regards, Jacopo [/INST] Try switching the Site Control by using the cluster IP address, logging in as boxmgmt and rebooting that RPA. I¡¯m pretty sure there is a KB for this. Have you checked? </s>
<s>[INST] Hi all, I am trying to install Windows Server Essentials 2016 on a T320. I am using a USB key as the boot media. Everything loads fine, until the computer restarts after the initial phase and then I get the windows logo screen. At first it is a high resolution screen then downgrades to a low resolution image with the circle of dots surrounding the windows logo and then nothing happens. If I do a cold restart at that point the installation fails and I have to start from scratch. I am thinking it's a driver issue? I cannot deploy Server 2016 through the LLC as it is not one of the available options, however Dell has certified Server 2016 as an option for T320. At installation, Server 2016 recognized the hard drive and all, no issues there. I have a Raid 10 array of SSDs with one VD already configured for OS deployment. I guess my only other option would be to install Server 2012 R2 and do an in-place upgrade to 2016? Any ideas from anyone would be welcome. [/INST] Ok, So after trying multiple things, here what worked: download the video Matrix driver from Dell (this is the one for my server, check your particular model): [URL] ***during server 2016 install, press the button "load drivers" at the screen where you are picking what drive to install the operating system on and select the appropriate folder where you have video driver saved (I would recommend a USB drive). Pick the matrox video driver. After that everything went buttery smooth. The frustrating thing is that this is a very simple issue to have a workaround, yet there is no mention anywhere in the Dell tech support documents, even though quite a number of 12th generation servers that have been certified as compatible with Server 2016 (I do remember somewhere in some obscure document a mention that the video card is an issue with server 2016, but there was no advice given). Better yet, Dell should just make Server 2016 an option in the lifecycle controller OS deployment ->it would make life easier for everyone since most other drivers are inbox with the server 2016 installation media. As well, check the device manager after install (right click on "this pc" on the desktop and select properties, then look in the upper left corner -> I had to manually install a number of drivers from windows update ->just right click on any devices that server 2016 did not recognize and pick update driver. Cheers. </s>
<s>[INST] I have the following setup: Both VMAX arrays are 250F models. R1 (5TB) ------//-------> R2 (5TB)----(no copy linked snapshot)--->snapvx tgt devices (1TB of changed tracks) (split) If I perform a deletepair and full establish on this RDF devices, what happens to downstream linked snapshot ? Will it consume all 5TB since the full establish causes all tracks to change on the R2 side ? You might ask, why are you doing full establish ?? I just need to know what would happen.[IMAGE][IMAGE] [/INST] A Full Establish will send all of the data from the R1 to the R2 (well the tracks with no data won't actually be sent as 128KB of zeros, but marked as sent). Any data that is changed on the R2 as a result of the Full Establish AND has not already been modified since the SNAPVX snapshot was taken will add to the PIT data being kept. So assuming there is actual data on all 5TB, then your 1TB of snapshot will grow to 5TB. SNAPVX is just doing its job of preserving the PIT on the R2 device. It doesn't matter where the changes to the R2 come from. </s>
<s>[INST] Hello, trying to File level restore to a VM. We got two IP for each ESXi. One is dedicated to Management (1Gbps), and the other network/vmkernel is dedicated for backup (10gbps). When we are doing backup and restore as we use the hosts file on proxies we can successfully backup and restore by the backup network. But when we are trying FLR restore, vProxy quesry the vCenter for location of the VM, and vCenter answer back with only one management IP and as you guess... the 1gbps network which is NOT accessible from vProxies. To be clear : ESXi (vmkernel)/ vCenter (dual IP)/ vProxy / NWS / Datadomain / other backup stuff are all in the same VLAN which is called backup. they have ONLY ONE Network card / IP (backup). and ESXi & vCenter have another IP on "Management Network". they have TWO network card / IP (management / backup). We try to tag the secondary vmkernel as 'Management Network" on ESXi with no luck. vCenter queries always return only 1 IP. We also try to modify the hosts file on vProxy. with no luck as the vcenter answer an IP and NOT a hostname (which is quite stupid as networker rely on DNS). Any documentation or help on dual IP on ESXi or dedicated network interface (vmkernel) for backup? Really apreciate help on this topic. Regards, Jacques [/INST] We done that the "hard" way... Route add mannagement_front_ip via management_backup_ip. You said what? Yeah Yeah! Iin Production of course! Bullshit that EMC should change! Never saw that in VEEAM / NAKIVO / NetBackup / Rubrik and so on! EMC is the only one where we can't select backup lan. Lastest experience with Networker Bullshit at all! I'll move to another backup solution next year and be sure i WON'T select EMC one. </s>
<s>[INST] Hi, I want to change the alert severity in smarts for the tickets generation, I understand that we need to change the config fils for that but I'm not sure if I'm trying t0 degrade the alert also that means from 1 to 3 for few devices ,will just changing the changes in file do that or there is any other way to do that? [/INST] Hi Yes it's fixed now.. Thanks a lot for your help </s>
<s>[INST] Hello, I have an issue with a Dell R640 on UEFI. I set PXE boot on 1st place in boot order, and once installed a ubuntu linux (or other), the boot order change and the boot on disk go first (with ubuntu). I see other issue about that topic, but no solution.. - Here the same questions on the french forum, but answered is provided in private - Here someone fixed it with cctk, but it's not available on linux.. What are my options ?? [/INST] We do not have a feature like fixed boot order. </s>
<s>[INST] I am looking for documentation about power supply redundancy in the H500 nodes in our chassis. Our chassis has 4 H500 nodes each with a single power supply. We have 2 PDUs in the rack, each on it's own circuit. Nodes 1 and 3 are on PDU A and nodes 2 and 4 are on PDU B. What happens if PDU B loses power? I assume that power from node 1 would keep node 2 up and node 3 would keep node 4 up. Is that really what happens? Our maintenance department is reworking some power in the data center and they will need to take one PDU down to change circuits. I need to make sure that we do not have an outage while they work on the power. [/INST] Gen6 nodes are grouped in pairs and share their power supplies. In each group, one power supply can fail without a node failing. But if the last connected power supply fails, two nodes will fail. See this post for further details: Next Gen Nodes [IMAGE] </s>
<s>[INST] HiI have a Equallogic PS6000 running FW V5.2.6 with 4400 Lost Blocks after a power outage. Other places in this support forum I see a script that can be run on the device. Since the devices are are of support where can I obtain the script?Kind regards Christian [/INST] Hello, Yes, mark valid is your best bet at this point. You can create a snapshot first if you wish. Then you can revert quickly w/o needing 2x the space. You need to rescan or even reboot the hosts afterwards. Regards, Don </s>
<s>[INST] Hi guys! I'm trying to find out if I have the right switch for the job. I want to connect servers using LACP bonding so I can get redundancy and double bandwidth. If one switch fails everything should work as before except with less bandwidth. Will this work with two stacked N1124T-ON switches?[IMAGE] [/INST] That setup looks good to me. The user guide has some good information on how to configure Link Aggregation and Stacking, if you need it. Stacking page 231 and Link Aggregation page 1029: [URL] </s>
<s>[INST] Hi All I hope all is well in your world. If you are not too busy can you just have a look at these snippets of switch config. I did them years ago and looking at it now, how is it working? TOR seems to have interface port-channel 1 and 2 ? is port-channel 2 surplus to requirements - are the Switchport settings ok or are some of them redundant too? TOR switch: interface Te1/0/1speed 10000channel-group 1 mode activedescription "Link to M8024K L Port 20"switchport mode trunkswitchport general pvid 32switchport access vlan 32switchport trunk native vlan 10switchport trunk allowed vlan 2-4093exit!interface Te1/0/2speed 10000channel-group 1 mode activedescription "Link to M8024K R Port 20"switchport mode trunkswitchport general pvid 32switchport access vlan 32switchport trunk native vlan 10switchport trunk allowed vlan 2-4093exit interface Te2/0/1speed 10000channel-group 1 mode activedescription "Link to M8024K L Port 19"switchport mode trunkswitchport general pvid 10switchport access vlan 10switchport trunk native vlan 10exit!interface Te2/0/2speed 10000channel-group 1 mode activedescription "Link to M8024K R Port 19"switchport mode trunkswitchport general pvid 10switchport access vlan 10switchport trunk native vlan 10exit!interface port-channel 1description "To M8024K"spanning-tree portfastswitchport mode trunkswitchport access vlan 32exit!interface port-channel 2description "To M8024k"spanning-tree portfastswitchport mode trunk Blade switches 8024 stacked: interface Te1/0/19channel-group 1 mode activeexit!interface Te1/0/20channel-group 1 mode activeexit interface Te2/0/19channel-group 1 mode activeexit!interface Te2/0/20channel-group 1 mode activeexit!interface port-channel 1switchport mode trunkexit Any assistance much appreciated. [/INST] It does not look like there is any interfaces in port channel 2, but I would double check the running config before getting rid of it. Once an interface is placed in a channel group, that interface then only follows the commands issued to the port channel and not the individual interfaces. Portfast is intended for use with end devices such as workstations. When enabled portfast immediately places the port into a forwarding state and should not be used on switch to switch connections. Example of cleaned up configuration: interface Te1/0/1 channel-group 1 mode active description "Link to M8024K L Port 20" exit ! interface Te1/0/2 channel-group 1 mode active description "Link to M8024K R Port 20" exit interface Te2/0/1 channel-group 1 mode active description "Link to M8024K L Port 19" exit ! interface Te2/0/2 channel-group 1 mode active description "Link to M8024K R Port 19" exit ! interface port-channel 1 description "To M8024K" switchport mode trunk exit Hope this helps. </s>
<s>[INST] Dear all Hi how can i get latest version of power path for windows ? BR Babak [/INST] i have posted the link below [URL] i hope this helps thank you </s>
<s>[INST] Our Powerdge PowerEdge T130 Server Invoice states - S130, Software RAID (for Microsoft OS Only)- RAID 1 for S130 Does this means this is software-only RAID? Is this reliable? I have read about software RAID being deprecated... [/INST] Hi Riccardo, The PERC S130 is software RAID, intended as an economical solution where performance isn't a concern. A dedicated controller card (H730 for example, supported on the T130) would give you better performance. Most controllers without cache have limited write speeds. This article explains in more detail: [URL] Thanks, </s>
<s>[INST] Good day to All I have a bit of confusion going on, possibly just in my head! I have 2 x M3024 power connects stacked, then I have 2 x X4012 switches which attach to Nutanix. My problem is that I keep getting a loop when I connect the stack to the second X4012. See photo for layout. [IMAGE] Am I correct in using the same Port Group number from both x4012 switches or should it be different? and Do I add the vlans the Port groups or the ports themselves? I have used RSTP on all the connections yet still I get locked out when I connect the X4012 sw2 to the 3024 stack. The X4012 is quite difficult to work on as most of the config seems to be done in the GUI. Any ideas or script examples would be appreciated. [/INST] A port channel needs to connect from one device to one device. Stacked switches are logically one device. This means that currently you have one port channel split between two devices. To alleviate this you can get rid of port channel 10, or change one of the connections to be a different port channel. The X-series switches do not support stacking, so with a setup like this you will end up with a physical loop and spanning tree will kick in on one of the connections. When configuring a port channel you will need to add the VLANs to the port channel not the individual ports. </s>
<s>[INST] The situation is as follows: I have a PowerEdge T620 that has had a failed drive in an unknown RAID configuration for a year now (!). According to the T620 manual, I need to disable the faulty drive through iDRAC before I can replace it and rebuild the array. Unfortunately, I don't have the login credentials for the iDRAC - the server was set up by a technology consultancy which claims to have already deleted/passed on all relevant password data (They did, but overlooked the iDRAC credentials when doing so...). The server is running ESXi 5 with several mission critical Windows Server 2012 R2 VMs. My goal is to reset the iDRAC password (perhaps using OMSA?) WITHOUT triggering a reboot, so that I can replace the failed drive, add a hot spare or two, and rest easy. Is this possible? I've tried using racadm, but uinstalled it after getting an "Unable to communicate with the BMC" error. I'm wary of installing OMSA because I don't want it to trigger a reboot, but if that fear is unwarranted I'd be willing to try it. I have access to vCenter, ESXi (over SSH), and all of the Windows VMs. Just not the iDRAC. I'm also almost 100% sure that the username is root or administrator, but don't know the password (not that that helps much). I'll answer any questions as best I can. Any and all help is greatly appreciated! [/INST] You have to install it on the host OS, it won¡¯t pass through the commands to a VM. That is also why racadm didn¡¯t work installed on a VM. As for pulling the drive, it is fine most of the time, but it would be better to do it with offlining the drive first, but if you can¡¯t have downtime that is better than leaving the array degraded. Having downtime to reconfigure the drac is the best option though. </s>
<s>[INST] Hi, I have 2 MD3800i each with one MD1220 attached. MD3800i has a RAID6 group, and MD1220 has another RAID6 group. I already have 3 LUNS replicated well. I recently created a LUN on a part of the free space left. When trying to create a replication pair from the MD3800i I would call VHD1, it tells that there's no referential, free space configured on the VHD2. I tried to add the lun to an existing replication group, same problem. I tried from VHD2 to VHD1, same thing. Did some defrag, no more results... does someone has any suggestion ? Regards. [/INST] Hello informatique22, It sounds like there is not enough free space to store your replication. You can create the VD which you have done but you also need space for the replication repositories. If there is no space for the repositories¡¯ then it will fail to replicate. Please let us know if you have any other questions. </s>
<s>[INST] Good morning all, I have a DD2200 and Networker 9.2.1. I have 2 LANs : - management (ethMa) - backup dedicated (veth0) [IMAGE] I'd like the backups to use the dedicated backup network only (on veth0) (I'm backuping servers, each of them have a dedicated NIC in the backup LAN) In Networker, the clients are configured to backup to the DD, I have a list of DD interfaces but don't know what it stands for : [IMAGE] Could someone help on this ? [/INST] Dear Cberger, You setup that in DD. Not in Networker. It is under Protocols - DD Boost. There is a tab with Interface group settings. From here, you add the veth0 ip in there and remove the ethma ip. </s>
<s>[INST] We purchased an R740xd a few months back and were told that it would be no problem attaching to a MD1220. The 1220 is loaded with 24x1.6TB MU SSD drives at large cost so there is no easy way to just replace it. However, it now appears that is not (easily) possible. So I had a few ideas and was hoping someone else had at least attempted them: 1 - Buy a 1420 with minimal drives, put in the 1.6TB SSD drives from the previous (MD1220) array. I belive they would need new drive caddies, but I am hoping at least the drives themselves would work 2 - Instead of a Dell PERC adapter, use a 3rd party adapter like Adaptec or LSI. My concern here is that the R740xd doesn't even see the older PERC adapters like the 810 so I am not sure if it would see these either. Any suggestions would be helpful [/INST] Typically I'd expect the R740XD to 'see' the H810 just fine, except maybe in OMSA and/or the iDRAC (other than recognizing it in a PCIe slot). However, if your R740XD only came with a single processor, not all PCIe slots are functional. This could easily be a reason why the card isn't recognized. This page has an overview of which PCIe slots in which riser attach to which processor. If you do have just 1 processor, to upgrade to dual processor (so you can use all PCIe slots), will require an exactly matching processor. If you already have dual (identical) processors, this obviously wouldn't be a possible cause to your issue. Another option is to add a PERC H830 to your server, get a 12Gbit to 6Gbit SAS cable and connect the MD1220 to the PERC H830. </s>
<s>[INST] We have both Equallogic and Compellent storage in our env. and we use both SAN HQ and Storage Manager to manage the storage array. Can someone confirm Storage Manager can be used as replacement of SAN HQ? We I know I can add PS group in the storage manager but not sure if it will collect the same information as SAN HQ. Thanks [/INST] Hello, Storage Manager is not a replacement for SANHQ for PS Arrays. Storage Manager allows a limited set of management features and allows replication to / from the PS groups. It does not provide performance or IO monitoring like SANHQ does. Additionally SANHQ has SupportAssist for PS arrays and will send data to Dell for monitoring and support case creation on HW failures. Lastly SANHQ provides a lot of data for support folks when triaging PS group problems. Regards, Don </s>
<s>[INST] Hi, We have Unity 400 with 2 additional DAE. We are planing to add another DAE. Then we want to know after we adding the DAE to existing system and correctly cabled the all the back end mini SAS cables, is Unity system recognized the DAE automatically ? And also what is the process of adding additional few disk to existing DAE ? Pls advised. Thanks, Pasindu. [/INST] solveonline.emc.com is great if you don't want to have a local desktop app that often needs updating. </s>
<s>[INST] Basically all I need to do is use like a dell resource or official tool/software that can help me calculate the BTU of my servers so we can add a proper cooling solution. If anybody can help I would really appreciate it. [/INST] Hello EIPT is our current calculator tool. Our older calculators may still work. DCCP is the oldest one I can think of, ESSA was after that, and now we have EIPT. [URL] Thanks </s>
<s>[INST] Hi , Can anybody help me in knowing why we need to change the soothing level if we are changing the event severity in emc smarts? I found this document online which says that the soothing interval should be decreased by 1 sec when we are changing the alert severity, But I'm not sure why it should be done also what difference it will bring ? Can anybody please help me on this? For example : Change the following: sev Processor_Performance HighUtilization Resource 2 To the following: sev Processor_Performance HighUtilization Resource 3 This is the part of the document that I found online , any help will be greatly appreciated : Before making changes to the above file, please take backup of both the files 5. Make a change to Smoothing Interval, example from 65 second to 64 second for the domain type you are changing. Run reconfigure for the change to take effect. Change also takes effect when SAM domain is restarted i.e please restart the Incharge-SA service. [/INST] Hi, The reason for reducing the soothing interval by a minimum of 1 second is to enable the reconfigure button. A reconfigure must take place to apply the changes to the event severity level. Ron Miller Advisor, Enterprise Tech Services Vmware Dell EMC | Services </s>
<s>[INST] Hello Everyone, I have huge problems with Dell VRTX. We have 4 nodes installed with vSphere 6.5 in VRTX Chassis. We have already configured 4 servers with one Datastore which is taking from Virtual Disk of VRTX. Then, we have shutdown 4 servers and took out them to move physically to another site. After we moving and set up and power on all servers,the shared storage is not shown in all ESXi hosts. The status on virtual disk of CMC showing healthy and no errors on CMC. But the ESXi hosts do not know any storage devices. I rescan HBAs and reboot all hosts. But it seems no storage. :( Could you guys please provide my checklist and best practices. Have a nice day. Thanks you. [/INST] Now my problem is solved by changing the access of virtual adapter. Have a nice day all. [IMAGE] </s>
<s>[INST] Best place to learn about the details of Poweredge server specs. Any book available? Thanks in advance [/INST] Fedora123, To answer technical questions and things it would be best to look in the servers manual, which can be found at support.dell.com, then you can enter the service tag or click Browse all products - Servers - Poweredge then select the model. From there you can select Manuals on the left, or to get a servers configuration when shipped (or currently) you can go to System Configuration tab on the left of the page as well. Hope this helps steer you in the right direction. </s>
<s>[INST] I recently inherited an old network with a failing 3com switch. I am trying to replace the 3com switch in the simplest manner possible with a N2048. Currently, our ISP connection comes in on port 24 (via ethernet handoff from a Level3 router in our basement) on the 3com switch and our firewall plugs in port 48 of the 3com switch. I have attempted to configure the N2048 exactly the same as the existing 3com switch. When I do this and patch the connection in, I have connectivity in our local subnet as well as internet. However, I cannot communicate to a subnet that connects to a remote office. Local subnet: 192.168.6.0/24Local internet gateway: 192.168.6.38Local gateway for remote subnet: 192.168.6.9Remote subnet: 192.168.5.0/24 The remote subnet is accessed through the same connection as the internet via vLAN and static route that the ISP set up. I have the original document that the ISP provided for the configuration as follows: Customer CPE WAN Interface Configuration Requirements: 100M Full Duplex Customer WAN Netblock(s) CIDR - Subnet Mask: Vlan 100 207.67.73.184/29 - 255.255.255.248Vlan 1 192.168.255.0/30 - 255.255.255.252 Customer CPE Default GW / Remote Neighbor IP:207.67.73.185192.168.255.1 Static Route:192.168.6.0/24 - 255.255.255.0 destination 192.168.255.2 On the N2048 ports 1-48 are members of VLAN 1 and ports 24,48 are members of VLAN 100.VLAN 1 are untagged and VLAN 100 are tagged. Comparing the 3COM and N2048 switch everything seems to configured the same. It seems this should be a simple setup but I cannot figure out why the N2048 will not communicate with the remote subnet. Any thoughts or advice would be greatly appreciated. [/INST] Thanks for posting up the config. I Suggest removing vlan association on VLAN 100. You may need to add a static route for the remote subnet. Something along the lines of: ip route 192.168.5.0 255.255.255.0 192.168.6.9 Which device has IP address 192.168.255.2? I am not sure I am fully understanding the static route on the router. </s>
<s>[INST] Have several Dell c1100 PowerEdge 1U servers that need to have the latest BIOS installed to patch Metldown Specter vulnerability. I used the service tag number to find the correct BIOS and used the Linux .bin file. It runs, identifies the server as a c1100, then says that it's not compatible with a c1100. Screenshot below: [IMAGE]c1100 bios not compatible with c1100 Anyone have ideas? Thank You! didj9k [/INST] Solution found! I was able to get the BIOS updated! Since you confirmed it was a "standard" c1100 and, I thought I would to ignore the error and push the BIOS upgrade without the "file ID" check. I downloaded the DOS image BIOS image, unzipped it and copied the files to a FreeDOS bootable USB, then edited the F.bat file to ignore the file ID by adding /X to the end of the line: #F.bat Original Afudos S99C3B25.ROM /P /B /K #Add /X to ignore File ID mismatch error Afudos S99C3B25.ROM /P /B /K /X It successfully pushed the new BIOS and successfully rebooted after with the updated BIOS. Thanks for pointing me to the DOS "floppy" patch method! -Didj </s>
<s>[INST] When I login to my tech release it tells me there is an update to the lexington console but when I click it the page just refreshes it doesn't download anything or prompt me to do anything, what gives? I also see nothing in the documentation of 3.0 for updating from the tech release, and I see no place in the tech release to check for an update to the console. [/INST] So, I rebooted the device and some menu items that were not showing are now showing and I was able to update. </s>
<s>[INST] Hello.I try to upload remotly an SSL LDAP certificat on a DELL server, by using the "racadm sslcertupload" command, but this one generate the following error: Command used (as root) to upload the certificat: Content of my certificat file: PS1: The used certificat is certified by an athority of certification (CA).PS2: I have created also an auto -certified certificate and used it, but I have the same error. ENV:OS: RedHat/CentOS 7.Hardware: DELL PowerEdge R740xd Do you know how to resolve the problem please?Cordially.Liloulinx [/INST] Hello. Finally the problem is resolved by updating the firmware (or juste by the RESET of the iDRAC). Thank you </s>
<s>[INST] Is anyone using the command line? I was wanting to schedule an export but must list them and get the version first. This is where I am having issues. The documentation states to list repositories, use drm --list= I have tried that but get Invalid value every time. drm --list=JOB does work as well as drm --list=PLUGIN but I can't get the repositories to list. I even created a repository and then tried to list it which failed? Any ideas? Thanks! D:\Program Files\Dell\Dell EMC Repository Manager>drm --repository=Repotest --createCreating repository RepotestJob Submitted for repository creation D:\Program Files\Dell\Dell EMC Repository Manager>drm --list=Repotest Invalid value [/INST] Hello I think the correct syntax is: drm -li=rep We should have documentation on the Repository Manager support page. [URL] Thanks </s>
<s>[INST] Hi, I want to upload a previously saved, unaltered configuration file into the X1052P switch (firmware: 3.0.0.99) via https. The switch always crashes and reboots when I do this. How to reproduce: Switch Management > File Update and Backup > Backup Files > Edit Transfer File Name: Running configuration, Backup Method: HTTP Save the file locally on your computer. Switch Management > File Update and Backup > Update Firmware/Configuration File Type: Configuration Download, Update Method: HTTP, Destination File Name: Running Configuration. Select the previously saved file as Source File Name. Click Ok. The transfer starts. After a few seconds the switch reboots. This is output on the serial console: The configuration itself seems to be ok: When I copy the config file onto an usb drive, plug it into the switch and use something like this on the cli: the configuration is applied successfully. So the problem seems to be in the handling of the config download via http/https. The copy operation on the cli does not always succeed. It fails if there is a specific access-list configuration used in the configuration. If the configuration contains this part: copying the configuration files on the cli fails with When I remove the access-list part from the configuration file, copying on the cli works again. The crash shown above does not depend on these lines being in the active configuration or not. So this seems to be a separate issue, but also related to parsing configuration files. Please take a look at both of these issues. Thanks. [/INST] I can confirm that this problem is fixed with firmware 3.0.1.1 </s>
<s>[INST] We have isilon cluster with multiple nodes, NL410, NL400, X400 and A400. Had a requirement to migrate data from NL410 to NL400 node pool. I understand with smartpool license we can update default filepool policy, update targets to new nodes, lets say A400 in this case. Will this policy take effect for new writes only. How can I migrate existing data from NL410 ? [/INST] Short answer: 1) Adapt the default file pool policy so that all data is stored on the new tier. 2) Start the SmartPools job manually to make this change for all data. But there are more points to keep in mind. Have a look at some other community threads: Node migration leveraging smartpools Isilon smartpools migration with multiple node types (other) Phil </s>
<s>[INST] My apologies in advance if this question is stupid, but I'm trying to figure out the correct firmware for my R520 Poweredge server. I know it has a PERC H710 but where I'm getting confused is whether its a mini (monolithic?) or not...when I look up the configuration on Dell's support page using the service tag, it shows I have a H710 (not mini) [IMAGE] but when I look at the PERC details in OMSA, it shows PERC H710 Mini [IMAGE] The drivers and downloads shows firmware for both, but I'm not sure whether to use the H710 mini (monolithic?...not sure what that even means) or the regular H710 [IMAGE] [/INST] Hello You have the mini version. The two pictures I deleted had your service tag in the URL. If you want to repost them make sure no personal information is included. Thanks </s>
<s>[INST] Dear all, I own currently a second-hand Poweredge R420, with a non-redundant 550W power supply, 2 processors and 64 GB of memory. This power supply seems to be unable to accept more memory. I plan to change the non-redundant for two 550W redundant power supply units. I think that I need something mre than theses two units. I searched on google, looked many Youtube videos without success. Could you please give me some hints of address of documentation ? Thanks a lot Best regards H. Delebecque [/INST] Sorry I misunderstood your question. Yes, the power distribution board (PDB) needs to be installed and 0G8CN is the correct part number. Instructions for installing/removing the PDB start on page 100 here: [URL] </s>
<s>[INST] How to configure GVRP on S4128F switches to send the VLANS details to access layer 1500 series switches ? I couldn't find any configuration guide for configure GVRP in S4128F switches [/INST] My understanding is that GVRP has not been included in OS10, and is slated for a future release. I had some looking around in the user guide, just to be sure, and could not find any commands related to GVRP. </s>
<s>[INST] Hi, I have an X1052P switch (firmware 3.0.0.99) and want to limit access to the management interface to the protocols https and ssh, access to both should just be allowed from vlan1. When I edit "access profiles and rules" in the Web UI, I can just allow or deny one protocol per access profile, not multiple ones. But there is a "priority" field which suggests that multiple access profiles can be active at once. But the screen to activate a profile just allows activating one, not several. Then I tried it using the backup files. There are several entries with "management access-list" and just one entry "management access-class", the latter seems to denote the one active access list. So from this perspective it looks like really just one list can be active at once. So I tried to include several entries in the access list like this: When restoring this file, the switch crashed and rebootet: So how do I limit access to two management methods/protocols and a specific vlan? Thanks. [/INST] Looked around at the access profiles some more and found that once you create a profile you can add multiple rules to that profile. Once you have all of the rules you want, then activate that profile. Here is a screenshot to help. [IMAGE] </s>
<s>[INST] Hi All, this is a RecoveryPoint system managed by 2 x RPA clusters and performed through the RPA Clusters interface. One of RPA is failed and we have to replace it, so What is the procedure to do that? Would it be a matter of rewiring both network cable and fibers, configuring the cluster again, and we would have to create new zones on the switch? Thanks in advanced, Regards. Cristian [/INST] Sure. here you go. [URL] </s>
<s>[INST] Hi, We have the NW 9.1 deployed on a VM. OS is Win 2012 R2. We are expecting backup slowness on our DB client. It contains ~1.4 TB data. We are use the client direct for backup the data to DD. To investigate this issue we have rendered the daemon.raw file in the NW server and go through it. Then we are able to identified client direct backup it not happening. Pls refer the below log output. 70896 9/19/2018 4:00:50 AM 0 0 2 8440 1320 0 win-afvg9er8ckm nsrd NSR info prdbsvr1:DB2:/PB_PROD/NODE0000 saving to pool 'Digital_Banking_Prod_DB' (DigitalBankingProdDB.001) 91797 9/19/2018 4:00:50 AM 4 5 0 4664 9432 0 win-afvg9er8ckm nsrmmd NSR severe Unable to perform direct file save with Data Domain device 'DWHDD1_Digital_Banking_Prod_DB'; setting up traditional save for save-set ID '3600907418' (prdbsvr1:DB2:/PB_PROD/NODE0000) 71659 9/19/2018 7:44:12 AM 0 0 2 8440 1320 0 win-afvg9er8ckm nsrd NSR info prdbsvr1:DB2:/PB_PROD/NODE0000 done saving to pool 'Digital_Banking_Prod_DB' (DigitalBankingProdDB.001) 1358 GB 70896 9/19/2018 7:44:15 AM 0 0 2 8440 1320 0 win-afvg9er8ckm nsrd NSR info prdbsvr1:DB2:/PB_PROD/NODE0000 saving to pool 'Digital_Banking_Prod_DB' (DigitalBankingProdDB.001) 91797 9/19/2018 7:44:15 AM 4 5 0 4664 9432 0 win-afvg9er8ckm nsrmmd NSR severe Unable to perform direct file save with Data Domain device 'DWHDD1_Digital_Banking_Prod_DB'; setting up traditional save for save-set ID '2124525815' (prdbsvr1:DB2:/PB_PROD/NODE0000) Then we have check the connectivity between the client and DD vice versa. Connectivity is fine. And we are use the dedicated VLAN for the backup purpose. That means all the backup clients and DD are in the same range. How can we solve this issue. Pls advised. [/INST] Hi, Client here was Linux ppc64le and support for DDboost client direct backup was not introduced in NMDA until version 9.2 for this OS. Other linux x64 clients were also running 9.1.0.2 but the libraries required for DDboost were not present in the /usr/lib64 directories. There were also some other minor name resolution issues which need correcting to allow communication to be established. Running save -D 5 /etc/hosts on the Linux clients highlighted what the particular issues were on the hosts e.g. failing back to traditional backup as library not available, DD server not reachable etc. ppc64le/NMDA clients need NW 9.2 software installed - others with missing libraries we would also upgrade as its the same amount of work as deinstalling/reinstalling old version. name resolution and networking (ping/traceroute) checks also required to ensure connectivity can be established. Regards, </s>
<s>[INST] Hi I try to change a password for root user via openwsman util but it always returns error RAC011 "Job already exists Cannot process more Sets". The request: attributes.xml: The iDRAC response: I several times deleted all jobs with racadm: and reset iDRAC after that. It does not help. I performed reset the iDRAC to factory settings and it does not help too. But in the same time when I use racadm util or web interface I can change any settings successfully. iDRAC firmware version is 2.60.60.60, server model is R220. Could you help me to find reason why I can not configure drac with wsman? [/INST] Finally I found the solution. After command: any configuration requests via wsman perform successfully. </s>